  • Page 1   VERSION: 1.2   UPDATED: AUG 2013          WT‐1672A  GSM Power Outage Alarm      USER MANUAL                        WITURA TECHNOLOGY SDN BHD |                         WT‐1672A GSM Power Outage Alarm User Manual V1.8 ...
  • Page 2 The  GSM  Remote  Control  system  supports  timer  function,  the  user  can  set  schedule  to  turn  on  /  off  the  switch. For example, put your pump, motor on a schedule. “Turn off in 5 minutes”, “turn on at 17:00, “turn  on 1 year later”    This function is important to use in the renting and leasing industry of electrical appliances, heavy vehicle,  and rental of site equipment to turn off the machines when off hire time completed       This function also important as the reminder to the owner to monitor the SIM Card expiry date. User can  instruct the unit to trigger the relay in the specified times and sent the SMS to the user to keep the SIM card  active when expiry dates.     Typical uses include:  •  waking you in the event of a power cut;  •  fridge monitoring & freezer monitoring;  •  fish tank monitoring & aquarium monitoring;  •  generator monitoring;  •  sump pump monitoring;  •  computer equipment monitoring;  •  heating system monitoring;  •  chemical storage monitoring;  •  and other applications.              WITURA TECHNOLOGY SDN BHD |                         WT‐1672A GSM Power Outage Alarm User Manual V1.8   ...
  • Page 3 Both  Calls  used  to  Latch  the  Relay  either  on  or  off  are  automatically  disconnected,  once  the  relays  are  activated and never incur any Network Call Costs.    Beside calls to switch off or on, the unit also can be permanently switch off and on by sending the unit a text  message command                                              WITURA TECHNOLOGY SDN BHD |                         WT‐1672A GSM Power Outage Alarm User Manual V1.8   ...
  • Page 4 Step 1 ‐ The simplest set up methods to set up Administrator number           Applied the “KISS Principle”, keep it simple, stupid.  The GSM Power Outage Alarm is easy to setup and use. Insert the SIM card, simply use your mobile phone  call to the unit, your mobile phone number will automatically register as the 1st Administrators    You will receive the following SMS message from the unit –     Administrator:              1: 18617185299 (your phone number)               2:               3:              4:              5:         You already finish the set up.  Now, you can use your mobile phone call to the SIM Card number switch the  device on permanently. Another call to the SIM Card will switch the device off permanently.       If you do not required to go through details setting, please process to STEP3 – Final Installation and Wiring.     WITURA TECHNOLOGY SDN BHD |                         WT‐1672A GSM Power Outage Alarm User Manual V1.8   ...
  • Page 5 This  means  you  already  reset  the  unit  to  factory  default.  Now  you  can  start  to  call  again  to  set  the  administrator.      This method of setting is only allowed to set 1 administrator number. If you wish to set more administrators,  please go to Step 3 – Installation and set up      If you required to change the administrator number in the future, simply sent the SMS *1672* to the unit.  You will receive the SMS message “Factory Reset OK!”                                  WITURA TECHNOLOGY SDN BHD |                         WT‐1672A GSM Power Outage Alarm User Manual V1.8   ...
  • Page 6 4  Check phone number you  *2*   Administrator:     program in the list   1: 15989427391  2: 18617185300  3:  4:  5:    2013‐10‐10 16:08 Thu  5  Delete the admin number in the list.    *3*N#  Administrator: Delete Admin Number     1: 15989427391  Delete 1st admin  *3*1#   Delete 2nd admin *3*2#   N = Admin number 1‐ 5    2:   For example, if you want to  3:  Delete 3rd admin *3*3#  delete admin no 2.  4:  Delete 4th admin *3*4#  just enter *3*2#  5:  Delete 5th admin *3*5#    2013‐10‐10 16:08 Thu  WITURA TECHNOLOGY SDN BHD |                         WT‐1672A GSM Power Outage Alarm User Manual V1.8   ...
  • Page 7 When  Activate  Alarm  Function,  is  equal  to  using  the  Remote  Control  to  arm.  The  D7  Green  LED light in the  system will turn  on.  All  the  function  such  as  Outage  Alarm,  Temperature  Report.  9  Checking the status of the Alarm  *11*  Alarm switch<ON> Check the status of the alarm  Function in the system    function in the system    2013‐10‐10 16:29 Thu  WITURA TECHNOLOGY SDN BHD |                         WT‐1672A GSM Power Outage Alarm User Manual V1.8   ...
  • Page 8 Master relay on time:   Checking  the  schedule  time  for  Master Relay ON/OFF  Master relay off time:  Master Relay ON/OFF, when the  2013‐10‐10 16:33  time  reach,  the  system  will    operate  and  it  will  delete  the  2013‐10‐10 16:35 Thu  schedule time automatically.  13  Delete the schedule time for the  *15*N#  Master relay on time:   N=0 (Delete schedule of Relay  Master Relay ON/OFF  Master relay off time:   OFF Time)    N=1 (Delete schedule of Relay  2013‐10‐14 11:08 Mon  ON Time)  WITURA TECHNOLOGY SDN BHD |                         WT‐1672A GSM Power Outage Alarm User Manual V1.8   ...
  • Page 9 Anybody  can  call  to  the  unit  to  When Setting as Open  control  the  system.  Please  take  Mode *23*0#  note  that  the  Privacy  and  Mode  switch <OFF>  Security  before  you  decide  to    use  the  Open  Mode 2013‐10‐10 17:13 Thu    Factory  Default  is  N=1  for  Security Mode  WITURA TECHNOLOGY SDN BHD |                         WT‐1672A GSM Power Outage Alarm User Manual V1.8   ...
  • Page 10 Alarm  administrative number   2  =  when  the  AC  power  down  the  units  will  call  the  administrative number                                   WITURA TECHNOLOGY SDN BHD |                         WT‐1672A GSM Power Outage Alarm User Manual V1.8   ...
  • Page 11 Connect  the  cable  to  terminals  110V  ‐  220V  &  N  ensuring  positive  is  connected  to  terminal  110v  ‐  200V,  switch on the power supply , the red power LED will light indicating power is present, the blue network LED  indicator will initially flash quickly, once logged onto the network , it will flash more slowly approximately  one every 3 ‐4 seconds   It is recommended that the GSM Remote Control Switch be programmed to operate as required before final  installation.                          WITURA TECHNOLOGY SDN BHD |                         WT‐1672A GSM Power Outage Alarm User Manual V1.8   ...
  • Page 12 5  6  Board Label  J3  Power Supply  Description  Relay  Power Supply 1  Connection  NC  No  COM  E  N  L  Details      Note   1.  The Relay (J3 ) Was using for turning on and off the electrical appliance only   2.  User can set up the Relay by own requirement   3.  If using to monitoring the Power outage only, doesn’t required to connect Wire with Relay      Example Connection with Freezer                   WITURA TECHNOLOGY SDN BHD |                         WT‐1672A GSM Power Outage Alarm User Manual V1.8   ...
  • Page 13: Troubleshooting

    4. I am not receiving any text messages when  once  every  3  seconds  (see  2  above).  Ensure  the  SIM  initially programming the unit  card has credit  Most but not all PAY SIM cards will be de‐activated by  the network if not used to make an outgoing voice call  5. The unit has been working for several months  or send an SMS text message within a specific period.  and has now stopped responding to calls and  To  prevent  this  simply  send  a  txt  command  *0*PW#,  text commands  then *2*, it will reply by text message, do this once a  month to keep the SIM card active  WITURA TECHNOLOGY SDN BHD |                         WT‐1672A GSM Power Outage Alarm User Manual V1.8   ...
  • Page 14: Warranty

      Warranty    Witura Technology Sdn Bhd warrantees the WT‐1672A GSM Temperature Alert and Monitoring System  against defective parts and workmanship. Witura Technology Sdn Bhd shall, at its option, repair or  replace the defective equipment upon the return of such equipment to any Witura branch. This  warranty applies ONLY to defects in components and workman‐ship and NOT to damage due to causes  beyond the control of Witura, such as incorrect voltage, lightning damage, mechanical shock, water  damage, fire damage, or damage arising out of abuse and improper application of the equipment.    Note: Wherever possible, return only the PCB to Witura Service Centres.  DO NOT return the enclosure.      The WT‐1672A is a product of  Witura Technology Sdn Bhd  And is manufactured by  Shenzhen Witura Telecommunications Co., Ltd.        WARNING  For safety reasons, only connect equipment with a telecommunications compliance label. This    includes customer equipment previously labelled permitted or certified. WITURA TECHNOLOGY SDN BHD |                         WT‐1672A GSM Power Outage Alarm User Manual V1.8   ...