Read this manual thoroughly to operate the Network function. First, read the user's manual of the projector to understand the basic operation of the projector and the safety instructions. The safety instructions in the manuals should be followed strictly. User Manual for LX505/LX605...
Model Numbers : LX505, LX605 Trade Name : Christie Responsible party : CHRISTIE DIGITAL SYSTEMS, Inc. Address : 10550 Camden Drive Cypress, CA 90630 U.S.A. LX505/LX605 Network User Manual 020-00023 -01 Rev.1 ( 2-20 0)
CAUTION IN USING NETWORK FUNCTION assumes no responsibility for the loss or damage CHRISTIE DIGITAL SYSTEMS, Inc. of data, or damage of the computer caused by using this projector. Making back-up copies of valuable data in your computer is recommended. LX505/LX605 Network User Manual...
Chapter 1 Preparation Describes features and operating environment of this projector. LX505/LX605 Network User Manual LX505/LX605 Network User Manual 020-00023 -01 Rev.1 (12-2009)
SNMP manag- Trap ing software. Refer to the owner's manual of the "PJ You received a Trap. Net work Manager" sup - Trap SNMP Manager plied separately for further details. LX505/LX605 Network User Manual...
If you do not use the func- tion E-mail Alert, this application is not required. Network specifications of the projector LAN Terminal Data communication standards 100Base-TX (100Mbps)/10Base-T (10Mbps) Protocol TCP/IP LX505/LX605 Network User Manual...
Page 10
Other product or brand names in this manual are registered trademarks or trademarks of their respective owners. * Unauthorized use of a part or whole of the contents in this manual is prohibited. * The contents of this manual are subject to change without notice. LX505/LX605 Network User Manual...
So it is not required to install the software into your computer. For PJ Network Manager function, it is required to install the software. Please see the own- er's manual of "PJ Network Manager Function". LX505/LX605 Network User Manual...
Chapter 2 Setup Procedures Describes how to configure the network. LX505/LX605 Network User Manual LX505/LX605 Network User Manual 020-00023 -01 Rev.1 (12-2009)
“Please wait...” message will appear, and switching operation will start. Switching will take a while and the projector’s LINK/ACT Lamp will be on or blink, and after completing the operation, the “Please wait...” message will disappear. LX505/LX605 Network User Manual...
Page 15
*1 Set "On" only when the DHCP server is available on your network environment. *2 Set [255.255.255.255] if the network does not provide the gateway (router). *3 Set [255.255.255.255] if you do not use the function E-mail alert. LX505/LX605 Network User Manual...
Select "Network information" in the Network menu and press Point or SELECT button to show LAN setting environment of the currently selected projector. (The description below is an example and different from what will be shown.) * The numerical value is a setting example. LX505/LX605 Network User Manual...
4. All the wired LAN settings will go back to the factory default settings. For details, refer to “Wired LAN factory default settings” as shown in the table below. Wired LAN factory default settings Parameter Settings DHCP IP ADDRESS 169.254.100.100 SUBNET MASK 255.255.0.0 GATEWAY ADDRESS 255.255.255.255 DNS ADDRESS 255.255.255.255 LX505/LX605 Network User Manual...
Describes basic operations and settings for controlling the projec- tor by using the web browser. It is required that computer and projector is connected to the network and the network address is properly configured. LX505/LX605 Network User Manual LX505/LX605 Network User Manual 020-000232-01 Rev.1 (12-2009)
* The entering User Name must be "user" and it can not be changed. [Note] When accessing the projector for the first time or the Network PIN code "0000" is set, the auto-login will be performed and the next main setting page is displayed. LX505/LX605 Network User Manual...
Main setting page in the display Sub menu tab Switches the sub menu tab. Setting page Main menu Displays the control and For selection of control and setting items according to setting items of the projector. the selected menu. LX505/LX605 Network User Manual...
Each item has a valid setting range. The setting value exceeding this becomes invalid. Some con- trol items can not be used depending on the selecting input mode or functions of the projector you use. In this case, the values of those items are indicated with "---". LX505/LX605 Network User Manual...
Page 23
How to use the setting page Radio button setting Select an item by selecting a radio button. Check box setting Select items by ticking on check boxes. LX505/LX605 Network User Manual...
Language ....Switches display language on the setting page. English or Japanese. Model name ..Indicates the model name of the projector SERIAL NO...Indicates the serial number of the projector Network PIN code ..Sets the Network PIN code to login the setting page ( p.23) LX505/LX605 Network User Manual...
The default Network PIN code [0000] means no Network PIN code is set. When you connect the projector to the network, it is recommended to set a new Network PIN code. Only a four-digit number is valid for the Network PIN code. LX505/LX605 Network User Manual...
* If you make incorrect settings, you cannot find out the new network settings. Be careful to set up them correctly, otherwise you cannot connect to the projector. It is recommended to make a note of them. LX505/LX605 Network User Manual...
The projector does not send message to the address set in "Administrator address" text box. If you want to send e-mails to the administrator address, enter the administrator address into "Add address" text box. LX505/LX605 Network User Manual...
Page 28
Standby in proper user operation" signifies that the projector is turned on by using the web browser and then it is turned into standby with ON/STANDBY button on the top control or the remote control. Up to 99,999 hours can be set for use time. LX505/LX605 Network User Manual...
Unplug the AC power cord and plug it, and then turn on the projector once again to verify operation. If the problem still persists, unplug the AC power cord and ask servicing to a qualified service personnel with the error information. LX505/LX605 Network User Manual...
Page 30
When lamp corres. value reaches preselect use time: TITLE: Message from projector Projector Model Name: model name TCP/IP: 192.168.1.201 Projector Name: Proj05 It sends you following message. *The accumulated lamp use time has reached 2000 hours. LX505/LX605 Network User Manual...
Community name(refer) ..Enter community name (read only). Default name is "public". Trap Item ........Description Community name ...... Enter community name to send "Trap". Default name is "public". Add address ........Enter IP address of the SNMP manager computer to receive "Trap". LX505/LX605 Network User Manual...
Page 32
Standby in proper user operation" signifies that the projector is turned on by using the web browser and then it is turned into standby with ON/STANDBY button on the top control or the remote control. Up to 99,999 hours can be set for the time setting. LX505/LX605 Network User Manual...
Chapter 4 Controlling the Projector Describes controlling and setting of the projector by using the web browser. LX505/LX605 Network User Manual LX505/LX605 Network User Manual 1 Rev.1 (12 - )
Power control ..Controls the projector power by clicking the "ON" or "Standby" button. The projector cannot be turned on while the projector is on cooling down. The web browser checks and updates the projector's condition every 30 seconds automatically. LX505/LX605 Network User Manual...
Page 35
If you set this as Eco, then the network part will be turned off when you turn off the projector. Consequently, you cannot turn on/off the projector via the networks. LX505/LX605 Network User Manual...
For further information , refer to the projector's owner's manual. When the projector is in standby, all the controlling items are inactive. LX505/LX605 Network User Manual...
575p, 720p, 1035i, 1080i and 1080p. If the mode (Mode1 to Mode10, ExMode11 to ExMode60) which is stored in the item "PC Adjustment" ( p.38) is available, they are also listed together with the above mode. LX505/LX605 Network User Manual...
Item Description Volume ....Adjusts the sound volume from the speaker. (0 ~ 63) Mute ......Suppresses the sound. (ON, OFF) Built-in SP....Suppresses the built-in speaker. (ON, OFF) LX505/LX605 Network User Manual...
Image mode Video Computer Standard Cinema The mark " " means that the available image mode in the Real selected input source. The error message appears when Image1 - 10 selecting the disabled image mode indicated with "*". LX505/LX605 Network User Manual...
Mode Store ..Stores the PC adjustment values. Select a mode no. [Mode1 - Mode10] from the pull-down menu. Mode Free .... Clear the PC adjustment values. Select a mode no. [Mode1 - Mode10] from the pull- down menu. LX505/LX605 Network User Manual...
Screen mode Video Computer Normal Wide The mark " " means that the available screen mode in True the selected input source system. The error message Full appears when selecting the disabled screen mode indi- Custom cated with "*". LX505/LX605 Network User Manual...
....Selects lamp life control mode (Mode1, Mode2) when the total use time exceeds the recommended total hours of use. Remote control..Selects the remote control code. (Code1 - Code8) Fan speed control ....Sets the running speed for the cooling fans. (Normal, Max) LX505/LX605 Network User Manual...
Factory default ..Sets all of the projector control items to the factory default setting except the fol- lowing items. Lamp Corres. Value, PJ time, Network PIN code, Network setting * This function is not effective for the settings of Network address settings, e-mail settings, etc. LX505/LX605 Network User Manual...
Lamp Corres. Value(h) Displays the use time (Corresponding value) of the lamp. Filter time(h) Displays the accumulated use time of the filter. Filter condition Displays filter status with an icon. Refer to the table as shown in the next page. LX505/LX605 Network User Manual...
Page 45
Icon display/background Status Good condition. Blue Filter is almost clogged. Yellow/Gray Filter is clogged. Replace a filter with new one. * When the projector cannot decode the return from the filter cartridge, Red/Gray this icon also appears. LX505/LX605 Network User Manual...
Chapter 5 Appendix Connection examples Use of telnet Web browser setting Technical data Q & A LX505/LX605 Network User Manual LX505/LX605 Network User Manual 020-000232-01 Rev.1 (12-2009)
Default Gateway : 0.0.0.0 : 0.0.0.0 Computer Name: PC10 IP Address : 192.168.0.10 Subnet Mask : 255.255.255.0 Default Gateway : When the projector is connected to the computer directly without hub, the UTP cross cable should be used. LX505/LX605 Network User Manual...
> telnet [return] 2. The telnet application will start and the following window will be displayed. Type as below to connect the projector. > open 192.168.1.201 10000 [return] * Use the IP address assigned to the projector. LX505/LX605 Network User Manual...
Page 51
4 times continuously, the communication will be disconnected automatically. Please try again for the connection. If the password or any command is not entered for more than 30 seconds, the communication will be disconnected automatically. Please try again for the connection. LX505/LX605 Network User Manual...
There are various ways to change your browser preferences depending on the version or applica- tions. Please see the setting instructions on next page for example and also refer to on-line help of your web browser. LX505/LX605 Network User Manual...
Select Internet Options from Tools menu on the web browser and then select Security tab and click Customize Level… button. On the security setting window, scroll down and find the Scripting item, make sure that "Enable" is selected in item Active Scripting. LX505/LX605 Network User Manual...
Page 54
If you connect the projector to the computer directly with UTP cross cable, this must be unchecked. To designate proxy settings that will not use the proxy server when accessing the projector installed in the local area network, enter the IP address or domain name here. LX505/LX605 Network User Manual...
Page 55
UTP cross cable, this must be selected. To designate proxy settings that will not use the proxy server when accessing the projector installed in the local area net- work, enter the IP address or domain name here. LX505/LX605 Network User Manual...
Page 56
If you connect the projector to the computer directly with UTP cross cable, they must be unchecked. To designate proxy settings that will not use the proxy server when accessing the projector installed in the local area network, enter the IP address or domain name here. LX505/LX605 Network User Manual...
(Connect to the company’s network from the branch office or maintenance office by using private line.) Use of internet (Connect to the company’s network from your home, branch office or some other places by using the internet.) LX505/LX605 Network User Manual...
Page 58
Can I register the setting page as a web browser "Favorites" or "Bookmarks"? Please add "Login" page to your "Favorites" or "Bookmarks". Do not add the speci- fied setting page because it will not be able to perform the password authentica- tion correctly. LX505/LX605 Network User Manual...
Page 59
For further information please contact your network administrator ( p.25). It may be required for the authentication depending on the SMTP server. This projec- tor does not support this kind of SMTP server. LX505/LX605 Network User Manual...
Page 60
Can I control the projector by using the telnet application? Possible. Please refer to the item "Use of telnet" ( p.48 - 49). What is the MAC address assigned to the projector? The MAC address is displayed in "Network information" menu ( p.14). LX505/LX605 Network User Manual...
Page 61
It is possible to update the firmware through the network. It is required to have a special tool for the updating. For further information please consult your local deal- er. The version number of the firmware is indicated on the lower part of the "Initial setting" page. Version of the firmware LX505/LX605 Network User Manual...
Page 62
Whitefield Road Tokyo, 135-0063 150-872 South Korea Bangalore 560 066 PH: 81-3-3599-7481 PH:+82 2 702 1601 India FX: 81-3-3599-7482 FX: +82 2 702 1602 PH: (080) 41468941 – 48 sales-japan@christiedigital.com FX: (080) 41468949 Built-in Network User Manual for LX505/LX605 SO-KA8K...