Troubleshooting - Nexgrill 740-0593A Care And Use Manual

Stainless steel lp built-in grill
Table of Contents

Advertisement

Figure 2240
CSA International
Project 2056659
21 of 25

TROUBLESHOOTING

Please refer to the following Troubleshooting Guide if you have any problems lighting or
operating your grill.
Many solutions given here can make your grilling experience safer and more enjoyable.
Problem
Grill will not light
Burner flame is yellow and gas
odor can be smelled
Excessive flare-ups
Burner blows out
Possible Solutions
1. Push and turn the knob and check for sparks.
2. If there is a spark, check to make sure gas is supplied to the
burner.
a. Purge the line of any trapped air.
b. Check to see if you can match-light the burner.
c. Check to see that the other burners operated.
d. Visually check the electrode and wire while pushing the
igniter knob. If a spark occurs anywhere but the igniter tip,
the igniter must be replaced.
1. Check the burner inlet for obstruction, especially for spiders
and other insects.
2. Check the air shutter for proper adjustment.
3. Check for the source of gas leaks.
1. Hood up when grilling.
2. Keep knobs on low.
3. Turn one burner off if necessary.
4. Post heat grill for 10-15 minutes, this will burn off drippings.
5. Use meats containing less fat.
6. Always grill chicken on low, meat side down for 20 minutes
and turn to skin side for another 20 minutes. Follow above steps.
7. If flare up continues, move meats to warming rack until flame
settles down.
8. Never spray water on gas flames—it will destroy your grill.
1. Check for any burner defects.
2. Check for proper burner installation.
3. Make certain the fuel mixture is not too lean.
4. Make sure the gas supply is sufficient.
5. See if the LP tank is empty.
20

Advertisement

Table of Contents
loading