Figure 7. Duplex Receptacle Detail
PAGE 22 — TLW-300SS WELDER/AC GENERATOR — OPERATION AND PARTS MANUAL — REV. #2 (04/07/10)
TLW-300SS — OUTPUT TERMINAL OVERVIEW
120 Volt Receptacle
One GFCI Duplex Nema 5-20R (120V, 20 Amp) receptacle
is provided on the output terminal. This receptacle can be
used anytime the generator is in operation. The receptacle
is controlled by the circuit breaker located on the control
panel.
The reset button is for the GFCI when the circuit is tripped.
Pressing the "Test Button" (See Figure 8) in the center of
this receptacle will check the GFCI function. The receptacle
should be tested at least once a month.
AUTEK MAQUINARIA 5392 7077
Figure 6. Output Terminal Panel
Figure 8. GFCI Test Button
AUTEK MAQUINARIA 5392 7077