Transducer Cable Extension Kit (Option) - Furuno CSH-8L Installation Manual

Color scanning sonar
Hide thumbs Also See for CSH-8L:
Table of Contents

Advertisement

2.6

Transducer Cable Extension Kit (option)

The upper side of the cable clamp holds the transducer cable; the lower side the cable
connected to the transceiver unit. Terminals for the transducer are numbered from the left
side from 1 to 14. On the IN side of the circuit board, connect the cables from the
transducer. Connect the cable to the transceiver to the OUT side. Fix even-numbered
cables with cable clips.
Fix transducer cable (10S1943) at lower cable clamp.
XCB
P3
10P6865
P2
P1
TRX1
IN OUT
P2
P1
P3
IN OUT
Note 1: Plug in connectors firmly and fix cables with cable clips. Connectors may become
disconnected and interference may result if this is not done before replacing the
cover.
Note 2: Note that P1 and P2 connectors share the same shape and same pin number.
Note 3: If false echoes appear after installation, check connectors and the junction box.
Fix cable (10S1950) connected to transceiver
unit at upper cable clamp.
Junction box, side view
Cable clip
TRX2
TRX4
TRX6
TRX3
TRX5
IN OUT
IN OUT
IN OUT
IN OUT
View from cable clamp
Junction box
TRX8
TRX10
TRX9
TRX7
TRX11
IN OUT
IN OUT
IN OUT
IN OUT
IN OUT
2. WIRING
TRX14
TRX12
TRX13
IN OUT
IN OUT
IN OUT
2-19

Hide quick links: