Specifications - Vermont Castings Concord 1660 Installation And Operating Manual

The concord woodburning stove
Table of Contents

Advertisement

concord, model 1660 Series
Range of Heat Output................ 11,300 - 39,700 BTU's
Maximum heat output ..........................39,700 Btu's/hr.
Area heated ......................................Up to 1600 sq. ft.
Fuel size/type ...................................18" (457 mm) logs
Loading ...................................................... Front & Side
Chimney connector..................... 6" (152 mm) diameter
Chimney flue size .......................6" (152 mm) minimum
Flue exit position......................................... Top or Rear
Primary air ... Manually set, thermostatically maintained
Ash handling system ..................... Removable ash pan
Glass panel......................... High-temperature Infra-red
Weight .............................................................. 420 lbs.
Width (Left leg - Right leg) ....................... 29" (737 mm)
Depth (Front Plate - Flue Collar) ............. 25" (635 mm)
Height ......................................................28" (711 mm)
Drawings not to scale.
24 "
(630mm)
fig. 1
Concord dimensions.
30005102

Specifications

1
erated, the type and moisture content of the fuel used,
1
as well as the design, construction and climatic location
2,
of your home. Figures shown are based on maximum
fuel consumption obtained under laboratory conditions
and on average efficiencies.
2
conforming homes under typical winter climate condi-
tions in New England. If your home is of nonstandard
construction (e.g., unusually well insulated, not insu-
lated, built under ground, etc.) or if you live in a more
severe or more temperate climate, these figures may
not apply. Since so many variables affect performance,
consult your Vermont Castings authorized dealer to
determine realistic expectations for your home.
(635mm)
28"
(710mm)
18"
(470mm)
1128
Madison
dimensions
This value can vary depending on how the stove is op-
These values are based on operation in building code-
25"
29"
(740mm)
Vermont Castings Concord