the label attached to the lid), follow these steps:
a) replace the hose holder mounted on the appliance with
that supplied in the bag of "cooker accessories".
Important: the hose holder for liquid gas is marked 8, the
hose holder for methane gas is marked 13. Always fit the
sealing gasket.
b) Replacing the burner nozzles on the hob:
remove the grids and slide the burners from their
housings;
unscrew the nozzles using a 7 mm socket spanner, and
replace them with nozzles for the new type of gas (see
table 1 "Burner and nozzle characteristics").
replace all the components by repeating the steps in
reverse order.
Table 1
Burner
Diameter
(mm)
Fast
100
(Large)(R)
Semi Fast
75
(Medium)(S)
Auxiliary
55
(Small)(A)
Supply
Pressures
*
At 15°C and 1013 mbar- dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane
P.C.S. = 49,47 MJ/Kg
Natural
P.C.S. = 37,78 MJ/m
Burner and nozzle characteristics
Thermal Power
kW (p.c.s.*)
Nominal
Reduced
3.00
0.7
1.90
0.4
1.00
0.4
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
3
c) Minimum regulation of the hob burners:
turn the tap to minimum;
remove the knob and adjust the regulation screw, which
is positioned in or next to the tap pin, until the flame is
small but steady.
N.B.: in the case of liquid gas, the regulation screw must
be screwed in to the bottom.
check that the flame does not turn off when you turn the
tap quickly from high to low.
d) Regulating the primary air of the burners:
The primary air of the burners requires no regulation.
Important
On completion of the operation, replace the old rating sticker
with one indicating the new type of gas used. This sticker is
available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in compliance
with current National Regulations relative to "regulators for
channelled gas".
Liquid Gas
By-Pass
Nozzle
1/100
1/100
(mm)
(mm)
***
41
86
218
30
70
138
30
50
73
28-30
20
35
S
S
R
A
K 642 VS/G
K 642 V/G
6
Natural Gas
Flow*
Nozzle
g/h
1/100
**
(mm)
214
116
136
106
71
79
37
20
25
17
45
25
Flow*
l/h
286
181
95