Outdoor Unit Control - Toshiba RAS-07PKVP-E Service Manual

Split type
Hide thumbs Also See for RAS-07PKVP-E:
Table of Contents

Advertisement

High Wall, Heat Pump Type
Precautions when attaching the inverter box
View from behind
Partition board

11-3-4. Outdoor Unit Control

P.C. Board
1) Disconnect the leads and connectors
connected between the control P.C. board
assembly and other parts.
Insert the heat insulator into
the gap of the partition board.
Hook the
inverter fixing
plate to the
partition board.
Link up the slit of
the partition board
with the boss of the
inverter box.
103
Insert the bent portion at
the lower part of the
inverter box into the gap
of the partition board.
NOTE
When leads are clamped with cable ties, cut the cable
ties.
Leads connected to terminal: Disconnect the 3P
connector (black/white/orange).
Leads connected to compressor: Disconnect the 3P
connector.
Leads connected to reactor: Disconnect the two 2P
connectors.
Earth lead (black): Remove the screw.