Electrical Work - Toshiba RAS-07PKVP-E Service Manual

Split type
Hide thumbs Also See for RAS-07PKVP-E:
Table of Contents

Advertisement

High Wall, Heat Pump Type
5 mm dia. hole
[5] Mounting screw
Clip anchor
(local parts)
CAUTION
Failure to securely install the unit may result in personal
injury and/or property damage if the unit falls.
• In case of block, brick, concrete or similar type walls,
drill 5 mm dia. holes in the wall.
• Insert clip anchors for the [5] mounting screws.
NOTE
Install the installation plate using between 4 to 6
mounting screws, making sure all four corners are
secure.

9-3-3. Electrical Work

• The supply voltage must be the same as the rated
voltage of the air conditioner.
• Prepare a power source for the exclusive use of the
air conditioner.
NOTE
• Wire type: H07RN-F or 60245IEC66 (1.0 mm
• Make sure the wire length is sufficient before
performing wiring work.
9-3-4. Wiring Connection
Connecting cable (Wiring the connecting
cable can be carried out without removing the
front panel.)
1) Pull the handles on the bottom of the right and
left sides, and open the moving panel until it is
horizontal.
2) Remove the terminal cover and cord clamp.
3) Insert the connecting cable (or as according to
local regulations/codes) into the pipe hole on
the wall.
4) Pull the connecting cable through the cable slot
on the rear panel so that it protrudes about 15
cm out of the front.
Anchor bolt
Projection 15 mm or less
Dia. 4 × 25L
2
5) Insert the connecting cable fully into the
terminal block and secure it tightly with screws.
Make a loop with the earth wire under the
terminal block and secure it with the earth
screw.
6) Tightening torque: 1.2 N·m (0.12 kgf·m)
7) Secure the connecting cable with the cord
clamp.
8) Attach the terminal cover and moving panel on
the indoor unit.
• Be sure to refer to the wiring system diagram labelled
inside the front panel.
• Check local electrical regulations for any specific
wiring instructions or limitations.
Terminal cover
Screw
Screw
Cord clamp
)
Connecting cable
about 15 cm
61
Service Manual
CAUTION
Terminal block
Earth wire
Connecting cable
Terminal block
Earth wire(loop)
Earth screw
110 mm
10 mm
10 mm
50 mm
Earth line

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents