Voltage; Connections Scheamtic - Fagor “TOUCH CONTROL” Instruction Manual

Touch control vitroceramic hobs
Table of Contents

Advertisement

CONNECTIONS SCHEAMTIC

The vitro-ceramic hotplate is supplied with a power cable.
If the power feed wire is damaged, it must be replaced by the manufacturer, by
the after-sales service or by authorized personnel for safety reasons.
If the type of connections to which the hotplate is to be installed is other than
220 to 240 V AC remove the cable and make the connection according to the
adjacent drawings. (The cable must support temperatures of up to 120ºC).
The hotplate must be connected to the mains with a plug that meets the EEC 7
publication or with a multi-pole switch with a distance between the open
contacts of a least 3mm.
Total power
Hotplate: 60 cms., 6,3kW, Hotplate: 75 cms., 7,4 kW
PLATE

Voltage

60 cms 220...240V~ 27,5 A
75 cms 220...240V~
PLATE
Voltage
60 cms 380...400V~
75 cms 380...400V~
This device conforms to European dirctives 73/23/CEE and 89/336/CEE
Protection
Int.nominal
by phases
32 A
32 A
32 A
Three phase
Protection
Int.nominal
by phases
11 A
12 A
13 A
16 A
70
Three phase
Voltage
Int.nominal
by phases
220...240V~
14 A
220...240V~ 16,5 A
Voltage
Int.nominal
by phases
380...400V~
16 A
380...400V~
19 A
Protection
16 A
20 A
Protection
20 A
20 A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents