Kai-2001/Kai-2020/Kai-2093 Imager Evaluation Board Description; Imager Board Input Requirements; Table 1: Power Requirements - Kodak KAI-2001 User Manual

Ccd image sensors imager evaluation board
Table of Contents

Advertisement

IMAGE SENSOR SOLUTIONS

KAI-2001/KAI-2020/KAI-2093 IMAGER EVALUATION BOARD DESCRIPTION

The
KAI-2001/KAI-2020/KAI-2093
Evaluation Board, referred to in this document as
the Imager Board, is designed to be used as part
of a two-board set, used in conjunction with a
Timing Generator Board. Kodak offers an Imager
Board / Timing Generator Board package that has
been designed and configured to operate with the
KAI-2001, KAI-2020, and KAI-2093 CCD image
sensors.
The Timing Generator Board generates the timing
signals necessary to operate the CCD, and
provides the power required by the Imager Board.
The timing signals, in LVDS format, and the
power, are provided to the Imager Board via the
interface connector (J4). In addition, the Timing
Generator Board performs the processing and
digitization of the analog video output of the
Imager Board.

IMAGER BOARD INPUT REQUIREMENTS

M T D / P S - 0 7 1 5
w w w . k o d a k . c o m / g o / i m a g e r s
Power Supplies
Minimum
+5V_MTR Supply
-5V_MTR Supply
VPLUS Supply
VMINUS Supply

Table 1: Power Requirements

5 8 5 - 7 2 2 - 4 3 8 5
Imager
The Imager Board has been designed to operate
the KAI-2001, KAI-2020, and KAI-2093 CCDs with
the specified performance at nominal operating
conditions. (See the appropriate performance
specifications for details).
For testing and characterization purposes, the
Imager board provides the ability to adjust many of
the CCD bias voltages and CCD clock level
voltages by adjusting potentiometers on the board.
The Imager Board provides the means to modify
other device operating parameters (e.g., CCD
reset clock pulse width) by populating components
differently on the board.
Some circuitry on the Imager Board (e.g., remote
DAC control of bias and clock level voltages) is
intended for Kodak test purposes only, and may
not be populated.
Typical
4.9
5
800
-5.1
-5
200
18
20
250
-21
-20
250
F a x : 5 8 5 - 4 7 7 - 4 9 4 7
P a g e 3 o f 3 1
Maximum
Units
5.1
V
mA
-4.9
V
mA
21
V
mA
-18
V
mA
R e v i s i o n 4 . 0
E m a i l : i m a g e r s @ k o d a k . c o m

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kai-2020Kai-2093

Table of Contents