Gsm intercom remote control and alarm system (21 pages)
Summary of Contents for Witura WT-1010SA
Page 1
WT‐1010SA Stand‐Alone GSM Alarm System User Manual and Installation Instructions Version: 1.2 Updated: 4 JAN 2012 WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 2
You can change the displayed text by sending a command by SMS to the unit. For examples, changing the zone 4 to “DOOR OPEN”. If the alarm zoning is not enough, the system is offering “lopping concept” It can lop up to 50 zoning. 2 remote control outputs: These heavy‐duty relay outputs can be turned on and off remotely through SMS. Remote control will be reachable by sending an SMS. For example SMS/Call in to switch on lighting, air conditioning system, generator, sensor or other equipment. Automatically call to 8 pre‐program phone numbers while alarming. The WT‐1010SA also will SMS to 8 programmable phone number to notify the user if any intruder. Open your auto gate with your basic telephone. Connect the WT‐1010SA with the auto gate and your house basic telephone. Besides you can use the WT‐1010SA as your house telephone, you also can open your auto gate by pressing a command at the basic telephone. WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Triggered”, “GSM Alive” if any of the above having problem. Auto test reporting system – after the owner program the reporting time, the WT‐1010SA will dial the programmable number to inform that “GSM Alive”. This is to make sure that in case of emergency, the GSM still functioning well. Standby rechargeable battery to prevent power failure or electricity cut off by intruder. The GSM will function as normal when no electricity supply. LCD display to check the GSM signal strength and battery capacity. INTERNAL VIEW LCD Display SIM Card Holder RF Receiver GSM Module Battery Backup Connector Main Switch Jumper DC Power Connector Phone Port Line Port 8 Digital Inputs 2 Relay Outputs Antenna Connector WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
WIRING DIAGRAM Installation Instructions: Note: It is essential that you read the step by step instructions fully prior to installing and programming the unit. Description: 1. Antenna: connect the antenna to the GSM module; place the antenna as far as possible from the WT‐ 1010SA and do not leave any coiling of the antenna cable to avoid radiant interference 2. SIM Card: disable the PIN code and set it to 1234 (default) For Transmitter Mode (Data or SMS): as with any transmitter, it requires an identifier, receiver telephone numbers, etc (refer to the complete information on Programming page) 3. Line Port: connect the line input to the PSTN or ISDN network. 4. Relay Outputs: connect to additional remote controlling outputs. 5. Phone Port: connect the phone port to any single line phone to make calls or programming. 6. Power Supply: connect to a 15VDC power supply 7. Operating State: Approximately 20s after power up check the operating state indicated by the Power LED: the LED is steady during power up phase, and then blinks when the connection to the GSM network is established. The Signal indicator LED will stay lit whenever there is signal. WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
WT‐1010SA Inputs & Outputs Wiring Instructions: R1 (OUT1) and R2 (OUT2) Remote Controlling Outputs These Relay outputs can be turned on or off remotely by SMS. When sending an SMS command for switching the relay, the WT‐1010SA will turn ON/OFF the output relay and sends a message to notify the administrator that the output has switched ON/OFF. L1 (ZONE 1), L2 (ZONE 2), L3 (ZONE 3), L4 (ZONE 4), L5 (ZONE 5), L6 (ZONE 6), L7 (ZONE 7) and L8 (ZONE 8) Connect L1, L2, L3, L4, L5, L6, L7 and L8 inputs to the sensors, when there is a short‐circuit impulse on the inputs the WT‐1010SA will send SMS or Call the administrator numbers. For Example: ZONE 1 is connected to a motion sensor, when there is an intrusion the WT‐1010SA will receive a short circuit impulse on ZONE 1 and automatically sends a signal to the monitoring station and also sends an SMS to notify the owner. Inputs and Outputs Wiring Diagram Installing the SIM Card: Note: Installing the SIM Card. Please be sure the initial 4 digits PIN code of the SIM card is disabled. This can be done by placing it in an unlocked mobile phone and first checking if the SIM requested any PIN code. If this is the case the PIN code can be disabled using the security settings on the phone. Warning! The WT‐1010SA identifies only 3V SIM Card. WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Proceed as follows: 1. Slide back the SIM holder and lift it up 2. Slide the SIM card into the SIM holder making sure that the clipped corner of the SIM card lines up with the clipped corner of the SIM holder 3. Close the SIM holder 4. Slide the SIM holder to lock the SIM card in place PROGRAMMING THE UNIT To program the unit you just need any fixed line telephone and connect it to the Phone port on the GSM unit. Any fixed line telephone for programming WT‐1010SA GSM Unit After the GSM module is connected to the GSM network, an attached fixed line phone can be used to make calls. If you pick up the phone, you will hear a dial tone. Simply dial the number you want to call (as if you are dialling from a normal fixed line phone). You can also dial the WT‐1010SA unit’s phone number from another phone, and its attached phone will ring as a normal landline phone would. If there is a busy tone on the attached telephone set, either the line you are calling is busy, or the GSM communicator is busy with previous communication at that moment (for example data transfer to the monitoring station). Note: Some telephone sets are sensitive to the GSM radio signal. For this reason you may hear a characteristic noise in the telephone receiver when calling. If the noise is disturbing, change the location of the phone set (try to keep it as far as possible from the WT‐1010SA unit antenna). Usually it is possible to find a suitable location for the phone with minimal level of interference. WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
The installer code is used to access program mode via handset. To program a new 8 digit installer code simply press in program mode. Enter the new installer code followed by # (eg. 87654321#) The display will show NEW PASSWORD: 87654321# To exit programming mode simply hang up the handset. NOTES: DO NOT LOSE THE INSTALLER CODE AS IT CANNOT BE RECOVERED IF LOST OR FORGOTTEN. YOU WILL NEED TO CONSULT WITH OUR TECHNICAL PERSONNEL FOR RESETTING THE SYSTEM TO DEFAULT STATE. Admin Phone Number 1 must be programmed to allow sending of SMS commands to the GSM Unit ATTENTION: PROGRAMMING METHODS – HANDSET AND SMS COMMANDS Please note that some options are programmed using a telephone handset connected to the GSM unit and other options are programmed by SMS message sent from a mobile phone. SMS COMMAND options are programmed by sending an SMS message from a mobile phone to the GSM Unit. The mobile phone used to send SMS Commands must be programmed as Admin Phone Number 1. WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 8
*6* *7* To program Admin Phone Number 2 to 8, repeat the sequence above using , *8* To DELETE a Phone Number enter # with no phone number. eg. To delete Admin Number 1. HANDSET In Program Mode *1*# Press To program the Admin Phone Number by SMS send: *TEL[N]#[phone number] SMS Command: N = Admin position 1 – 8 [phone number] = Admin phone numbers Example, to program phone number 0163934857 as “Admin 1” send: *TEL1#0163934857 TEL1=0163934857 The GSM unit will send this reply message: WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 9
Area Code / Phone Number Prefix To program prefix digits which will be automatically dialled before any phone number. HANDSET In Program Mode *24* Press Enter the prefix (max. 4 digits) followed by # (eg. 04#) AREA CODE: 04 OK Note: Once programmed, the Phone Number Prefix cannot be deleted it can only be replaced by a new prefix. *25* Use option to enable and disable dialling of the prefix. Enable / Disable Phone Number Prefix Use this option to enable the dialling of the Phone Number Prefix. HANDSET In Program Mode WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Dttransmit: 05 OK Program the Alert Recipients This option sets which of the 8 Admin Phone Numbers will receive SMS alerts. HANDSET In Program Mode *22* Press to select the option Enter either the digit 0 (No alert) or 1 (Send alert) for each of the 8 Admin Phone Numbers, followed by . 11111111# Example 1, to enable all Admin Numbers for alerts, press SECH: 11111111 OK 11100000# Example 2, to enable only Admin Numbers 1, 2 & 3 for alerts, press WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 11
Enquire the Setting of Alert Recipients Check the setting of alert recipients using a handset. HANDSET In Program Mode *47* Press The Alert Recipients will be displayed in sequence: SECH: 11110000 Setting the Calling Group of Administrator This setting will enable the system to call the certain group of administrator numbers when Input triggered or AC power failure. HANDSET In Program Mode *23* Press Enter the number 1 – 8 (Max. 1 digit) followed by # WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
*37* Press Enter the Waiting Time (Max. 2 digits in seconds) followed by # (e.g. 25#) 25# Example: to program the waiting time as 25 seconds, press Wait Time: 25 OK Note: The Waiting time range from 20 – 59 seconds (Default: 30 seconds) Program the PSTN Failure Options This function enables the possible alarm action for PSTN failure. HANDSET In Program Mode *45* Press to program the PSTN Failure alarm options PSTN Failure Options ME: Send SMS alert when PSTN failure AL: Activate the strobe light/siren when PSTN failure CA1: Call Admin number when PSTN failure CA2: Call Admin number when PSTN restored WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 13
PSTN Failure Message This option sets the SMS text which is sent when the PSTN line failure. *PSOF#[message] SMS Command: [message] = Up to 50 alphanumeric characters. Letters and numbers only, no special characters. Example: To program the system to send the SMS message “PSTN Failure”, send: *PSOF#PSTN Failure PSOF‐PSTN Failure The GSM unit will send this reply message: PSTN Restoral Message This option sets the SMS text which is sent when the PSTN line is restored. *PSON#[message] SMS Command: [message] = Up to 50 alphanumeric characters. Letters and numbers only, no special characters. Example: To program the system to send the SMS message “PSTN Restored”, send: *PSON#PSTN Restored PSON‐PSTN Restored The GSM unit will send this reply message: WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 14
Enter either the digit 0 (Disable) or 1 (Enable) for the 4 possible actions for the power failure alarm, followed by #. Example: To enable the system to send SMS alert and activate the strobe light when power failure, press 1100# ADC: ME:1 AL:1 CA1: 0 CA2: 0 OK Note: If the system calls you when the power failures simply answer the call and press # to acknowledge the alarm and the system will stop calling you. Enable/Disable the Alarm Inputs Function This option allows you to enable/disable the function of alarm inputs. HANDSET In Program Mode *16* Press to enable/disable the function of 8 alarm inputs To enable the function of all alarm inputs press 11111111# To disable the function of all alarm inputs press 00000000# WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 15
*30* Press to program Input 5 alarm options *31* Press to program Input 6 alarm options *32* Press to program Input 7 alarm options *33* Press to program Input 8 alarm options Input Options OP: Send SMS Alert when Input Triggered (Alarm Input to +12V) CL: Send SMS Alert when Input Restored (Remove +12V from Input) AL: Activate Strobe Light / Siren when Input Triggered CA1: Call Admin number when Input Triggered CA2: Call Admin number when Input Restored Enter either the digit 0 (Disable) or 1 (Enable) for the five possible actions for the input, followed by #. Example: To enable Input 1 to send SMS Alarm and Restoral messages and activate the strobe light when input *26*11100# is triggered, press IN1: OP:1 CL:1 AL:1 CA1: CA2: OK Follow the same procedure for input 2, 3, 4, 5, 6, 7 & 8. WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 16
Example: To program Input 1 to send the SMS message “ZONE 1 Open”, send: *USE1#ZONE 1 Open USE1‐ZONE 1 Open The GSM unit will send this reply message: Input Restoral Message This option sets the SMS text which is sent when an input is restored. *USC[N]#[message] SMS Command: [N] = Input number 1 ‐ 8. [message] = Up to 50 alphanumeric characters. Letters and numbers only, no special characters. Example: To program Input 1 to send the SMS message “ZONE 1 Closed”, send: *USC1#ZONE 1 Closed USC1‐ZONE 1 Closed The GSM unit will send this reply message: Program the Strobe Light / Siren Output Duration To program the strobe light / siren output duration on PIN24 and PIN25. The alarm time can be set between 00001 to 99999 seconds. Note that programming duration of 00000 seconds has no effect. HANDSET In Program Mode WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 17
Enable / Disable the Activation of Strobe Light / Siren Output when Input Triggered Use this option to enable or disable the activation of strobe light / siren output when the input triggered. *ALM[N]#X SMS Command: [N] = Input number 1 ‐ 8. X = 1 (Enable) or 0 (Disable) *ALM1#1 Example: To enable this function for input 1, send: ALM1‐ON The GSM unit will send this reply message: Arm / Disarm all the Alarm Inputs This option allows you to Arm / Disarm all the alarm inputs with handset. HANDSET In Program Mode *40* Press To arm all the alarm inputs press 1# To disarm all the alarm inputs press 0# WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 18
When it is disarmed, the system will reply a message: Host has been Disarm Set the Arm Delay Time This setting allows you to program the Arm Delay Time for alarm inputs. HANDSET In Program Mode *41* Press Enter the Arm Delay Time (Max. 2 digits in seconds) followed by # (e.g. 10#) 10# Example: to program the Arm Delay Time as 10 seconds, press ARM Delay Time 10 OK Note: The Arm Delay Time range from 20 – 59 seconds (Default: 00 seconds) WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 19
To program the internal time clock by SMS, send: *SETM#HH:MM:SS SMS Command: HH = Hour MM = Minutes SS = Seconds Example: To program the time to be 5:30PM, send: *SETM#17:30:00 Set Time OK The GSM unit will send this reply message: Set the Auto Test Report Options This setting allows you to choose the options of Auto Test Report. HANDSET In Program Mode *44* Press Auto Test Report Options Time Call?: Call the administrator phone number on the programmed time section Time Message?: Send SMS to the administrator on the programmed time section Enter either the digit 0 (Disable) or 1 (Enable) for the two possible actions for the report, followed by #. WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 20
*43* Press to program the time section 2 *42*120000# Example: To program the time section 1 as 12:00:00, press Alarm Time1 12:00:00 OK Auto Test Report Message This option sets the SMS text which is sent for Auto Test Report. *DSME#[message] SMS Command: [message] = Up to 50 alphanumeric characters. Letters and numbers only, no special characters. Example: To program the system to send the Auto Test text message “System Online”, send: *DSME#System Online DSME‐System Online The GSM unit will send this reply message: WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 21
Check the GSM signal strength by handset or SMS. HANDSET In Program Mode *46* Press The display will show the signal strength. 0 = Poor signal, 31 = Best signal, 99 = unknown or not detectable CSQ <28> OK To check GSM signal strength by SMS, send: *CSQ?# SMS Command: CSQ=<28> The GSM unit will reply for example: WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Remote Control Outputs by SMS This allows you to turn outputs on by SMS. This can be used to switch on lights or open the gate with a relay. Note: The mobile phone used to send SMS commands must be programmed as Admin Phone Number. *RLY[N]#[time] SMS Command: N = Output number 1 or 2 [time] = relay on time in seconds between 00000 and 99999 seconds. To toggle outputs, send the text ON or OFF instead of a time value. See the example below. Example 1: To program Output 1 to stay on for 20 seconds, send: *RLY1#00020 RLY1‐00020 The GSM unit will reply: Example 2: To program Output 1 to stay on indefinitely, send: *RLY1#ON RLY1‐ON The GSM unit will reply: WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 23
RE: 1 The options for RE: are 0 = Do not send SMS reply when the output turns off. 1 = Send SMS reply when the output turns off. Setting the SMS Reply for Output Relay Off This setting allows you to enable/disable the SMS reply when the output turns off by SMS. *RER[N]#X SMS Command: N = Output number 1 or 2 X = 1 (Enable) or 0 (Disable) *RER1#1 Example: To enable the SMS reply function for output relay 1, send: RER1‐ON The GSM unit will send this reply message: Adjusting the Microphone and Speaker Volume This setting allows you to adjust the Microphone and Speaker volume of the WT‐1010SA unit by handset. HANDSET In Program Mode WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 24
HANDSET In Program Mode *12* Press Enter twice the 4 digits PIN code followed by # (e.g. 1234#) PIN: 1234 OK Clear the PIN Code of the WT‐1010SA Device Clear the programmed PIN code. HANDSET In Program Mode *14* Press Enter either the digit 0 (Cancel) or 1 (Confirm) Clear PIN? 1 OK WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 25
Enable SIM PIN Protection This setting allows you enable SIM PIN protection. HANDSET In Program Mode *18* Press Enter the 4 digits PIN code followed by # (e.g. 1234#) PIN Protected ON PIN: 1234 OK Disable SIM PIN Protection This setting allows you disable SIM PIN protection. HANDSET In Program Mode *19* Press Enter the 4 digits PIN code followed by # (e.g. 1234#) WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
HANDSET In Program Mode *17* Press Press any button on the remote control to learn RF Learn OK Note: You are allowed to add up to 5 remote controls to operate the system. Disarm Arm Activate Alarm Siren Activate Relay 1 Reset the WT‐1010SA Unit This setting allows you reset the WT‐1010SA Unit. HANDSET In Program Mode *21* Press WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...
Page 27
Enter either the digit 0 (Cancel) or 1 (Confirm) Reset The Machine? 1 OK WITURA CORPORATION SDN BHD | Stand‐Alone GSM Alarm System Instruction Manual ...