Heat Exchanger; Fan Motor - Toshiba RAS-07PKVP-E Service Manual

Split type
Hide thumbs Also See for RAS-07PKVP-E:
Table of Contents

Advertisement

High Wall, Heat Pump Type

11-1-6. Heat Exchanger

1) Perform all the steps in 11-1-1.Removing the
Front Panel and Moving Panel and 11-1-2.
Fixing Frame Assembly.
2) Remove the pipe holder at the rear of the unit.
3) Remove the two fixing screws (10 mm) at the
left of the heat exchanger.
4) Remove the fixing screw of the heat exchanger
fixing holder (upper).
5) Remove the fixing screw of the heat exchanger
fixing holder (lower).
6) Release the end plate hook and the claw at the
right of the heat exchanger, pull up the heat
exchanger, and then remove the fixing holder
(lower) from the guide of the indoor unit.
Screw
(10 mm)
Heat exchanger
fixing holder
(upper)
CAUTION
Check that the claw is engaged with the end plate hook,
and then secure the heat exchanger with screws.

11-1-7. Fan Motor

Pipe holder
Heat exchanger
fixing holder
(lower)
97
1) Perform all the steps in 11-1-1.Removing the
Front Panel and Moving Panel and 11-1-3.
Electric Parts Cover Detached.
2) Loosen the hexagon socket set screw of the
cross flow fan from the air outlet.
3) Remove the two fixing screws of the motor
band (right).
4) Pull the motor band (right) and the fan motor
out of the unit.
Hexagon socket set screw
Motor band (right)
Motor connector
Positioning ribs
CAUTION
Install the fan motor while positioning it so that the fan
motor connector comes between the positioning ribs on
the motor band (right).
Be sure to tighten the hexagon socket set screw so that
it touches the D-cut surface of the fan motor shaft.
Service Manual
Fixing screws
Motor band (right)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents