- Local 0 #, 31 #, 23 #, 201 # 0
- Use the +/- keys to set the deviation to 600 (+/- 20) Hz, press F and C keys.
- Local 0 #.

5.0.13 DTMF Deviation Adjustment

- Local 0 #, 31 #, 21#, 203 #, choose 941 Hz with the +/- keys, and press the F
key.
- Local 201 # 8 and set the deviation with +/- keys to 1.80 (+ 0.20) kHz, press F
and C keys.
- Local 0 #.

5.0.14 Subscriber Number Programming

- Local 0 #, 2 #, enter 7 digit number (and 3 digit password if needed) and
press the f key.
- Check with 2 *.
- Local 0 #

5.0.15 Select Battery Type

- Local 95 #
- Use the +/- keys to select the battery type in use, and press the F key.
- Check with 95*