Start Mode
Fram e Start Trigger Mod e
Fram e Start Trigger Activation
Fram e Start Delay
GigE Vision Input Controls
The Line Trigger Control section d escribes all featu res related to line acqu isition u sing trigger(s). One
or m any Trigger(s) can be u sed to control the start of an Acqu isition, of a Line. It can also be u sed to
control the exp osu re d u ration at the beginning of a line .
Parameter
Line Trigger Mod e
Line Trigger Sou rce
Line Trigger Activation
External Line Trigger Frequ ency
Read External Line Frequ ency

Input / Output Control

CamExpert groups the camera I / O Controls Parameters in either the Inputs group or the Outputs. These parameters
allow configuring the Spyder3 inputs and outputs for type of signal and signal polarity.
GigE Vision Input Controls
This group contains the features that allow the configuration of the camera physical input lines (pins)
Parameter
Line Selector
Teledyne DALSA
Sp ecifies w hether the external fixed length fram e trigger is
on or off. If the Fram eTriggerActiveMod e is on then it takes
p reced ence.To tu rn On, p lease DeviceScanTyp e to Linescan
(Start Mod e).
Sp ecifies w hat typ e of signal(i.e. high, or low ) cau ses a
fixed length fram e trigger w hen Fram e Start Trigger Mod e
is On.
Enable the d elayer.
Line Trigger Function Group
The state of the line trigger. If the trigger is off, then the line
trigger is internally generated otherw ise it is cau sed by an
external signal
The external line that cau ses a line trigger.The line trigger is
from GPIO_PIN 0. This featu re is available only w hen Line
Trigger Mod e in set to On.
Sp ecifies w hat typ e of signal(i.e. high, or low ) cau ses a line
trigger if Line Trigger Mod e is On.
Read s the external line trigger frequ ency. N OTE: The
cam era cannot d etect frequ ency less than 5 H z and w ill
d isp lay 1 if it cannot d etect a signal. This featu er is
available w hen the Line Trigger Mod e is se to ON and
Sensor Direction Control is set to External
Read the external line trigger frequ ency and u p d ates the
ExternalLineTriggerFrequ ency register. This featu re is
available w hen the Line Trigger Mod e is set to On.
Inputs Group
This feature selects which physical line (or pin) of the external
device connector to configure. When a Line is selected, all the
other Line features will be applied to its associated I/O control
block and will condition the resulting input or output signal.
Line0-- Line Trigger, Line1-- Frame Trigger, Line2 -- Direction.