Summary of Contents for Witura WT-1672B
Page 1
VERSION: 1.2 UPDATED: AUG 2013 WT‐1672B GSM Wireless Alarm System USER MANUAL WITURA TECHNOLOGY SDN BHD | WT‐1672B GSM Wireless Alarm System User Manual V2.0 ...
Page 2
SETTING UP AND PROGRAMMING When first booting up the system you will see Green LED Lights on the side of the Enclosure and it should light up when the Network is applied to the unit. The Green LED is the network Indicator and this will light up when attempting to log on to the network flash inconsistently until it locates the network. A Phone Call to the SIM Card Number will now Latch the Relay permanently ON and Switch the device being Controlled On. The Status of the Relay will remain as on, until the unit receives a second Call to the Unit of which will now Latch the Relay Permanently off. Both Calls used to Latch the Relay either on or off are automatically disconnected, once the relays are activated and never incur any Network Call Costs. Beside calls to switch off or on, the unit also can be permanently switch off and on by sending the unit a text message command WITURA TECHNOLOGY SDN BHD | WT‐1672B GSM Wireless Alarm System User Manual V2.0 ...
Page 3
Step 1 ‐ The simplest set up methods to set up Administrator number Applied the “KISS Principle”, keep it simple, stupid. The GSM Remote Control Switch is easy to setup and use. Insert the SIM card, simply use your mobile phone call to the unit, your mobile phone number will automatically register as the 1st Administrators You will receive the following SMS message from the unit – Administrator: 1: 18617185300 (your phone number) 2: 3: 4: 5: You already finish the set up. Now, you can use your mobile phone call to the SIM Card number switch the device on permanently. Another call to the SIM Card will switch the device off permanently. If you do not required to go through details setting, please process to STEP3 – Final Installation and Wiring WITURA TECHNOLOGY SDN BHD | WT‐1672B GSM Wireless Alarm System User Manual V2.0 ...
Page 4
This means you already reset the unit to factory default. Now you can start to call again to set the administrator. This method of setting is only allowed to set 1 administrator number. If you wish to set more administrators, please go to Step 3 – Installation and set up WITURA TECHNOLOGY SDN BHD | WT‐1672B GSM Wireless Alarm System User Manual V2.0 ...
Page 5
You can add up to 5 telephone number into the admin list. 4 Check phone number you *2* Administrator: program in the list 1: 15989427391 2: 18617185300 3: 4: 5: 2013019019 16:09 Thu 5 Delete the admin number in the list. *3*N# Administrator: Delete Admin Number 1: 15989427391 Delete 1st admin *3*1# N = Admin number 1‐ 5 2: Delete 2nd admin *3*2# For example, if you want to 3: Delete 3rd admin *3*3# delete admin no 2. 4: Delete 4th admin *3*4# just enter *3*2# 5: Delete 5th admin *3*5# 2013019019 17:16 Thu WITURA TECHNOLOGY SDN BHD | WT‐1672B GSM Wireless Alarm System User Manual V2.0 ...
Page 6
N = 1 to 9 (N is numbering of the system 1: channel in the list of Wireless 2:73c708 Alarm in the system) 3:73c702 4:73c701 For example, if you want to 5: delete list no 1.just enter *7*1# 6: 7: 8: 9: 2013‐10‐10 16:16 Thu 10 Checking the Remote Control List *8* Controller: After sending *8*, you will get that already added to the system 1:373f00 the list of the remote Control list 2: that already added to the system 3: 4: 5: 2013‐10‐10 16:18 Thu WITURA TECHNOLOGY SDN BHD | WT‐1672B GSM Wireless Alarm System User Manual V2.0 ...
Page 7
LED light in the system will turn on. All the function such as Outage Alarm, Temperature Report, Line Alarm, Startup system, 9 Channel Wireless Alarm will function. 13 Checking the status of the Alarm *11* Alarm switch<ON> Check the status of the alarm Function in the system function in the system 2013‐10‐10 16:29 Thu WITURA TECHNOLOGY SDN BHD | WT‐1672B GSM Wireless Alarm System User Manual V2.0 ...
Page 8
Privacy and Security before you decide to 2013‐10‐10 17:13 Thu use the Open Mode Factory Default is N=1 for Security Mode 17 SMS Text Message to Switch On/Off *24*N# When Setting as N=1 means switch on the relay Relay *24*1# by SMS Message Master relay <ON> N=0 means switch off the relay by SMS Message 2013‐10‐10 17:13 Thu When Setting as *24*0# Master relay <OFF> 2013‐10‐10 17:13 Thu WITURA TECHNOLOGY SDN BHD | WT‐1672B GSM Wireless Alarm System User Manual V2.0 ...
Page 9
NN =10 means Edit for Input When Setting as Alert Message for line cut alert *26*01*The door closed!# XXXXXXX is the text messages Wireless 1 defined content which can up to 70 information: The door alphabet. When the text closed! message content successfully programmed, it will overwrite 2013‐10‐10 17:21 Thu the system default text messages WITURA TECHNOLOGY SDN BHD | WT‐1672B GSM Wireless Alarm System User Manual V2.0 ...
Page 10
NN=10 means Delete Input Alert Message for line cut alert Master relay <OFF> 2013‐10‐10 17:45 Thu If there is no text message programmed, it will return a SMS with Blank Message When Setting as *28*01# Delete OK! 2013‐10‐10 17:42 Thu After delete success, when the 1st channel wireless alarm trigger, admin will receive the default text message Alarm 1.Please timely processing! 2013‐10‐10 17:45 Thu WITURA TECHNOLOGY SDN BHD | WT‐1672B GSM Wireless Alarm System User Manual V2.0 ...
Page 11
If Admin Numbers has been programmed, all the admin number will receive the SMS Message of the Pairing wireless alarm equipment location. When hear 3 TIT sound, means the 9 wireless alarm equipment already FULL. You need to delete some command then only can continue to do pairing process WITURA TECHNOLOGY SDN BHD | WT‐1672B GSM Wireless Alarm System User Manual V2.0 ...
Page 12
Connection Details If you are unsure how to connect the device you wish to control refer to a qualified person Connector 1 2 3 4 5 6 7 8 Board Label 12V IN LINE 5V OUT RELAY 12V Dry Power Relay Description Power Contact Outage Output Supply Input Alarm Details + ‐ + ‐ WITURA TECHNOLOGY SDN BHD | WT‐1672B GSM Wireless Alarm System User Manual V2.0 ...
Page 13
Example Wireless And Wireless Sensor with WT‐1672B Production Specifications Operation Voltage 12 volts DC Operating Current Maximum 500mA, typically 55mA Relay Contacts 2amps GSM Frequency MHz GSM900/1800Mhz, or GSM850/900/1800/1900Mhz Humidity Less Than 80% RH Operating Temperature ‐20c to 55c Physical Size 6.8cm x 4.1cm x 12.5cm Protection IP 65 Weather Proof Casing Approvals C.E, FCC, ETSI WITURA TECHNOLOGY SDN BHD | WT‐1672B GSM Wireless Alarm System User Manual V2.0 ...
Page 14
After successfully registering the SIM card, ensure there is sufficient credit on the card for programming confirmation texts to be sent from the GSM Remote Control Switch. You MUST ensure that the PIN request is disabled from the SIM card before inserting it into the GSM Remote Control Switch. If you do not disable the PIN request the GSM Remote Control Switch will not work. If the PIN request is not disabled and the unit is switched on more than 3 times you will have to reset the PIN using the PUK code which will have to be obtained from the service provider. To check the PIN request status of your SIM card, place the card in an unlocked mobile phone, switch the phone on. If you are able to make calls without entering a PIN number the PIN request is disabled. If a PIN number is requested refer to the instructions supplied with the SIM card and then look through the phones options for the ‘disable PIN request’ and disable it. You MUST disable any voicemail that is set up on the SIM card; the codes shown below are for UK networks only, please refer to your network operator if outside the UK Vodafone: 1210 >Send ‐ you will hear ‘order is accepted and confirmed’ O2 ‐ Call 1760 >Send ‐ you will hear ‘order is accepted and confirmed’ T‐Mobile ‐ Call 222 and follow instructions Orange ‐ Call 450 and follow instructions The SIM card is now ready to use We recommend that if you are using a ‘pay as you go’ (PAYG) SIM card that you choose to automatically ‘Top‐ Up’ when the cards credit falls below a certain limit please contact your network provider or visit their website for more details. Most but not a using post‐paid SIM cards will be de‐activated by the network if not used to make an outgoing voice call or send an SMS text message within a specific period. To prevent this simply send the GSM Remote Control Switch a text command *0*PW#, then *2*, it will reply by text message, do this once a month to keep the SIM card active. WITURA TECHNOLOGY SDN BHD | WT‐1672B GSM Wireless Alarm System User Manual V2.0 ...
4. I am not receiving any text messages when once every 3 seconds (see 2 above). Ensure the SIM initially programming the unit card has credit Most but not all PAY SIM cards will be de‐activated by the network if not used to make an outgoing voice call 5. The unit has been working for several months or send an SMS text message within a specific period. and has now stopped responding to calls and To prevent this simply send a txt command *0*PW#, text commands then *2*, it will reply by text message, do this once a month to keep the SIM card active WITURA TECHNOLOGY SDN BHD | WT‐1672B GSM Wireless Alarm System User Manual V2.0 ...
Warranty Witura Technology Sdn Bhd warrantees the WT‐1672B GSM Wireless Alarm System against defective parts and workmanship. Witura Technology Sdn Bhd shall, at its option, repair or replace the defective equipment upon the return of such equipment to any Witura branch. This warranty applies ONLY to defects in components and workman‐ship and NOT to damage due to causes beyond the control of Witura, such as incorrect voltage, lightning damage, mechanical shock, water damage, fire damage, or damage arising out of abuse and improper application of the equipment. Note: Wherever possible, return only the PCB to Witura Service Centres. DO NOT return the enclosure. The WT‐1672B is a product of Witura Technology Sdn Bhd And is manufactured by Shenzhen Witura Telecommunications Co., Ltd. WARNING For safety reasons, only connect equipment with a telecommunications compliance label. This includes customer equipment previously labelled permitted or certified. WITURA TECHNOLOGY SDN BHD | WT‐1672B GSM Wireless Alarm System User Manual V2.0 ...