Approved Vent Configurations

Overview

This appliance has several components used to control the flow of intake air and exhaust gases.
Depending upon vent configuration, you may be required to adjust the intake restrictor, exhaust restrictor,
diffuser and/or install the intake dampers and extender plate. Refer to the vent configuration (pages 18 to
23) to determine the correct restrictor, damper, extender, and diffuser settings.

Intake Restrictor

NOTE: Refer to the vent configuration (pages 18 to 23) to determine the correct restrictor position.

Intake Damper Plates

NOTE: Refer to the vent configuration (pages 18 to 23) to determine if these plates must be installed.
Two intake damper plates are included in the owner's pack. They are installed behind the burner in
certain vent configurations. See page 44 for details on removing the burner.