Witura WT-1010SA User Manual

Standalone gsm alarm system

Advertisement

W
T
-
W
T
-
S
T
A
N
D
-
A
L
O
N
S
T
A
N
D
-
A
L
O
N
S
T
A
N
D
-
A
L
O
N
User Manual
1
0
1
0
1
0
1
0
E
G
S
M
A
L
A
R
M
E
G
S
M
A
L
A
R
M
E
G
S
M
A
L
A
R
M
S
A
S
A
S
Y
S
T
E
M
S
Y
S
T
E
M
S
Y
S
T
E
M
W
I
T
U
W
I
T
U
W
I
T
U
R
A
C
O
R
P
O
R
A
T
I
O
N
S
D
R
A
C
O
R
P
O
R
A
T
I
O
N
S
D
R
A
C
O
R
P
O
R
A
T
I
O
N
S
D
N
B
H
D
N
B
H
D
N
B
H
D

Advertisement

Table of Contents
loading

Summary of Contents for Witura WT-1010SA

  • Page 1 User Manual...
  • Page 2 Connector Block The antenna must be well connected before Back-up when Power Failure All wiring must be connected turn on the terminal here Connection Diagram WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 3: Table Of Contents

    Power adapter Lithium-Ion Back-up Battery 5m GSM terminal antenna User’s Manual Contents 1. Introduction to WT-1010SA GSM Alarm System………………………………………………………………….….5 2. Main Features of the WT-1010SA….………….………………………………………………………………………..……5 3. Installation Instruction....................6 3.1 Description……………………………………………………………………………………………………………………………………………..6 3.2 WT-1010SA Inputs & Outputs Wiring Instructions……………………………………………………………………………...7 3.3 Installing the SIM Card………………………………………………………………………………………………………………………….8 3.4 Power up the WT-1010SA…………………………………………………………………………………………….……………………….8...
  • Page 4 WT-1010SA USER MANUAL 6. Miscellaneous Settings…………………………………………………………………………….………………………….….32 7. Technical Specifications ....................... WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 5: Introduction To Wt-1010Sa Gsm Alarm System

    When no telephone service is available from your home, it ensures that critical alarm information reaches the central station. The WT-1010SA uses a GSM communicator, no distance limits to receive alarm calls or remote control the alarm system, it can also call and sends text alerts to 8 pre-set telephone number when intruder alarm triggers.
  • Page 6: Installation Instruction

    3.1) Description 1. Antenna: connect the antenna to the GSM module; place the antenna as far as possible from the WT-1010SA and do not leave any coiling of the antenna cable to avoid radiant interference 2. SIM Card: disable the PIN code and set it to 1234 (default)
  • Page 7: Wt-1010Sa Inputs & Outputs Wiring Instructions

    SMS with a certain command. Note: When sending normal SMS with command below, the WT-1010SA will turn On / Off the output relay and reply a message of output has turned On / Off to a programmable phone numbers.
  • Page 8: Installing The Sim Card

    Battery WT-1010 Note: Whenever the WT-1010SA fails to logon to network or fails to detect the SIM card, it will restart automatically until it has detected the SIM card or successfully logon to network. WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com...
  • Page 9: Dialing A Number From The Attached Telephone Set

    (try to keep it as far as possible from the WT-1010SA unit antenna). Usually it is possible to find a suitable location for the phone with minimal level of interference.
  • Page 10: Wt-1010Sa Configuration Instructions (Via Voice)

    4. WT-1010SA Programming Instructions (Via Fixed Line Phone) 4.1 Introduction The WT-1010SA can be programmed manually by a connected normal telephone. Note: Before commencing programming it is advisable to read the below programming setting instructions thoroughly. To start with programming, user must...
  • Page 11: Step2- Reset The Wt-1010Sa Unit

    ON&OFF: 1 Then press 1# to reset REST ON&OFF: 1 Note: It is advised that you should reset the WT-1010SA unit before proceeding to the below programming section Programming the Administrator Number Step 3. Continue pressing *1* to start programming the administrator number 1...
  • Page 12: Step4- Setting The Recipient That Will Receive Alert Messages

    1 – 8. Default Value: 10000000 Programming the Area Code Step 5. To program area code, you can press *9* to proceed. NEW AREA: WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 13: Step6- Setting The Function Of Adding Area Code When Transmitting An Alarm

    Default Value: 0 Setting the Delay Time for Transmitting a Dialing Number Step 7. To set the delay time, you can press *34* to proceed. DTTRANSMIT: WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 14: Step8- Setting For Calling A Group Of Administrator Numbers

    Simply press 5# CALL: 5 Setting for Auto Test Step 9. 9.1) Time Setting To setup time, you can press *16* to proceed. TIME: WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 15 The time is entered in 24 Hour format. To program the auto test report time section 2, you can press *42* to proceed. WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 16 Simply input digits and ended with # DSTM3: 23 : 59 : 00 Note: Skip this setting if only 1 time section is needed. WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 17 ON&&OFF: 1 Default Value: 0 Note: Please refer to programming instructions via SMS for editing the message content of Auto Test on page 26 WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 18: Step10- Setting For Pstn Failure

    PIN8 output which will remain available for the period of PSTN unavailable. Note: PSTN Failure Output facility can be used on alarm panel for alert notification WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 19: Step11- Setting For Ac Failure

    +5V output continuously supplied from the battery backup via PIN9 output of the unit which will remain available for the period of AC unavailable. Note: Power Down Output facility can be used on alarm panel for alert notification WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 20: Step12- Setting For Overcoming Gsm Jammers & Gsm Tower Failure

    Example: To set the network failure time for 5 seconds and the turn on time of Relay 1 for 5 seconds Simply press 0505# NETDT1: 05 RLY1: 05 WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 21 Example: To set the network failure time for 6 seconds and the turn on time of Relay 2 for 10 seconds Simply press 0610# WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 22: Step13- Input Settings

    “CA1” stands for calling the administrators when input triggered (open). Default: 0 “CA2” stands for calling the administrators when input triggered (close). Default: 0 Value: ON (1) or OFF (0) WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 23: Step14- Arm And Disarm The System

    ARM OR DISARM ON&&OFF: 1 System armed successfully Note: In Armed mode, the WT-1010SA can generate SMS alerts, alarms and dialing the administrator numbers when the inputs triggered, Auto Test, PSTN failed or AC failed. Alarm Indicator (When dialing the Administrator numbers):...
  • Page 24: Step15- Enable The Remote Control

    Remote Control Step 15. Enable The WT-1010SA also comes with a RF remote control. It allows you to arm or disarm the system easily from a close distance. To enable the remote control, you can press *45* to proceed.
  • Page 25: Step16- Setting The Automatic Call Answering Feature

    Setting the Automatic Call Answering Feature Step 16. The WT-1010SA can be programmed to answer all incoming calls automatically even there is no fixed line phone attached to it. When the call is answered, it allows the owner to arm or disarm the system by entering a command from their phone’s keypad.
  • Page 26: Wt-1010Sa Configuration Instructions (Via Sms)

    WT-1010SA USER MANUAL WT-1010SA Programming Instructions (Via SMS) Programming the WT-1010SA can also be done via SMS commands using your phone. Any programming command sent by SMS must be in CAPITAL letters. The fields between square brackets are parameters; do NOT enter the square brackets.
  • Page 27: Editing The Input Alert Messages (When High Pulse)

    SMS message to the unit. Note: Only support normal abc/ABC English text, no special characters. Text Command: *USC[N]#XXXXXX… N stands for Input number 1 – 4 WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 28: Output Settings

    SMS message to the unit. *RLY2#03600 Return Message *RLY2#=03600 Sending the following SMS Message to unit would mean turn off the output relay number 1. *RLY1#00000 WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 29: Arm And Disarm The System (Via Sms)

    To arm the system, you can send the following text message to the unit. *DARM#1 Return Message To disarm the system, you can send the following text message to the unit. *DARM#0 Return Message DISARM WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 30 Simply press # to delete DEL1: Changing the Programming Mode Password via Voice To change the 6 digits programming mode password, you can press *0* to proceed. WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 31 In the event the administrator has not answered the call or engaged, it could take a while for the WT-1010SA to call the next number. You can shorten the time for every call by programming the waiting time. Press *12* to proceed.
  • Page 32 Simply input 30 and ended with # Note: The Arm Time is a 2 digits value range from 00 – 59 seconds (Default: 00 seconds) WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 33 WT-1010SA USER MANUAL Enable/Disable System Power Up SMS Notification The system is able to generate SMS notification whenever the WT-1010SA is turned on. To enable this function, you can press *48* to proceed. POWER UP MSG ON&&OFF: POWER UP MSG ON&&OFF: 1...
  • Page 34 *51* to proceed. IN2D TIME: IN2D TIME: 60 Example: To set the alarm reporting delay time for 60ms Simply input 60 and ended with # WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 35 Setting the Alarm Time for Audible Alarm via Voice To set the alarm time for audible alarm, you can press *33* to proceed. ALARM: WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 36 Setting the WT-1010SA to ignore the front dialing digits when dialing the Administrator number via Voice This function is useful when the WT-1010SA is connected to the PABX system where Access Digits are required for Extension Line/Centrex Line. To set the unit to ignore the front dialing digits, you can press *44* to proceed.
  • Page 37 Note: Both SPK and MIC volume level range from 1 – 4 (Default: 1). Adjust the speaker and microphone volume to compatible with your alarm panel Inquire the Software and Hardware Version of WT-1010SA via Voice To check the software and hardware version of WT-1010SA unit, you can press *13* to proceed. HW: 1.1ver SW: 4.7 ver MW: 1.3ver...
  • Page 38 Changing the Programming Mode Password via SMS It is possible to change the login password by sending the following SMS command. Text Command: *PAWO#XXXXXX WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 39 X stands for ON (1) or OFF (0) value When *ALNF#1 is applied, means audible alarm will sound. When *ALNF#0 (Default) is applied, means audible alarm will turn off. WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 40 WT-1010SA USER MANUAL Reset the WT-1010SA unit via SMS To reset the unit, you can send the following command by SMS to the unit. Text Command: *REST#XXXXXX XXXXXX stands for 6 digits password based on *PAWO# (Default: 123456) and it can be changed anytime.
  • Page 41 Stability of frequency: better than 2.5PPM Signal sensitivity: -103dBM Transmit power: <2w Power: 220v±15% AC 10. Input Voltage Tolerances: 1~20VDC The max distance between terminal and telephone: 100M WT1010SA – USER MANUAL – Rev.1.6 – Technical Support: Technical@witura.com COPYRIGHT ©2009 WITURA CORPORATION SDN BHD...
  • Page 42: Wt1010Sa – User Manual – Rev.1.6 – Technical Support: Technical@Witura.com

    Terminal against defective parts and workmanship. Witura Corporation Sdn Bhd shall, at its option, repair or replace the defective equipment upon the return of such equipment to any Witura branch. This warranty applies ONLY to defects in components and workman-ship and NOT to damage due to...

Table of Contents