Cutting The Vent Tubes - HouseWarmer HWDV080DVN-2 Installation Instructions And Owner's Manual

Direct vent wall furnace
Table of Contents

Advertisement

With the furnace installed on wall the 5" (127 mm) diameter air inlet tube and 3" (76 mm) diameter flue outlet tube are to be marked 
and cut using the following procedure. After cutting the tubes, each tube should be individually checked for proper length before
installing by fitting in place.
3
4
5
Page 22

cuttinG tHe Vent tuBeS

MARKER
FLUE OUTLET TUBE
COLLAR OF
FLUE OUTLET
Attach 5" (127 mm) diameter air inlet tube onto the collar of air drop
assembly. Be sure 5" (127 mm) diameter air inlet tube is placed as
far as possible onto the collar of the air drop assembly. Mark the
5" (127 mm) diameter air inlet tube 1 7/16" (36.5 mm) beyond the
mounting surface for the outside wall plate. Remove 5" (127 mm)
diameter air inlet tube from collar of air drop assembly.
Attach 3" (76 mm) diameter flue outlet tube onto flue outlet collar 
on combustion chamber. Be sure 3" (76 mm) diameter flue outlet 
tube  is  placed  as  far  as  possible  onto  the  collar  of  flue  outlet. 
Mark the 3" (76 mm) diameter flue outlet tube 2 7/8" (73.0 mm) 
beyond the mounting surface for the outside wall plate. Remove
3" (76 mm) diameter flue outlet tube from collar of flue outlet on 
combustion chamber.
Mark or wrap tape completely around the tubes at the marked points
to help in making a true cut. Do not crimp or enlarge tubes.
27536-0-0610