Dc-Ac Inverter (Option) - Furuno CSH-8L Installation Manual

Color scanning sonar
Hide thumbs Also See for CSH-8L:
Table of Contents

Advertisement

2. WIRING
2.7

DC-AC Inverter (option)

Use the JIS (Japan Industrial Standard) cable DPYCY-6 or equivalent (max. 5 m) between
the ship's mains and the DC/AC inverter. For output (100 VAC), use JIS (Japan Industrial
Standards) cable DPYCY-4 or equivalent (max. 50 m).
DPYCY-4:
DPYCY-6:
2-20
15.9 mm
17.4 mm
Conductor
DPYCY-4: S = 4 mm ,
DPYCY-6: S = 6 mm ,
10
80
Wind vinyl tape.
Fix armor to the clamp.
Fabricating JIS cable DPYCY-4, DPYCY-6
Armor
Vinyl sheath
2
2.55 mm
2
3.12 mm
FV5.5-6
(DC input: Local supply)
FV5.5-4
(AC output:Local supply)