1. Screw the L-shape connector (4) into the pump housing (2) by rotating in a
clockwise direction (Fig. 10).
Note: Make sure the L-shape connector (4) is firmly tightened so that the
O-ring is compressed between the pump housing (2) and the L-shape connector
(4). This ensures no leakage will occur at this point.
2. Screw the prepared universal adaptor (3) clockwise onto the L-shape
connector (4) (hose/tube/tap adaptor should not be connected at this stage)
(Fig. 11).
Note: Make sure the universal adaptor (3) is firmly tightened so that the
O-ring of the L-shaped connector (4) is compressed between the universal adaptor
(3) and the L-shaped connector (4). This ensures no water or air leakage will occur
at this point.
3. Securely attach the hose/tube/tap adaptor (not included) to the universal
adaptor (3) (Fig. 12) (see the section "Preparing the Universal Adaptor").
Note: Due to the high water pressure generated by the pump it is recommended
to use a hose clamp (not included) when fitting a flexible hose or tube (available
from your local Bunnings Warehouse). This secures the hose or tube and further
prevents it from becoming removed from the universal adaptor (3) during operation
(Fig. 13).
Note: Before submerging the pump in water, unwrap the power cable (10)
and ensure the plug is clear of any damp locations.
4. To immerse the pump in deep water, use a rope (not included) and
secure it to the handle (1) (Fig. 14). Set the pump in the desired position
within the work area/tank.
Note: The vent valve (7) is used to allow air to escape from the pump body when
submerging the pump so no priming is required.