WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0
 
WT‐1672B 
GSM Wireless Alarm System 
 
USER MANUAL 
VERSION: 1.2
UPDATED: AUG 2013 
 
 
1

Advertisement

loading

Summary of Contents for Witura WT-1672B

  • Page 1   VERSION: 1.2   UPDATED: AUG 2013          WT‐1672B  GSM Wireless Alarm System        USER MANUAL                  WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0  ...
  • Page 2 SETTING UP AND PROGRAMMING     When first booting up the system you will see Green LED Lights on the side of the Enclosure and it should light  up when the Network is applied to the unit.    The Green LED is the network Indicator and this will light up when attempting to log on to the network flash  inconsistently until it locates the network.    A Phone Call to the SIM Card Number will now Latch the Relay permanently ON and Switch the device being  Controlled On.    The Status of the Relay will remain as on, until the unit receives a second Call to the Unit of which will now  Latch the Relay Permanently off.    Both  Calls  used  to  Latch  the  Relay  either  on  or  off  are  automatically  disconnected,  once  the  relays  are  activated and never incur any Network Call Costs.    Beside calls to switch off or on, the unit also can be permanently switch off and on by sending the unit a text  message command        WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0  ...
  • Page 3 Step 1 ‐ The simplest set up methods to set up Administrator number           Applied the “KISS Principle”, keep it simple, stupid.     The GSM Remote Control Switch is easy to setup and use. Insert the SIM card, simply use your mobile phone  call to the unit, your mobile phone number will automatically register as the 1st Administrators    You will receive the following SMS message from the unit –     Administrator:  1: 18617185300 (your phone number)   2:   3:  4:  5:     You already finish the set up.  Now, you can use your mobile phone call to the SIM Card number switch the  device on permanently. Another call to the SIM Card will switch the device off permanently.     If you do not required to go through details setting, please process to STEP3 – Final Installation and Wiring      WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0  ...
  • Page 4 This  means  you  already  reset  the  unit  to  factory  default.  Now  you  can  start  to  call  again  to  set  the  administrator.      This method of setting is only allowed to set 1 administrator number. If you wish to set more administrators,  please go to Step 3 – Installation and set up                                                    WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0  ...
  • Page 5 You  can  add  up  to  5  telephone  number into the admin list.    4  Check phone number you  *2*   Administrator:     program in the list   1: 15989427391  2: 18617185300  3:  4:  5:    2013019019 16:09 Thu  5  Delete the admin number in the list.    *3*N#  Administrator:  Delete Admin Number      1: 15989427391  Delete 1st admin  *3*1#   N = Admin number 1‐ 5    2:   Delete 2nd admin *3*2#   For example, if you want to  3:  Delete 3rd admin *3*3#  delete admin no 2.  4:  Delete 4th admin *3*4#  just enter *3*2#  5:  Delete 5th admin *3*5#    2013019019 17:16 Thu  WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0  ...
  • Page 6 N = 1 to 9 (N is numbering of  the system  1:  channel in the list of Wireless  2:73c708  Alarm in the system)  3:73c702    4:73c701  For example, if you want to  5:  delete list no 1.just enter *7*1#  6:  7:  8:  9:    2013‐10‐10 16:16 Thu  10  Checking the Remote Control List  *8*  Controller:  After  sending  *8*,  you  will  get  that already added to the system  1:373f00  the list of the remote Control list  2:  that already added to the system  3:  4:  5:    2013‐10‐10 16:18 Thu  WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0  ...
  • Page 7 LED  light  in  the  system  will  turn  on.  All  the  function  such  as  Outage  Alarm,  Temperature  Report,  Line  Alarm,  Startup  system,  9  Channel  Wireless  Alarm will function.  13  Checking the status of the Alarm  *11*  Alarm switch<ON>  Check the status of the alarm  Function in the system    function in the system  2013‐10‐10 16:29 Thu              WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0  ...
  • Page 8 Privacy  and    Security  before  you  decide  to  2013‐10‐10 17:13 Thu  use  the  Open  Mode   Factory  Default  is  N=1  for  Security Mode  17  SMS Text Message to Switch On/Off  *24*N#  When Setting as  N=1 means switch on the relay  Relay  *24*1#  by SMS Message  Master relay <ON>  N=0 means switch off the relay    by SMS Message  2013‐10‐10 17:13 Thu    When Setting as  *24*0#  Master relay <OFF>    2013‐10‐10 17:13 Thu  WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0  ...
  • Page 9 NN  =10  means  Edit  for  Input  When Setting as  Alert Message for line cut alert  *26*01*The door  closed!#  XXXXXXX  is  the  text  messages  Wireless 1 defined  content  which  can  up  to  70  information: The door  alphabet.  When  the  text  closed!   message  content  successfully    programmed,  it  will  overwrite  2013‐10‐10 17:21 Thu  the  system  default  text  messages  WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0  ...
  • Page 10 NN=10  means  Delete  Input    Alert Message for line cut alert  Master relay <OFF>      2013‐10‐10 17:45 Thu  If  there  is  no  text  message    programmed,  it  will  return  a    SMS with Blank Message  When Setting as  *28*01#  Delete OK!    2013‐10‐10 17:42 Thu    After delete success,  when the 1st channel  wireless alarm trigger,  admin will receive the  default text message  Alarm 1.Please timely  processing!    2013‐10‐10 17:45 Thu  WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0  ...
  • Page 11 If  Admin  Numbers  has  been  programmed,  all  the  admin  number  will  receive  the  SMS  Message of the Pairing wireless  alarm  equipment  location.  When hear 3 TIT sound, means  the 9 wireless alarm equipment  already  FULL.  You  need  to  delete  some  command  then  only can continue to do pairing  process              WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0  ...
  • Page 12 Connection Details   If you are unsure how to connect the device you wish to control refer to a qualified person    Connector  1  2  3  4  5  6  7  8  Board Label  12V IN  LINE  5V OUT  RELAY  12V  Dry  Power  Relay  Description  Power  Contact  Outage  Output  Supply  Input  Alarm  Details     +  ‐         +  ‐        WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0  ...
  • Page 13 Example Wireless And Wireless Sensor with WT‐1672B    Production Specifications   Operation Voltage    12 volts DC   Operating Current   Maximum 500mA, typically 55mA   Relay Contacts   2amps  GSM Frequency MHz   GSM900/1800Mhz, or GSM850/900/1800/1900Mhz   Humidity   Less Than 80% RH   Operating Temperature   ‐20c to 55c  Physical Size  6.8cm x 4.1cm x 12.5cm   Protection   IP 65 Weather Proof Casing   Approvals  C.E, FCC, ETSI               WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0  ...
  • Page 14 After  successfully  registering  the  SIM  card,  ensure  there  is  sufficient  credit  on  the  card  for  programming  confirmation texts to be sent from the GSM Remote Control Switch.  You MUST ensure that the PIN request is disabled from the SIM card before inserting it into the GSM Remote  Control Switch. If you do not disable the PIN request the GSM Remote Control Switch will not work. If the PIN  request is not disabled and the unit is switched on more than 3 times you will have to reset the PIN using the  PUK code which will have to be obtained from the service provider.  To check the PIN request status of your SIM card, place the card in an unlocked mobile phone, switch the  phone on. If you are able to make calls without entering a PIN number the PIN request is disabled. If a PIN  number is requested refer to the instructions supplied with the SIM card and then look through the phones  options for the ‘disable PIN request’ and disable it.  You MUST disable any voicemail that is set up on the SIM card; the codes shown below are for UK networks  only, please refer to your network operator if outside the UK  Vodafone: 1210 >Send ‐ you will hear ‘order is accepted and confirmed’  O2 ‐ Call 1760 >Send ‐ you will hear ‘order is accepted and confirmed’  T‐Mobile ‐ Call 222 and follow instructions  Orange ‐ Call 450 and follow instructions  The SIM card is now ready to use  We recommend that if you are using a ‘pay as you go’ (PAYG) SIM card that you choose to automatically ‘Top‐ Up’ when the cards credit falls below a certain limit please contact your network provider or visit their website  for more details.  Most but not a using post‐paid SIM cards will be de‐activated by the network if not used to make an outgoing  voice call or send an SMS text message within a specific period. To prevent this simply send the GSM Remote  Control Switch a text command *0*PW#, then *2*, it will reply by text message, do this once a month to keep  the SIM card active.    WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0  ...
  • Page 15: Troubleshooting

    4. I am not receiving any text messages when  once  every  3  seconds  (see  2  above).  Ensure  the  SIM  initially programming the unit  card has credit  Most but not all PAY SIM cards will be de‐activated by  the network if not used to make an outgoing voice call  5. The unit has been working for several months  or send an SMS text message within a specific period.  and has now stopped responding to calls and  To  prevent  this  simply  send  a  txt  command  *0*PW#,  text commands  then *2*, it will reply by text message, do this once a  month to keep the SIM card active              WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0  ...
  • Page 16: Warranty

      Warranty    Witura Technology Sdn Bhd warrantees the WT‐1672B GSM Wireless Alarm System against defective  parts and workmanship. Witura Technology Sdn Bhd shall, at its option, repair or replace the defective  equipment upon the return of such equipment to any Witura branch. This warranty applies ONLY to  defects in components and workman‐ship and NOT to damage due to causes beyond the control of  Witura, such as incorrect voltage, lightning damage, mechanical shock, water damage, fire damage, or  damage arising out of abuse and improper application of the equipment.    Note: Wherever possible, return only the PCB to Witura Service Centres.  DO NOT return the enclosure.        The WT‐1672B is a product of  Witura Technology Sdn Bhd  And is manufactured by  Shenzhen Witura Telecommunications Co., Ltd.        WARNING  For safety reasons, only connect equipment with a telecommunications compliance label. This    includes customer equipment previously labelled permitted or certified.   WITURA TECHNOLOGY SDN BHD |                                WT‐1672B GSM Wireless Alarm System User Manual V2.0  ...