2. WIRING
2.3.1
Transducer cable wiring
Separate the cable in two, pass it through cable clamp [A] and fix it with a cable tie. Pass
the cable through cable clamp [B] and fix with cable tie. Pass cable through cable clamp at
the side of the transceiver unit.
Fix by cable clamp.
(See Note 1.)
Note 1: Wire unit with cable clamps in horizontal position. Lay cable clamp after finishing
wiring.
Clamp base
Bolts
Note 2: When fixing transducer cable with cable clamp, wrap with vinyl tape before fixing, or
wrap the cable with a piece of the outer sheath of the cable and fix by cable clamp.
2-6
Cable clamp [A]
Transceiver unit, upper view
Clamp
Cable clamp
Cable clamp [B]
Fix by two cable ties.
Transducer cable
Cable clamp
(See Note 2.)
(Can be placed
on left side.)
1. Lay braided shields of transducer cable in
cable clamp. Each cable is numbered;
connect referring to the illustration on the
preceding page.
2. Unfasten two bolts.
3. Set the clamp and fasten it with two
bolts removed at step 2.