Witura WT-1010C2 User Manual

Gsm alarm system
Hide thumbs Also See for WT-1010C2:
Table of Contents

Advertisement

Quick Links

W
T
-
1
0
W
T
-
1
0
G
S
M
A
L
A
R
M
G
S
M
A
L
A
R
M
G
S
M
A
L
A
R
M
User Manual
1
0
C
2
1
0
C
2
S
Y
S
T
E
M
S
Y
S
T
E
M
S
Y
S
T
E
M
W
I
T
U
R
A
C
O
R
P
O
R
A
T
I
O
W
I
T
U
R
A
C
O
R
P
O
R
A
T
I
O
W
I
T
U
R
A
C
O
R
P
O
R
A
T
I
O
N
S
D
N
B
H
D
N
S
D
N
B
H
D
N
S
D
N
B
H
D

Advertisement

Table of Contents
loading

Summary of Contents for Witura WT-1010C2

  • Page 1 User Manual...
  • Page 2: Table Of Contents

    Step 12.1 Enable/Disable the Function of Activate Output Relay 1 when GSM Jammers is detected ……………………………………………………………………………………………………………………24 Step 12.2 Setting the Parameter for Network Failure………………………………………………………………24 WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 3 7.10 Activate Output Relay to Stay On for a Specific Time via Voice………………………………………………………….38 7.11 Setting the Alarm Time for Audible Alarm via Voice……………………………………………………………………………….38 7.12 Setting the WT-1010C2 to Ignore the Front Digits When Dialing th e Administrator via Voice……………………………………………………………………………………………………………………………………………………………………39 7.13 Adjusting the Speaker and Microphone Volume via Voice……………………………………………………………………39 7.14 Inquire the Software and Hardware Version of WT-1010C2 via voice………………………………………………40...
  • Page 4: Getting Started

    INDICATOR (RED) (GREEN) The indicator is illuminated when mains The indicator is power is present illuminated when the terminal is connected to GSM Network WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 5: Introduction To Wt-1010C2 Gsm Alarm System

    GSM cell phone network to communicate with the receiver at the monitoring station and transmit the alarms. 2.1. GENERAL OVERVIEW WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 6: Main Features Of The Wt-1010C2

    2. Works over the GSM cell phone networks Units can be used wherever there is cell phone coverage 3. Telephone line backup: WT-1010C2 give priority to the lowest cost network. WT- 1010C2 uses the telephone line as the main transmission line and uses the GSM voice channel as backup 4.
  • Page 7 For example, Zone 3 connected to an electric door, when there is intruder or the electric door is open illegally, WT-1010C2 will receive short circuit impulse on Zone 3 and automatically sends a signal to the pre-set number and notify the owner.
  • Page 8: Installation Instructions

    Turn On or Off the Connect a 12V Power Terminal Supply to the Terminal antenna to the Terminal 4. 2 Wiring Diagram A (Main Unit) WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 9: Wiring Diagram B (Db15 Female Cable)

    Description 1. Antenna: connect the antenna to the GSM module; place the antenna as far as possible from the WT-1010C2 and do not leave any coiling of the antenna cable to avoid radiant interference 2. SIM Card: disable the PIN code and set it to 1234 (default)
  • Page 10: Wt-1010C2 Inputs & Outputs Wiring Instructions

    SMS with a certain command. Note: When sending normal SMS with command below, the WT-1010C2 will turn On / Off the output relay and reply a message of output has turned On / Off to a programmable phone numbers.
  • Page 11: Installing The Sim Card

    There is a permanent +V output when the WT-1010C2 is power on. This output is available on the connection PIN8 and ground on the main board. The output voltage is according to power supply used on WT-1010C2. It can be used to power on other facility or device.
  • Page 12: Power Up The Wt-1010C2

    WT-1010 Battery Note: Whenever the WT-1010C2 fails to logon to network or fails to detect the SIM card, it will restart automatically until it has detected the SIM card or successfully logon to network. Dialing a number from the attached telephone set After the GSM module is connected to the GSM network, an attached fixed line phone can be used to make calls.
  • Page 13: Wt-1010C2 Configuration Instructions (Via Fixed Line Phone)

    If the noise is disturbing, change the location of the phone set (try to keep it as far as possible from the WT-1010C2 unit antenna). Usually it is possible to find a suitable location for the phone with minimal level of interference.
  • Page 14: Step2- Reset The Wt-1010C2 Unit

    ON&OFF: 1 Then press 1# to reset REST ON&OFF: 1 Note: It is advised that you should reset the WT-1010C2 unit before proceeding to the below programming section Programming the Administrator Step 3. Continue pressing *1* to start programming the administrator number 1 TEL: WT-1010C2 –...
  • Page 15: Step4- Setting The Recipient That Will Receive Alert Messages

    Note: The input for this setting is an 8 digits value: ON (1) or OFF (0) only. Each of them represents administrator 1 – 8. Default Value: 10000000 WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 16: Step5- Programming The Area Code

    ON&&OFF: 1 To turn on this function simply press 1# To turn off this function simply press 0# AREA ON&&OFF: 1 Default Value: 0 WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 17: Step7- Setting The Delay Time For Transmitting A Dialing Number

    *29* to proceed. CALL: CALL: 5 Example: Setting the unit to dial the first 5 administrator Simply press 5# CALL: 5 WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 18: Step9- Setting For Auto Test

    12 : 00 : 00 Example: To set the auto test report time at 12.00pm Simply input digits and ended with # DSTM1: 12 : 00 : 00 WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 19: Step 9.3 Setting The Auto Test Report Time Section 2

    Example: To set the auto test report time at 23.59 pm Simply input digits and ended with # DSTM3: 23 : 59 : 00 WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 20: Auto Test

    ON&&OFF: 1 To turn on this function simply press 1# To turn off this function simply press 0# DTIMEM ON&&OFF: 1 Default Value: 0 WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 21: Step 9.7 Setting The Burst On And Burst Off Time Of Dtmf Tones

    Value: 3 stands for 50~60ms Value: 4 stands for 60~80ms Value: 5 stands for 80~100ms Warning! The WT-1010C2’s Contact ID Protocols are complied with the Digital Communication Standard of Ademco. You are advised to go through the Digital Communication Standard here www.smartelectron.ru/files/DC-05_Contact_ID.pdf before proceed with this setting.
  • Page 22: Step10- Setting For Pstn Failure

    In additional to the alarm and text alert on PSTN failure the system also has a permanent +V output continuously supplied from the unit via PIN15 output which will remain available for the period of PSTN unavailable. WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 23: Step11- Setting For Ac Failure

    In additional to the alarm and text alert on AC failure the system also has a second permanent +V output continuously supplied from the battery backup via PIN7 output of the unit which will remain available for the period of AC unavailable. WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 24: Step12- Setting For Overcoming Gsm Jammers & Gsm Tower Failure

    To turn off this function simply press 0# NETWORK ON&&OFF: 1 Step 12.2 Setting the Parameter for Network Failure To set the parameter, you can press *39* to proceed. NETDT1: RLY1: WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 25: Step 12.3 Enable/Disable The Function Of Activate Output Relay 2 When Gsm Tower Failure

    To turn off this function simply press 0# NO SIGNAL ON&&OFF: 1 Step 12.4 Setting the Parameter for GSM Tower Failure To set the parameter, you can press *41* to proceed. WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 26: Step13- Input Settings

    Example: Setting the input 1 to generate an SMS, call the administrators and sound the audible alarm when it triggered. Simply input 11111# IN1: OP: 1 CL: 1 AL: 1 CA1: 1 CA2:1 WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 27: Step14- Arm And Disarm The System (Via Fixed Line Phone)

    ARM OR DISARM ON&&OFF: 1 System armed successfully Note: In Armed mode, the WT-1010C2 can generate SMS alerts, alarms and dialing the administrator numbers when the inputs triggered, Auto Test, PSTN failed or AC failed. Alarm Indicator (When dialing the Administrator numbers):...
  • Page 28: Step15- Setting The Automatic Call Answering Feature

    Setting the Automatic Call Answering Feature Step 15. The WT-1010C2 can be programmed to answer all incoming calls automatically even there is no fixed line phone attached to it. When the call is answered, it allows the owner to arm or disarm the system by entering a command from their phone’s keypad. To turn on this function, you can press *35* to proceed.
  • Page 29: Wt-1010C2 Programming Instructions (Via Sms)

    This happens because the WT-1010C2 recognizes any GSM number as administrator and answers to it. Warning! The administrator number must be programmed into the WT-1010C2 unit first via voice mode in order to use SMS programming mode.
  • Page 30: Editing The Message Contents Of Auto Test

    SMS message to the unit. Note: Only support normal abc/ABC English text, no special characters. Text Command: *USE[N]#XXXXXX… WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 31: Editing The Input Alert Messages (When No Pulse)

    To activate the output relay, you can send a text command via SMS specifying the number of seconds the output should stay on to the unit. It is possible to set up to maximum of 99,999 seconds WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 32: Activate Output Relay To Stay On Indefinitely

    N stands for Output number 1 - 3 For example, to switch off output relay number 2, you would send the following SMS message to the unit. *RLY2#OFF WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 33: Arm And Disarm The System (Via Sms)

    To arm the system, you can send the following text message to the unit. *DARM#1 Return Message To disarm the system, you can send the following text message to the unit. *DARM#0 Return Message DISARM WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 34: Miscellaneous Settings

    Simply press # to delete DEL1: 7.3 Changing the Programming Mode Password via Voice To change the 6 digits programming mode password, you can press *0* to proceed. WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 35: Inquire The Status Of The Recipients That Will Receive Alert Messages Via Voice

    In the event the administrator has not answered the call or engaged, it could take a while for the WT-1010C2 to call the next number. You can shorten the time for every call by programming the waiting time. Press *12* to proceed.
  • Page 36: Setting Arm Delay Time (Input 1 Only)

    Simply input 30 and ended with # Note: The Arm Time is a 2 digits value range from 00 – 59 seconds (Default: 00 seconds) WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 37: Enable/Disable System Power Up Sms Notification

    WT-1010C2 USER MANUAL 7.8 Enable/Disable System Power Up SMS Notification The system is able to generate SMS notification whenever the WT-1010C2 is turned on. To enable this function, you can press *46* to proceed. POWER UP MSG ON&&OFF: POWER UP MSG ON&&OFF: 1...
  • Page 38: Activate Output Relay To Stay On For A Specific Time Via Voice

    Example: To set the audible alarm to sound for 1 hour when triggered Simply press 03600# ALARM: 03600 Note: The alarm time must enter in 5 digits range from 00001 – 99999 (Default: 00010 seconds) WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 39: Setting The Wt-1010C2 To Ignore The Front Digits When Dialing Th E Administrator Via Voice

    7.12 Setting the WT-1010C2 to ignore the front dialing digits when dialing the Administrator via Voice This function is useful when the WT-1010C2 is connected to the PABX system where Access Digits are required for Extension Line/Centrex Line. To set the unit to ignore the front dialing digits, you can press *44* to proceed.
  • Page 40: Inquire The Software And Hardware Version Of Wt-1010C2 Via Voice

    Note: Both SPK and MIC volume level range from 1 – 4 (Default: 1). Adjust the speaker and microphone volume to compatible with your alarm panel 7.14 Inquire the Software and Hardware Version of WT-1010C2 via Voice To check the software and hardware version of WT-1010C2 unit, you can press *13* to proceed. HW: 1.1ver SW: 1.0 ver MW: 1.5ver...
  • Page 41: Checking The Current Time Status Via Sms

    To reset the unit, you can send the following command by SMS to the unit. Text Command: *REST#XXXXXX XXXXXX stands for 6 digits password based on *PAWO# (Default: 123456) and it can be changed anytime. WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 42: Inquire The Status Of Inputs, Pstn And Ac

    7. Signal sensitivity: -103dBM 8. Transmit power: <2w 9. Power: 220v±15% AC 10. Input Voltage Tolerances: 1~20VDC 11. The max distance between terminal and telephone: 100M WT-1010C2 – USER MANUAL – Rev.3.9 – Technical Support: Technical@witura.com COPYRIGHT ©2011 WITURA CORPORATION SDN BHD...
  • Page 43: Wt-1010C2 – User Manual – Rev.3.9 – Technical Support: Technical@Witura.com

    Terminal against defective parts and workmanship. Witura Corporation Sdn Bhd shall, at its option, repair or replace the defective equipment upon the return of such equipment to any Witura branch. This warranty applies ONLY to defects in components and workman-ship and NOT to damage due to causes beyond the...