Turn the outer filter pan upside down and
slightly elevate the end to allow all water to
drain from the suction tube.
If you notice that the system is pumping
slowly or not at all, verify that the filter pan
screen is on the bottom of the filter pan, with
the paper on top of the screen. If the filter
screen and paper are correctly installed,
change the filter paper and verify that the
o-ring on the bottom of the filter pan is present
and in good condition. NOTE: With fresh
paper and properly installed o-rings, the
system should refill the fryer in 2 to 3 minutes.
Immediately after each use, drain the Power
Shower completely. If you suspect blockage,
45 SERIES GAS FRYERS
CHAPTER 5: PREVENTIVE MAINTENANCE
unscrew the clean-out plugs at each corner of
the frame. Place the frame in a pan of hot
water for several minutes to melt any
accumulation of solidified oil/shortening. Use
a long, narrow bottlebrush with hot water and
detergent to clean inside the tubes.
necessary, insert a straightened paper clip or
similar instrument into the holes in the frame
to remove any blockages.
thoroughly, and reinstall the plugs before
using.
Failure to reinstall the clean-out plugs
will cause hot oil to spray out of the
frypot during the filtering process,
creating a burn hazard to personnel.
5-6
Rinse, dry
DANGER