Performance Data Sheet - Kenmore 106.5116 Use & Care Manual

Elite side by side refrigerator
Hide thumbs Also See for 106.5116:
Table of Contents

Advertisement

Available languages

Available languages

Model P5WB2L/P4RFKB2/P4RFKB12 Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50% reduction
*
Particulate Class I
85% reduction
Contaminant
NSF Reduction
Reduction
Requirements
Live Cysts
99.95%
Asbestos
99%
Lead: @ pH 6.5
0.010 mg/L
Lead: @ pH 8.5
0.010 mg/L
Lindane
0.0002 mg/L
Toxaphene
0.003 mg/L
Atrazine
0.003 mg/L
2,4 - D
0.07 mg/L
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
It is important that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised. Property damage can occur if all
instructions are not followed.
Use replacement filter P4RFKB2/P4RFKB12, part #9930.
2012 suggested retail price of $49.99 U.S.A./
$59.99 Canada. Prices are subject to change without notice.
Style 1 – When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter
indicator reads "REPLACE," it is recommended that you
replace the filter.
Style 2 – When the filter indicator changes from green to
yellow, order a new filter. When the indicator changes from
yellow to red, it is recommended that you replace the filter.
Style 3 – When the filter indicator reads 10%, order a new
filter. When the indicator reads 0%, it is recommended that
you replace the filter.
After changing the water filter, flush the water system. See
"Water and Ice Dispensers."
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
*
Class I particle size: >0.5 to <1 um
**
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
Based on the use of Cryptosporidium parvum oocysts
††
Fibers greater than 10 um in length
® NSF is a registered trademark of NSF International.
34

PERFORMANCE DATA SHEET

Water Filtration System
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, and Particulate
Class I*; and against NSF/ANSI Standard 53 for the reduction of Live
Cysts, Asbestos, Lead, Lindane, Toxaphene, Atrazine, and 2,4 - D.
Average
Influent Challenge
Influent
Concentration
2.0 mg/L
2.0 mg/L ± 10%
7,300,000 #/mL
At least 10,000 particles/mL
Average
Influent Challenge
Influent
Concentration
160,000/L
50,000/L min.
7
87 MFL
10
to 10
0.160 mg/L
0.15 mg/L ± 10%
0.140 mg/L
0.15 mg/L ± 10%
0.0019 mg/L
0.002 mg/L ± 10%
0.014 mg/L
0.015 mg/L ± 10%
0.0094 mg/L
0.009 mg/L ± 10%
0.220 mg/L
0.210 mg/L ± 10%
Maximum
Effluent
0.20 mg/L
75,000 #/mL
Maximum
Effluent
54/L
8
††
fibers/L
0.17 MFL
0.001 mg/L
0.005 mg/L
0.00002 mg/L
0.001 mg/L
0.0005 mg/L
0.028 mg/L
The water system must be installed in compliance with state
and local laws and regulations.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be
used on disinfected waters that may contain filterable cysts.
Refer to the "Warranty" section in this Use & Care Guide
for the Manufacturer's name, address and telephone
number.
Refer to the "Warranty" section in this Use & Care Guide
for the Manufacturer's limited warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Minimum %
Average %
Reduction
Reduction
97
97.2
**
99
99.4
Minimum %
Average %
Reduction
Reduction
99.97
99.99
99
99
99.4
99.4
98.6
98.6
98.9
99
93
93
94.5
94.7
87.5
96.1
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 Lpm) @ 60 psi

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents