Python 950 Installation Manual page 39

Car security
Hide thumbs Also See for 950:
Table of Contents

Advertisement

default (tach wire connected) setting. If programmed to the voltage sense setting, the unit will crank the starter
for a preset time that can be programmed in Feature 2-5. Once the starter has been engaged, the system will check
the voltage level to verify the engine is running. The threshold for the voltage level test can be programmed in
Feature 2-6. When using voltage sense mode, connection of the H3/5 WHITE tachometer input is not necessary.
2-3 RUN TIME 12/24/60 MINUTES: This feature controls how long the engine will run before it "times out" and
shuts down. Programmed to the default setting the engine will run for 12 minutes. If the 24-minute run time is
desired, change this feature to the on-board LED off setting.
2-4 FLASHING PARKING LIGHT OUTPUT: In the default setting, the unit will flash the vehicle's parking lights
while remote started. The constant setting will turn the parking lights on solidly for the entire run duration.
2-5 CRANKING TIME 0.6/0.8/1.0/1.2/1.4/1.6/1.8/2.0/4.0: If feature 2-2 is programmed to the voltage sense
setting, the crank time must be set to the appropriate duration. The default setting is 0.6 seconds. If a different
crank time is desired, select feature 2.5 and (while pressing the Valet/Program switch) advance to the next time
by pressing the channel 2 button. The unit will flash the LED to indicate which time is selected. Once the 4.0
second setting is reached the next press of channel 2 will reset the system to the shortest setting.
2-6 VOLTAGE CHECK LEVEL HIGH/LOW: This feature only functions when Feature 2-2 is programmed to voltage
sense. Some vehicles have many accessories, which are turned on when remote started. In these vehicles, the
variation of voltage between the engine off and the vehicle running is very slight and the remote start unit may
"think" the vehicle has not started. This can cause the remote start to shut down after the vehicle has been
started. If this is the case, program this feature to the LOW position.
2-7 SHORT RUN (TURBO TIMER): When the
and
buttons on the transmitter are pressed simulta-
neously, the vehicle will continue to run for the programmed short-run time. The factory default is 1 minute.
2-8 ACTIVATION PULSE COUNT: This feature allows the number of pulses to activate the remote start feature to
be changed from 1, 2, or 3 pulses. The pulse count programmed to start the vehicle will also be the same required
to shut down the remote start.
2-9 2 nd IGNITION/ACCESSORY OUTPUT: This will allow the PINK/WHITE to be used as a 2 nd ignition or an acces-
sory.
2-10 ACCESSORY STATE DURING WAIT-TO-START: This will allow the programming of the accessory wire during
the wait-to-start period of a diesel motor. When ON the accessory comes on when the wait-to-start output is acti-
vated and stays on, dropping out during crank and returning once the car has started. When OFF the accessory
will activate as a normal accessory.
2-11 2 nd STATUS OUTPUT: This status will activate 10 seconds after the car has started. It is intended to operate
the defogger circuit. The output can be programmed to a latched or a pulsed output. When programmed to the
latched output the status will only stay active for 10 minutes.
39
© 2006 Directed Electronics—all rights reserved

Advertisement

Table of Contents
loading