KAI-2001/KAI-2020/KAI-2093 OPERATIONAL SETTINGS

The Imager board is configured to operate the KAI-2001/KAI-2020/KAI-2093 CCD image sensor under
the following operating conditions:

DC Bias Voltages

The following voltages are fixed, or adjusted with a
potentiometer as noted. The nominal values listed
in Table 3 correspond to the device specification
nominal settings at the time of this document's
publication, and are subject to change. The Min
Description
Output Gate
Reset Drain
Output Amplifier Supply
Alternate Amplifier Supply
Ground
Substrate
ESD Protection
Output Amplifier Return
NOTES:
1.
The recommended VSUB voltage is specified for each CCD image sensor, and is labeled on the device container as V

Clock Voltages

The following clock voltage levels are fixed, or
adjusted with a potentiometer as noted.
nominal values listed in Table 4 correspond to the
device specification nominal settings at the time of
this document's publication, and are subject to
Description
Horizontal CCD Clock Hxx_CCD
Vertical CCD Clock
Reset Clock
Fast Dump Clock
VDD
M T D / P S - 0 7 1 5
w w w . k o d a k . c o m / g o / i m a g e r s
KAI-2001/
KAI-2020
Symbol
Min
Nominal
OG
-5.0
-2.0
RD
7.0
12.0
VDD
15.0
ALT_VDD
6.0
-
GND
0.0
SUB
7.0
Vab
ESD
-6.0
-7.0
VSS
0.5
0.7

Table 3: DC Bias Voltages

Symbol
Level Min
Low
-7.5
High
-5.0
Vx_CCD
Low
-12.0
Vx_CCD
Mid
-3.0
V2_CCD
High
6.5
RESET_CCD
Low
-7.5
High
0.5
FD_CCD
Low
-11.0
High
2.5
+15V
High

Table 4: Clock Voltages

5 8 5 - 7 2 2 - 4 3 8 5
P a g e 7 o f 3 1
and Max voltages in the table indicate the
approximate adjustable voltage range on the
imager board.
specified CCD operating conditions.
appropriate device specifications for details.
KAI-2093
Nominal
Max Units
-2.5
-0.5
10.5
14.0
15.0
-
11.0
0.0
Vab
13.0
-7.0
-11.0
0.7
5.0
change. The Min and Max voltages in the table
The
indicate the approximate adjustable voltage range
on the imager board. These values may exceed
the specified CCD operating conditions. See the
appropriate device specification for details.
KAI-2001/
KAI-2020
KAI-2093
Nom
Nom
-4.0
-4.0
1.0
1.0
-9.0
-9.0
0.0
-1.5
8.0
8.0
-3.5
-3.5
1.5
1.5
-9.0
0.0
5.0
0.0
15.0
15.0
F a x : 5 8 5 - 4 7 7 - 4 9 4 7
These values may exceed the
Potentiometer
V
R26
V
R25
V
Fixed
V
R28
V
Fixed
V
R17
V
R27
V
R29
Potenti-
Max Unit
ometer Notes
-1.0
V
R146
5.0
V
R129
-6.5
V
R66
3.0
V
R107
12.0
V
R83
-1.0
V
R166
5.0
V
R158
-4.0
V
R108
5.0
V
R93
V
Fixed
R e v i s i o n 4 . 0
E m a i l : i m a g e r s @ k o d a k . c o m
See the
Notes
1
.
AB
1
2
3
4
5
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kai-2020Kai-2093

Table of Contents