7.0 Initial Serial Ports Configuration
7.1 Serial Port 1 Device: ( Terminal , Modem , Printer , Aux Data )
7.2 Serial port 2 Device: ( Terminal ! , Modem , Printer , Aux Data )
7.3 Modem baud/Password B=( 9600 , 19.2k ), P-word= ___ ___ ___ ___ ___ ___ ( PASSWD )
7.4 Local Terminal/front-panel Control: ( Enabled / Disabled )
7.5 Printer baud/parity: Baud=( 9600 , 19.2 k ) ; P=( odd , even , none )
7.6 Aux Data PID [hex]: ( _________________, 1ffe )
7.7 Aux Data Baud/Parity: B=( 1200, 2400, 4800, 9600, 19.2k, 38.4k ); P=( odd , even , none )
8.0 Misc. Audio/Video Setup Parameters
8.1 PCR mode ( auto-adjust to data-rate , static ! ) -- "Auto-adjust" required with DVT2000
8.2 PCR offset [hex]: ( _____________ , 0 ! ) -- Applicable if "static" above is selected
8.3 D1 Pedestal Setup: ( Disabled, Enabled ! ) -- "Enabled" matches DVT2000
8.4 Horizontal Sync Control [hex]: ( ___________ , 74 ! ) -- 0x72 is optimum with DVT2000
8.5 A/V Sync [hex]: ( _____________ , f98e ! ) -- default value is hex for '-1650' decimal
8.6 Optional outputs home-screen alarm/warning bitmask on failure:
SPI Transport Output: ( None , Warning , Alarm ); Sync Data: ( None , Warning , Alarm )
Serial Dig Video [D1]: ( None , Warning , Alarm ); ASI Transport: ( None , Warning , Alarm )
9.0 Network Settings
9.1 COMPEL PID [hex]: ( _________ , 1026 ! ) -- Next alternate is usually 1030
9.2 Wegener CA PID [hex, if applicable]: ( _________ , 1028 ! ) -- Next alternate is usually 1032
9.3 Netcon Lock: ( Locked , Unlocked )
9.4 Shared Mode ( Shared , Protected )
9.5 COMPEL Required ( Required , Not required )
9.6 Tag Bypass: ( No ! , Yes ) -- "Yes" is also known as "ISOG-enabled"
9.7 Timeouts:
#
Description
1
Fade
2
Install
3
Carrier Search
4
No COMPEL
5
COMPEL Seek
6
Header Search
10.0 Information On Option Module Setups:
Inboard Module 1:
_______________________________________________________________________
_______________________________________________________________________
Outboard Module 2:
_______________________________________________________________________
_______________________________________________________________________
Allowed Range
0 - 30 seconds
0 - 4660 hours
0 - 4660 hours
0 - 4660 hours
0 - 4660 hours
0 - 4660 hours
E-3
Default
15 seconds !
4660 hours !
48 hours !
2 hours !
5 minutes !
48 hours !
Change from Default