Control Protocol And Baud Rate - Vidia PTZ User Manual

Dome camera
Table of Contents

Advertisement

5.4
Control protocol and baud rate must be set correctly to the camera in order to
establish proper communication between the camera and control device.
Be sure that the same protocol and baud rate are selected in control device, too.
Presently 2 types of protocol and 3 levels of baud rate are provided by this speed
dome, through an 8-bit DIP switch labeled DS1.
DS 1
First, installer needs to choose a communication protocol with bit number 3, 4
and 5. Watch that the same protocol is chosen for speed dome and controller.
The following table shows the three protocols provided in this speed dome.
Check what are available in the controller before choosing the protocol.
Bit 1 and 2 are for baud rate setup. Same baud rate must be set up for the
speed dome and control device, or communication for control will fail.
Vidia Srl – Via Vasanello 23, 00189 Roma – Tel +39 0630316333 Fax +39 0630350231 www.vidia.it

Control Protocol and Baud Rate

remark:
A.
B.
C.
D.
E.
F.
3
4
5
--
--
--
on
--
--
--
on
--
on
on
--
1
2
--
--
on
--
--
on
"--" means to set the bit to "OFF" position
Bit 1 and 2 are for baud rate setup
Bit 3, 4 and 5 are for protocol selection
Bit 6 is reserved future use
Bit 7 is for firmware upgrade mode
Bit 8 is for cooling fan on / off switching
Protocol
Pelco-D
Pelco-P
Reserved
Reserved
Baud rate
2,400 bps
4,800 bps
9,600 bps

Advertisement

Table of Contents
loading

Related Products for Vidia PTZ

This manual is also suitable for:

PtPtz/pt dome camera

Table of Contents