Set DA1 Audible Alarm (DA2 to DA6 similar), information includes (Fig. 33):
> Graphics DA1 and bEEP.
> Number of beeps (1 to 10), flashing upon access.
> Number of times the beeps are to repeat (1t to 3t, t = times).
• A (< 2 sec) - to step upward through the Beep set points from 1 to 10 one at a time.
• M (< 2 sec) - to step back through the Beep set points one at a time.
• S (2 sec) - to step back to Depth digits flashing.
• S (< 2 sec) - to save the Beep setting and flash the t (number of times) digit.
• A (< 2 sec) - to step upward through the t (times) set points from 1t to 3t one at a time.
• M (< 2 sec) - to step back through the t (times) set points one at a time.
• S (2 sec) - to step back to Beep digits flashing.
• S (< 2 sec) - to save the Audible setting (digits solid) and flash the graphic SEt allowing ON or OFF to be selected/saved..
------------------------------------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------------------------------------------
SET UTILITIES
Sequence: Lead-in >> Units >> Wet Activ >> Water Type >> Backlight Duration >> Auto Glo >> Sampling Rate >> DSD >> BDSI.
• A (< 2 sec), while viewing Set Alarms Lead-in, to access Set Utilities Lead-in.
The Wet Activation feature allows you to disable activation of Dive Mode during activities when you only want to use the Watch
features and don't want diving information displayed or recorded.
The Water Type selection determines Depth calibration to accomodate activities in fresh or sea/salt water.
The Backlight Duration determines how long the Backlight will be On when activated by pressing the Light (L) button.
When Auto Glo is set On, the Backlight will activate automatically upon entry into Dive Mode and remain On until the BDSI time (up
to 1 min) elapses after surfacing. L button operation of the Backlight will be disabled during the dive, then enabled on the surface.
Sampling Rate determines the interval at which data is sampled and recorded for upload to the Computer Interface program. It
does not affect the rate at which data is measured for the display (which is at fixed 1 second rate).
The DSD (Dive Start Depth) feature allows you to select the Depth at which Dive Mode will be activated upon descent. Regardless
of the DSD set, every dive ends upon ascent above 2 FT (0.6 M) for the BDSI set.
The BDSI (Between Dive Surface Interval) feature allows you to select the time interval between surfacing and descending that
determines whether the descent is a new dive. Short intervals may be preferred for some activities and longer intervals for others,
thus a selection may be helpful.
At any time while entering settings -
• M (2 sec), or 2 minutes of no button action, will revert to SURF MAIN.
• L (< 2 sec) - to toggle the Backlight On/Off. Will be On for the duration time set.
• L (2 sec), while the Backlight is On, - to reset the timer to keep it On for the full duration time set.
Set Utilities Lead-in, information includes (Fig. 34):
> Graphics Go To SEt - U.
• S (< 2 sec) - to access Set Units.
• A (< 2 sec) - to step forward to ID-SN.
• M (< 2 sec) - to step back to Set Alarms Lead-in.
Set Units, information includes (Fig. 35):
> Graphic UNIT.
> FT icon and °F (or M and °C), flashing.
• A or M (< 2 sec) - to toggle between Imperial (FT, F) and Metric (M, C).
• S (2 sec) - to step back to Set Utilities Lead-in.
• S (< 2 sec) - to save the setting and access Set Wet Activation.
© 2002 Design, 2013
18
F11 OPERATING MANUAL
Fig. 33 - SET DA AUDIBLE
Fig. 34 - SET UTILITIES
Fig. 35 - SET UNITS
Doc. No. 12-7285-r01 (5/3/13)