Heater Data - Trane 4WCY4024 Product Data

Single packaged convertible heat pump 14 seer 2-5 ton r-410a
Hide thumbs Also See for 4WCY4024:
Table of Contents

Advertisement

ELECTRIC
UNIT MODEL
HEATER MODEL
^W/TC*3018-060
1
BAYHTRV105E
^W/TCY4024-060
1
^WCZ6036-060
1
^W/TC*3018-060
1
^W/TCY4024-060
1
BAYHTRV108E
^WCZ6036-060
1
^W/TC*3024-060
1
BAYHTRV110E
^W/TCY4024-060
1
^WCZ6036-060
1
^W/TC*3030-060
1
BAYHTRV115E#
^W/TCY4030-060
1
^WCZ6036-060
1
^W/TC*3042-060
1
BAYHTRV120E#
^W/TCY4042-060
1
^WCZ6048-060
1
4WC*3042
1
^W/TC*3060
1
BAYHTRV125E#
^W/TCY4042-060
1
^WCZ6048-060
1
^W/TC*3036-060
3
BAYHTRV305E
^W/TCY4036-060
3
^WCZ6036-060
3
^W/TC*3036-060‡3
^W/TCY4036-060‡3
BAYHTRV308E
^WCZ6036-060‡3
^W/TC*3036-060‡3
BAYHTRV310E
^W/TCY4036-060‡3
^WCZ6036-060‡3
^W/TC*3036-060‡3
BAYHTRV315E
^W/TCY4036-060‡3
^WCZ6036-060‡3
^W/TC*3048-060‡3
BAYHTRV320E
^W/TCY4048-060‡3
^WCZ6048-060‡3
^W/TC*3060‡3
^W/TCY4048-060‡3
BAYHTRV325E#
^WCZ6048-060‡3
^W/TC*3036-060‡4
BAYHTRV405E
^WCZ6036-060‡4
^W/TC*3036-060‡4
BAYHTRV408E
^WCZ6036-060‡4
^W/TC*3036-060‡4
BAYHTRV410E
^WCZ6036-060‡4
^W/TC*3036-060‡4
BAYHTRV415E
^WCZ6036-060‡4
^W/TC*3048-060‡4
BAYHTRV420E
^WCZ6048-060‡4
^W/TC*3060‡4
BAYHTRV425E
^WCZ6048-060‡4
NOTES:
1. Any power supply and circuits must be wired and protected in accordance with local electrical codes.
2. The MCA values listed are for electric heater only.
3. Field wire must be rated at least 75°C
4. The HACR circuit breaker is for U.S.A. installations only.
5. For Canada installation reference only.
# Heater uses fuses.
‡ = A or B

Heater Data

Table 1. 4WCY4024 to 4WCY4060 Heater Data
HEATER CAPACITY
RATED
PHASE
AMPS
VOLTAGE
KW
208/240
1
18/21
3.76/5.0
208/240
1
29/33
6.0/8.0
208/240
1
36/42
7.5/10.0
208/240
1
54/63
11.27/15.0 38500/51200
208/240
1
72/83
15.0/20.0
208/240
1
90/104 18.78/25.0
3
10/12
3.76/5.0
208/240
208/240
3
17/19
6.0/8.0
208/240
3
21/24
7.5/10.0
208/240
3
31/36
11.27/15.0
208/240
3
42/48
15.0/20.0
208/240
3
52/60
18.78/25.0 64100/85300
480
3
6
5.0
480
3
10
8.0
480
3
12
10.0
480
3
18
15.0
480
3
24
20.0
480
3
30
25.0
KW/STAGE
NO. OF
STAGES
BTUH
1
12800/17100
1
3.76/5.0
20500/27300
1
6.0/8.0
25600/34100
1
7.5/10.0
2
7.5/10.0
51200/68300
2
7.5/10.0
64100/85300
2
11.26/15.0 7.5/10.0
12800/17100
1
3.76/5.0
20500/27300
1
6.0/8.0
25600/34100
1
7.5/10.0
38500/51200
2
7.5/10.0
51200/68300
2
7.5/10.0
2
11.26/15.0 7.5/10.0
17100
1
5.0
27300
1
8.0
34100
1
10.0
51200
2
10.0
68300
2
10.0
85300
2
1
5
0 .
8
MAX FUSE OR
CANADA ONLY
MCA
HACR CKT
MAX. CKT BKR
BKR SIZE (4)
2
23/26
25/30
36/41
40/45
45/52
45/60
3.76/5.0
68/78
70/80
7.5/10.0 90/104
90/110
113/130
125/150
13/15
15/15
21/24
25/25
26/30
30/30
3.76/5.0
39/45
40/45
7.5/10.0
52/60
60/60
65/75
7
0
8 /
0
8
15
13
15
15
15
5.0
23
25
10.0
30
30
10.0
38
40
SIZE (5)
25/30
40/45
45/60
70/80
90/110
125/150
15/15
25/25
30/30
40/45
60/60
70/80
15
15
15
25
30
4
0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents