Troubleshooting
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless
testing requires power.

LED/Switch Check

While in Service Mode, pressing the Chime and
Wrinkle Prevent keys for 3 seconds, will start a
LED/Switch Test. To exit the test at any point, press
the same keys again for 3 seconds or press the OFF
key to exit Service Mode.
Perform the check by pressing the keys which toggle
the LED's on and off.
All switch pads must be pressed within 5 minutes for
this test to pass. PA will be displayed for five (5)
seconds once all switch pads have been pressed and
this test is completed. Following 10 seconds of
inactivity at any point, the test will exit without any
display. The
Power Off switch pad must be pressed
twice within thirty (30) seconds to cancel this test.
Switch
Action
Wrinkle Prevent
Press once
Chime
Press once
Adjust Time
Press once
Time
Press once
Temperature
Press once
Dryness Level
Press once
Selector Knob
Rotate 1 position
Start Pause
Press once
Off
Press once
Diagnostic Codes
The Diagnostic Codes are identified when the
severity level of the abnormality detected is higher
and service may be required.
When a problem with the dryer is detected a
Diagnostic Code is assigned, and can be displayed.
The Control Board will not log multiple same codes
per cycle; however, it will log as many Diagnostics as
possible for the machine to continue running.
Access Diagnostic Codes by entering the Service
Mode and pressing Wrinkle Prevent. A d will be
displayed.
Rotate the Cycle Selector Knob in either direction to
step through the list of codes one code at a time.
Once an initial direction is selected by the user (either
Clockwise or Counterclockwise), subsequent movements
of the knob in the same direction will show older codes.
If the user changes direction and turns the knob in the
opposite direction, the more recent code will be
displayed.
WARNING
While a diagnostic code is displayed, if the
Start/Pause button in the center of the Rotary Cycle
Selector is pressed and held, the machine will display
the number of cycles ago the diagnostic code
occurred. When the Start/Pause button is released,
the diagnostic code is again displayed.
Clearing Diagnostic Codes
To clear the diagnostic code list press the Sensor
Dry Level and Time keypads together for 3 seconds
while viewing the list. The cycle count for each
diagnostic code will be reset to 0, but not the machine
cycle count.