Clearances; Sr-10 Clearances - Empire Heating Systems SR-6-3 Installation Instructions And Owner's Manual

Unvented room heater
Table of Contents

Advertisement

Available languages

Available languages

When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.
Left side 6 inches (152mm). Right side 6 inches 152mm).
Do not install in alcove or closet.
Rear wall 0 (0mm) inches. Ceiling 24 inches (610mm).
Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 10 inches (254mm).
Maximum horizontal extension of projection above the appliance 12 inches (305mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and proper operation must be provided.
24" MIN
(610mm)
WINDOW SILL OR SHELF
10" MIN
(254mm)
6" MIN
(152mm)
2" MIN
(51mm)
Figure 3 (SR-6)
When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.
Left side 6 inches (152mm). Right side 6 inches (152mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 24 inches (610mm).
Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 14 inches (356mm).
Maximum horizontal extension of projection above the appliance 12 inches (305mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and proper operation must be provided.
Page 8
SR-6 CLeARAnCeS
CEILING
SIDE WALL
6" MIN
(152mm)
FLOOR

SR-10 CLeARAnCeS

CEILING
WINDOW SILL OR SHELF
24" MIN
(610mm)
10" MIN
(254mm)
SIDE VIEW
2" MIN
(51mm)
FLOOR
Figure 4 (SR-6)
12" MAX
(305mm)
0" (0mm) CLEARANCE
TO REAR WALL
16942-7-1009