3.1 Identification Memory Programming

Identification memory programming is performed by the dealer before the phone is
supplied to the user.
Connect a LOCAL BOX with programming rights to the phone base connector, and
turn on the phone. Check that LOCAL is displayed, and enter 0#.

3.1.1 Program the Subscriber Number

For systems with i-specification capabilities:
Enter 2#, Z X1 X2 X3 X4 X5 X6 K1 K2 K3 and finally F.
Z = country code, and X1...X6 = six digit subscriber number, and K1...K3 =
phone identification number.
Other systems:
Enter 2#, Z X1 X2 X3 X4 X5 X6 and finally F.
Z = country code, X1...X6 = six digit subscriber number
The subscriber number length may also vary from system to system.
Enter 2* to verify successful programming.

3.1.2 Program the Password Code

Enter 3#, X1 X2 X3 X4 and finally F.
X1...X4 = user defined number series
Enter 3* to verify successful programming

3.1.3 Program the Serial Number

Enter 4#, a six digit serial number, and finally F.
e.g. 1 2 3 4 5 6
Enter 4* to verify successful programming

3.1.4 Program the Date of Sale

Enter 6#, the date of sale, and finally F.
The date of sale is given in the form ddmmyy e.g. 160194
Enter 6* to verify successful programming