Troubleshooting Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect power to dryer before servicing, unless
testing requires power.

LED/Switch Check

While in Service Mode, pressing the Chime and
Wrinkle Prevent keys for 3 seconds, will start a
LED/Switch Test. To exit the test at any point, press
the same keys again for 3 seconds or press the OFF
key to exit Service Mode.
Perform the check by pressing the keys which toggle
the LED's on and off.
All switch pads must be pressed within 5 minutes for
this test to pass. PA will be displayed for five (5)
seconds once all switch pads have been pressed and
this test is completed. Following 10 seconds of
inactivity at any point, the test will exit without any
display. The Power Off switch pad must be pressed
twice within thirty (30) seconds to cancel this test.
Switch
Action
Wrinkle Prevent
Press once
Chime
Press once
Adjust Time
Press once
Time
Press four times
Temperature
Press twice
Dryness Level
Press twice
Selector Knob
Rotate 1 position
Start Pause
Press once
Off
Press once
Diagnostic Codes
The Diagnostic Codes are identified when the severity
level of the abnormality detected is higher and service
may be required.
When a problem with the dryer is detected a
Diagnostic Code is assigned, and can be displayed.
The Control Board will not log multiple same codes
per cycle; however, it will log as many Diagnostics as
possible for the machine to continue running.
Access Diagnostic Codes by entering the Service
Mode and pressing Wrinkle Prevent. A d will be
displayed.
Rotate the Cycle Selector Knob in either direction to
step through the list of codes one code at a time.
Once an initial direction is selected by the user (either
Clockwise or Counterclockwise), subsequent
movements of the knob in the same direction will
show older codes. If the user changes direction and
16026881
RPL 16026540
!
WARNING
turns the knob in the opposite direction, the more
recent code will be displayed.
While a diagnostic code is displayed, if the
Start/Pause button in the center of the Rotary Cycle
Selector is pressed and held, the machine will display
the number of cycles ago the diagnostic code
occurred. When the Start/Pause button is released,
the diagnostic code is again displayed.
Clearing Diagnostic Codes
To clear the diagnostic code list press the Sensor Dry
Level and Time keypads together for 3 seconds while
viewing the list. The cycle count for each diagnostic
code will be reset to 0, but not the machine cycle
count.
Diagnostic Codes
Code
1
2
3
4
4
Description
Trigger
Dryer
The
Thermistor
Thermistor
Short Sensed
resistance is
very low.
Thermistor
The
Open Sensed
Thermistor
resistance is
very high
Door Circuit
Invalid state
Failure
for more
than 256
milliseconds
Possible motor
If either
transistor error
motor
transistor is
seen open or
shorted
during
startup
Action Taken
Check for:
- Clogged lint
screen.
- Restricted vent
system.
- Check Thermistor
resistance.
Check for:
- Low ambient
temperature in
room (Below
º
º
50
F/10
C).
- Outside vent
damper is stuck
open in wintertime.
- Loose or open
wire terminals.
- Check Thermistor
resistance.
Check for:
- Loose or open
wire terminals in
Door Sense
circuit.
Check for:
- Loose connections
in motor circuit.
- Run System
Check Mode and
check the motor
relay function.
- If relay functions,
disregard the

diagnostic code.

- If relay does not
function, replace
machine control
board.