HEATING SPECIFICATIONS
Model: *SZ140421A* / CA*F4860*6A*+TXV / MBR2000**-1
Conditions: 1400 CFM Indoor Air @ 70°F DB
Basic U nit without
Outdoor
Auxiliary Heat
Ambient
capacity
°F.
btuh
c.o.p.
65
51.54
4.44
60
48.79
4.28
55
45.92
4.11
50
42.93
3.92
45
39.73
3.70
40
36.90
3.50
35
34.03
3.30
30
34.27
3.26
25
31.63
3.08
20
29.12
2.90
15
26.48
2.70
10
23.76
2.48
5
21.07
2.25
0
18.37
2.01
-5
15.68
1.76
-10
12.84
1.48
*To obtain BTU capacity of unit with KW of auxiliary heat, multiply by 1000 (Example: 39.01 x 1000 = 39,010 BTU)
24
Capacity of U nit*
With KW of Auxiliary heat
4.8
9.6
14.4
67.92
84.30
100.68
117.07
65.17
81.55
97.94
114.32
62.30
78.68
95.07
111.45
59.31
75.69
92.07
108.46
56.11
72.49
88.88
105.26
53.28
69.66
86.05
102.43
50.41
66.79
83.18
50.65
67.03
83.41
48.01
64.39
80.77
45.50
61.89
78.27
42.86
59.25
75.63
40.14
56.52
72.91
37.45
53.83
70.21
34.75
51.13
67.52
32.06
48.44
64.82
29.22
45.61
61.99
Model: *SZ140601A* / CA*F4860*6A*+TXV / MBE2000**-1
Conditions: 1850 CFM Indoor Air @ 70°F DB
Basic U nit withou t
Outdoo r
Auxiliary Heat
Amb ient
capacity
°F.
btuh
c.o.p.
71.65
4.34
65
67.83
4.19
60
55
63.84
4.03
50
59.68
3.85
55.23
3.64
45
40
51.30
3.45
47.31
3.26
35
47.86
3.17
30
25
44.17
2.99
20
40.68
2.83
15
36.99
2.63
10
33.19
2.43
5
29.42
2.21
25.66
1.98
0
-5
21.90
1.74
-10
17.94
1.46
Model: *SZ140481A* / CA*F4860*6A*+TXV / MBR2000**-1
Conditions: 1550 CFM Indoor Air @ 70°F DB
Basic U nit without
Outdoor
Auxiliary Heat
Ambient
capacity
°F.
btuh
19.2
65
57.82
60
54.74
55
51.52
50
48.16
44.57
45
40
41.40
35
38.18
99.56
30
36.62
99.79
33.80
97.15
25
94.65
20
31.12
92.01
15
28.30
89.29
25.39
10
86.59
5
22.51
83.90
0
19.63
81.20
16.75
-5
78.37
13.72
-10
Cap acity of U nit*
With KW of Auxiliary h eat
4.8
9.6
14.4
88.03
104.41
120.80
84.21
100.59
116.98
80.22
96.60
112.99
76.06
92.44
108.83
71.62
88.00
104.38
67.68
84.06
100.45
63.69
80.07
96.46
64.24
80.63
97.01
60.56
76.94
93.32
57.06
73.44
89.83
53.37
69.76
86.14
49.57
65.95
82.34
45.81
62.19
78.57
42.04
58.42
74.81
38.28
54.66
71.04
34.32
50.70
67.09
GSZ140[42-60]1A*
Capacity of U nit*
With KW of Auxiliary heat
c.o.p.
4.8
9.6
4.25
74.20
90.59
106.97
4.10
71.12
87.50
103.89
3.94
67.90
84.28
100.67
3.76
64.54
80.93
97.31
3.55
60.96
77.34
93.72
3.36
57.78
74.16
90.55
3.17
54.56
70.94
87.33
2.94
53.00
69.38
85.76
2.77
50.18
66.56
82.94
2.61
47.50
63.89
80.27
2.43
44.68
61.06
77.45
2.24
41.77
58.16
74.54
2.03
38.89
55.28
71.66
1.82
36.01
52.40
68.78
1.59
33.13
49.52
65.90
1.34
30.11
46.49
62.87
19.2
137.18
133.36
129.37
125.21
120.76
116.83
112.84
113.39
109.70
106.21
102.52
98.72
94.95
91.19
87.43
83.47
19.2
14.4
123.35
120.27
117.05
113.69
110.10
106.93
103.71
102.15
99.32
96.65
93.83
90.92
88.04
85.16
82.28
79.25