VERSION: 1.2 UPDATED: AUG 2013 WT‐1672A GSM Power Outage Alarm USER MANUAL WITURA TECHNOLOGY SDN BHD | WT‐1672A GSM Power Outage Alarm User Manual V1.8 ...
Page 2
The GSM Remote Control system supports timer function, the user can set schedule to turn on / off the switch. For example, put your pump, motor on a schedule. “Turn off in 5 minutes”, “turn on at 17:00, “turn on 1 year later” This function is important to use in the renting and leasing industry of electrical appliances, heavy vehicle, and rental of site equipment to turn off the machines when off hire time completed This function also important as the reminder to the owner to monitor the SIM Card expiry date. User can instruct the unit to trigger the relay in the specified times and sent the SMS to the user to keep the SIM card active when expiry dates. Typical uses include: • waking you in the event of a power cut; • fridge monitoring & freezer monitoring; • fish tank monitoring & aquarium monitoring; • generator monitoring; • sump pump monitoring; • computer equipment monitoring; • heating system monitoring; • chemical storage monitoring; • and other applications. WITURA TECHNOLOGY SDN BHD | WT‐1672A GSM Power Outage Alarm User Manual V1.8 ...
Page 3
Both Calls used to Latch the Relay either on or off are automatically disconnected, once the relays are activated and never incur any Network Call Costs. Beside calls to switch off or on, the unit also can be permanently switch off and on by sending the unit a text message command WITURA TECHNOLOGY SDN BHD | WT‐1672A GSM Power Outage Alarm User Manual V1.8 ...
Page 4
Step 1 ‐ The simplest set up methods to set up Administrator number Applied the “KISS Principle”, keep it simple, stupid. The GSM Power Outage Alarm is easy to setup and use. Insert the SIM card, simply use your mobile phone call to the unit, your mobile phone number will automatically register as the 1st Administrators You will receive the following SMS message from the unit – Administrator: 1: 18617185299 (your phone number) 2: 3: 4: 5: You already finish the set up. Now, you can use your mobile phone call to the SIM Card number switch the device on permanently. Another call to the SIM Card will switch the device off permanently. If you do not required to go through details setting, please process to STEP3 – Final Installation and Wiring. WITURA TECHNOLOGY SDN BHD | WT‐1672A GSM Power Outage Alarm User Manual V1.8 ...
Page 5
This means you already reset the unit to factory default. Now you can start to call again to set the administrator. This method of setting is only allowed to set 1 administrator number. If you wish to set more administrators, please go to Step 3 – Installation and set up If you required to change the administrator number in the future, simply sent the SMS *1672* to the unit. You will receive the SMS message “Factory Reset OK!” WITURA TECHNOLOGY SDN BHD | WT‐1672A GSM Power Outage Alarm User Manual V1.8 ...
Page 6
4 Check phone number you *2* Administrator: program in the list 1: 15989427391 2: 18617185300 3: 4: 5: 2013‐10‐10 16:08 Thu 5 Delete the admin number in the list. *3*N# Administrator: Delete Admin Number 1: 15989427391 Delete 1st admin *3*1# Delete 2nd admin *3*2# N = Admin number 1‐ 5 2: For example, if you want to 3: Delete 3rd admin *3*3# delete admin no 2. 4: Delete 4th admin *3*4# just enter *3*2# 5: Delete 5th admin *3*5# 2013‐10‐10 16:08 Thu WITURA TECHNOLOGY SDN BHD | WT‐1672A GSM Power Outage Alarm User Manual V1.8 ...
Page 7
When Activate Alarm Function, is equal to using the Remote Control to arm. The D7 Green LED light in the system will turn on. All the function such as Outage Alarm, Temperature Report. 9 Checking the status of the Alarm *11* Alarm switch<ON> Check the status of the alarm Function in the system function in the system 2013‐10‐10 16:29 Thu WITURA TECHNOLOGY SDN BHD | WT‐1672A GSM Power Outage Alarm User Manual V1.8 ...
Page 8
Master relay on time: Checking the schedule time for Master Relay ON/OFF Master relay off time: Master Relay ON/OFF, when the 2013‐10‐10 16:33 time reach, the system will operate and it will delete the 2013‐10‐10 16:35 Thu schedule time automatically. 13 Delete the schedule time for the *15*N# Master relay on time: N=0 (Delete schedule of Relay Master Relay ON/OFF Master relay off time: OFF Time) N=1 (Delete schedule of Relay 2013‐10‐14 11:08 Mon ON Time) WITURA TECHNOLOGY SDN BHD | WT‐1672A GSM Power Outage Alarm User Manual V1.8 ...
Page 9
Anybody can call to the unit to When Setting as Open control the system. Please take Mode *23*0# note that the Privacy and Mode switch <OFF> Security before you decide to use the Open Mode 2013‐10‐10 17:13 Thu Factory Default is N=1 for Security Mode WITURA TECHNOLOGY SDN BHD | WT‐1672A GSM Power Outage Alarm User Manual V1.8 ...
Page 10
Alarm administrative number 2 = when the AC power down the units will call the administrative number WITURA TECHNOLOGY SDN BHD | WT‐1672A GSM Power Outage Alarm User Manual V1.8 ...
Page 11
Connect the cable to terminals 110V ‐ 220V & N ensuring positive is connected to terminal 110v ‐ 200V, switch on the power supply , the red power LED will light indicating power is present, the blue network LED indicator will initially flash quickly, once logged onto the network , it will flash more slowly approximately one every 3 ‐4 seconds It is recommended that the GSM Remote Control Switch be programmed to operate as required before final installation. WITURA TECHNOLOGY SDN BHD | WT‐1672A GSM Power Outage Alarm User Manual V1.8 ...
Page 12
5 6 Board Label J3 Power Supply Description Relay Power Supply 1 Connection NC No COM E N L Details Note 1. The Relay (J3 ) Was using for turning on and off the electrical appliance only 2. User can set up the Relay by own requirement 3. If using to monitoring the Power outage only, doesn’t required to connect Wire with Relay Example Connection with Freezer WITURA TECHNOLOGY SDN BHD | WT‐1672A GSM Power Outage Alarm User Manual V1.8 ...
4. I am not receiving any text messages when once every 3 seconds (see 2 above). Ensure the SIM initially programming the unit card has credit Most but not all PAY SIM cards will be de‐activated by the network if not used to make an outgoing voice call 5. The unit has been working for several months or send an SMS text message within a specific period. and has now stopped responding to calls and To prevent this simply send a txt command *0*PW#, text commands then *2*, it will reply by text message, do this once a month to keep the SIM card active WITURA TECHNOLOGY SDN BHD | WT‐1672A GSM Power Outage Alarm User Manual V1.8 ...
Warranty Witura Technology Sdn Bhd warrantees the WT‐1672A GSM Temperature Alert and Monitoring System against defective parts and workmanship. Witura Technology Sdn Bhd shall, at its option, repair or replace the defective equipment upon the return of such equipment to any Witura branch. This warranty applies ONLY to defects in components and workman‐ship and NOT to damage due to causes beyond the control of Witura, such as incorrect voltage, lightning damage, mechanical shock, water damage, fire damage, or damage arising out of abuse and improper application of the equipment. Note: Wherever possible, return only the PCB to Witura Service Centres. DO NOT return the enclosure. The WT‐1672A is a product of Witura Technology Sdn Bhd And is manufactured by Shenzhen Witura Telecommunications Co., Ltd. WARNING For safety reasons, only connect equipment with a telecommunications compliance label. This includes customer equipment previously labelled permitted or certified. WITURA TECHNOLOGY SDN BHD | WT‐1672A GSM Power Outage Alarm User Manual V1.8 ...