3.2.7
Alarm (Red)
FLASH if any of following: (see Table 3-1, page 3-2)
1. EEPROM Boot Failure.
2. Receiver board diagnostics Boot failure.
3. Receiver board communications Boot failure.
4. Secure micro / host ID mismatch Boot failure.
ON if any of the following:
1. Receiver board run-time failure.
2. Fade mode > 10 seconds.
3. Installation mode > 10 seconds.
4. Carrier table search mode.
5. Header search mode.
6. Satellite search mode.
7. Alarming Eb/No.
8. No MPEG data > 5 seconds and locked on carrier.
9. Not authorized for current program.
10. Selected program not available.
11. Failure of an optional or special output (if allowed by factory reset control mask).
12. Overheating.
Otherwise, OFF
When an alarm or warning condition is active, that condition is displayed on the LCD. The IRD
will not indicate (neither on LED's and LCD) multiple conditions; it will indicate only the most
critical condition. Alarm conditions are considered more critical than warning conditions, and
the list of alarm and warning conditions shown above and below are listed from most critical (1)
to least critical (4 or 12).
Note that the Alarm LED is only ON when the unit is either overheating or unable to produce video, or if a
secondary output has failed (and if control mask allows for alarm or warning display).
3.2.8
Warning (Amber)
ON if any of following:
1. E-mail received but not read. (See caution, pg 3-4, and section 3.9.3, page 3-14.)
2. Secure micro run-time failure.
3. Marginal Eb/No and locked on carrier.
4. RF level is HIGH.
5. RF level is LOW.
6. Fade or Installation mode < 10 seconds.