Witura WT-1010C2 User Manual

Gsm alarm system
Hide thumbs Also See for WT-1010C2:

Advertisement

Quick Links

W
T
-
1
0
1
0
C
2
W
T
-
1
0
1
0
C
2
G
S
M
A
L
A
R
M
S
Y
S
T
E
M
G
S
M
A
L
A
R
M
S
Y
S
T
E
M
G
S
M
A
L
A
R
M
S
Y
S
T
E
M

User Manual

W
I
T
U
R
A
C
O
R
P
O
R
A
T
I
O
N
S
D
N
B
H
D
W
I
T
U
R
A
C
O
R
P
O
R
A
T
I
O
N
S
D
N
B
H
D
W
I
T
U
R
A
C
O
R
P
O
R
A
T
I
O
N
S
D
N
B
H
D

Advertisement

Table of Contents
loading

Summary of Contents for Witura WT-1010C2

  • Page 1: User Manual

    User Manual...
  • Page 2 POWER PORT Connect the provided Turn On or Off the Connect a 12V Power antenna to the Terminal Supply to the Terminal Terminal WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 3 (PIN9) Auxiliary +V Input 2 Output when (PIN10) PSTN Failed (PIN15) Input 3 (PIN11) Output 1 Output 2 Output 3 (PIN12) (PIN13) (PIN14) WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 4: Table Of Contents

    5.15 Setting the Delay Time of Transmitting the Alarm………………………………………………………40 5.16 Setting the Alarm Time for Audible Alarm……………………………………………………………………41 5.17 Miscellaneous Settings………………………………………………………………………………………………….41 6. Digital Communication Standard – Contact ID Protocol for WT-1010C2…………………………….44 7. Technical Specifications....................47 WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com...
  • Page 5: Introduction To Wt-1010C2 Gsm Alarm System

    WT-1010C2 USER MANUAL 1. Introduction to the WT-1010C2 GSM Alarm System The WT 1010C2 GSM Terminal is a wireless communicator for alarm and fire panels that uses the cell phone network (GSM) to transmit alarms and other panel event. The module checks the status of the PSTN line and in case the PSTN line becomes unavailable, the WT 1010C2 GSM emulate the line signal to the panel.
  • Page 6: Main Features Of The Wt-1010C2

    WT-1010C2 uses the telephone line as the main transmission line and uses the GSM voice channel as backup 4. The WT-1010C2 unit can continuously watches if a Contact ID is directed towards the security monitoring station through the wired or GSM network, and if either of the preset report codes is noticed, it sends an appropriate SMS message with definable text to a mobile phone numbers.
  • Page 7: Installation Instruction

    3.1) Description 1. Antenna: connect the antenna to the GSM module; place the antenna as far as possible from the WT-1010C2 and do not leave any coiling of the antenna cable to avoid radiant interference 2. SIM Card: disable the PIN code and set it to 1234 (default)
  • Page 8: Wt-1010C2 Inputs & Outputs Wiring Instructions

    SMS with a certain command. Note: When sending normal SMS with command below, the WT-1010C2 will turn On / Off the output relay and reply a message of output has turned On / Off to a programmable phone numbers.
  • Page 9: Installing The Sim Card

    SIM card lines up with the clipped corner of the SIM holder 3. Close the SIM door 4. Slide the SIM door to lock the SIM card in place 3.4) Power up the WT-1010C2 When power up the WT 1010C2, it will display as below LOADING:>>>>>...
  • Page 10 (try to keep it as far as possible from the WT-1010C2 unit antenna). Usually it is possible to find a suitable location for the phone with minimal level of interference.
  • Page 11: Wt-1010C2 Configuration Instructions (Via Voice)

    WT-1010C2 USER MANUAL 4. WT-1010C2 Configuration Instructions (Via Voice) 4.1 Introduction The WT-1010C2 can be programmed manually by a connected normal telephone. Connect to TEL1 Note: Before commencing programming it is advisable to read the below programming setting instructions thoroughly. To start with programming, user must...
  • Page 12 3) Programming the Administrator/Central Station Number Continue pressing *1* to start programming the administrator number 1 TEL: TEL: 13232353646 Enter administrator number and ended with # WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 13 Administrator numbers. To set the access control for administrator, you can press *11* to proceed. ANY – ON&OFF: WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 14 To setup time, you can press *16* to proceed. TIME: TIME: 08 : 30 : 00 Example: To set the time at 8.30am WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 15 The unit can send text alerts to 1 or all 8 of the programmed administrator’s mobile phone numbers. To do this setting, you can press *18* to proceed. SECT: WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 16 Each of them represents administrator 1 - 8 10) Setting the Account Number for Event Reporting When PSTN failure, AC failure or Auto Test, the WT-1010C2 will dial the programmable central station number and transmit the account number along with Contact-ID to the central station. To set the account number, you can press *36* to proceed.
  • Page 17 To set the auto test report time interval, you can press *17* to proceed. DSTM: DSTM: 12 : 00 : 00 Example: To set the auto test report time at 12.00pm WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 18 DTIMEM – ON&OFF: DTIMEM – ON&OFF: 1 To turn on this function simply press 1# To turn off this function simply press 0# WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 19 Example: Setting the unit to generate an Alert Message, call the administrators, generate a pulse (+V) and sound the audible alarm when PSTN failed. Simply input 1111# WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 20 Value: ON (1) or OFF (0) 18) Turn on the function of Inputs To turn on the function of input number 1, you can press *24* to proceed. WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 21 Example: To activate relay 1 to stay on for 50 seconds and with SMS reply from the unit after relay has turned off Simply input 000501# WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 22 In the event the administrator has not answered the call or engaged, it could take a while for the WT-1010C2 to call the next number. You can shorten the time for every call by programming the waiting time. Press *12* to proceed.
  • Page 23 The unit can be set to transmit a dialing number within a specific time. To set the delay time, you can press *34* to proceed. DTTRANSMIT: DTTRANSMIT: 00007 WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 24 To inquire all administrator numbers, you can press *32* to proceed. ADMIN: 1: 1234567890 All the administrator numbers will be displayed in sequence WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 25 To inquire the signal strength, you can press *20* to proceed. CSQ <23> The signal strength will be displayed on screen Press # to turn back WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 26: Wt-1010C2 Configuration Instructions (Via Sms)

    This happens because the WT-1010C2 recognizes any GSM number as administrator and answers to it. Warning: The administrator number must be program into the WT-1010C2 unit first via voice mode in order to use SMS programming mode.
  • Page 27: Time Setting

    LCD screen. 08:30:15 WT-1010 Return Message SETM-OK Note: Time setting is necessary for Auto Test Function at No. 9) “Auto Test” Settings (Page) WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 28: Turn Off The Feature Of Password Request When Accessing The System

    Note: You will need to enable the Password Login feature for the wireless listening function. 5.5 Setting the Account Number for Event Reporting When PSTN failure, AC failure or Auto Test, the WT-1010C2 will dial the programmable central station number and transmit the account number along with Contact-ID to the central station.
  • Page 29: Setting The Burst On And Burst Off Time Of Dtmf Tones

    Return Message ACCT:9999 Note: Please refer to page 43 for Contact-ID Protocol for WT-1010C2 5.6 Setting the Burst On and Burst Off time of DTMF tones The Burst ON and Burst OFF timing of the sending Contact-ID can be adjust by sending the following SMS command to the unit.
  • Page 30 PSTN unavailable. To turn On/Off this function, you can send the following SMS command to the unit. Text Command: *PSOF#X X stands for ON (1) or OFF (0) value WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 31: Ac Fail" Settings

    X stands for ON (1) or OFF (0) value When *ACCA#1 is applied, it will dial the administrator/central station number when AC failed. WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 32 When *ADAL#0 is applied, means audible alarm will not sound when AC failed. To turn on this function, you would send *ADAL#1 SMS command to the unit. WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 33: Auto Test" Settings

    It is possible to enable or disable this function by sending the following SMS command to the unit. Text Command: *DTM?#X X stands for ON (1) or OFF (0) value WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 34 SMS command to the unit. Text Command: *DTC?#X X stands for ON (1) or OFF (0) value WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 35: Input Settings

    The system has the function to send alert message to the user in the event of input triggered. It is possible to enable or disable this function by sending the following SMS command to the unit. Text Command: WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 36 Pulse), it will not send any alert message to administrator/central station number 1. To enable this function for input 1, you would send *INP1#1 SMS command to the unit. Return Message INP1-ON WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 37 When *ALM1#0 (Default) is applied, means audible alarm will not sound when Input 1 triggered. To turn on this function for input 1, you would send *ALM1#1 SMS command to the unit. Return Message ALM1-ON WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 38: Output Settings

    When *RLR1#1 (Default) is applied, means when Relay 1 has turned off, it will send a message to the programmable administrator number 1. WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 39: Setting The Waiting Time For Engaged Call

    In the event the administrator has not answered the call or engaged, it could take a while for the WT-1010C2 to call the next number. You can shorten the time for every call by sending the following SMS command to the unit.
  • Page 40: Setting For Adding Area Code When Transmitting The Alarm

    When *DATM#00007 is applied, the system will send out the dialing number to the programmable administrator/central station number within 7 seconds. Return Message WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 41: Setting The Alarm Time For Audible Alarm

    To inquire the status of the recipients that will receive alert messages, you can send the following SMS command to the unit. Text Command: *ASRE# WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 42 The system has the function of dialing the programmable administrator/central station numbers immediately when the below SMS command is issued. Text Command: *DIAL# WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 43 Permanent +V Output Facility 5.17.9 There is a permanent +V output when the WT-1010C2 is power on. This output is available on the connection PIN8 and ground on the main board. The output voltage is according to power supply used on WT-1010C2. It can be used to power on other facility or device.
  • Page 44: Digital Communication Standard - Contact Id Protocol For Wt-1010C2

    WT-1010C2 USER MANUAL 6. Digital Communication Standard - Contact ID Protocol for WT-1010C2 Objectives a) Provide information regarding events that are occurring on a customer’s premises. This information should be in a form that can easily be interpreted by a central station operator.
  • Page 45 Burst ON time - 50 msec. (50 min.,60 max.) Burst OFF time- 50 msec. (50 min.,60 max.) The details of the tones are contained in the following table. WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 46 750 msec. and a maximum period of 1 second. The transmitter must detect a minimum of 400 msec. of tone before considering the kissoff to be valid. WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 47: Technical Specifications

    Stability of frequency: better than 2.5PPM Signal sensitivity: -103dBM Transmit power: <2w Power: 220v±15% AC 10. Input Voltage Tolerances: 1~20VDC The max distance between terminal and telephone: 100M WT1010C2 – USER MANUAL – Rev.2.7 – Technical Support : Technical@witura.com COPYRIGHT ©2008 WITURA CORPORATION SDN BHD...
  • Page 48: Wt1010C2 – User Manual – Rev.2.7 – Technical Support : Technical@Witura.com

    Terminal against defective parts and workmanship. Witura Corporation Sdn Bhd shall, at its option, repair or replace the defective equipment upon the return of such equipment to any Witura branch. This warranty applies ONLY to defects in components and workman-ship and NOT to damage due to...

Table of Contents