Clearances - Vermont Castings Concord 1660 Installation And Operating Manual

The concord woodburning stove
Table of Contents

Advertisement

Vermont Castings Concord
concord 1660 Series clearance chart
Use the chart below together with the diagrams on the next page to determine the minimum clearance required for
your particular installation. In any case, it is always advisable to locate the stove as far away from walls as possible
in order to take full advantage of the radiant properties of cast iron.
Stove clearances are measured between the cast iron Top Plate of the stove and the combustible surface. Note
that the cast iron back on the Concord protrudes 5" (127 mm) out from the stovetop, and will therefore be closer to
the wall than the top of the stove.
Chimney Connector clearances are measured between the connector surface and the combustible surface. For
Double-wall Chimney Connector, use the manufacturer's clearance specification.
Use NFPA 211 default clearance or manufacturer's installation specifications for those configurations not tested.
Stove clearaNce
Top exit, no heat shields
Top exit, heat shields on stove,
no shields on single wall con-
nector
Top exit, heat shield on stove,
heat shield on single wall con-
nector
Top exit, heat shield on stove,
double wall chimney connector
Rear exit, no heat shields
Rear exit, heat shields
chimNey coNNector
clearaNce
Without Connector Heat
Shields
With Connector Heat Shields
Single-wall Connector
froNt clearaNce
to combuStibleS*
* A distance of 48" (1220 mm) must be maintained between the stove and moveable combustible items such
as drying clothes, furniture, firewood, etc.
12
uNprotected SurfaceS
parallel installation
Side
rear
b
a
24"
21"
(610 mm)
(533 mm)
g
h
21"
24"
(533 mm)
(610 mm)
N
m
22"
21"
(559 mm)
(533 mm)
S
t
16"
12"
(406 mm)
(305 mm)
y
z
18"
20"
(457 mm)
(508 mm)
cc
dd
16"
18"
(406 mm)
(457 mm)
uNprotected Surface / vertical
19" (483 mm)
uNprotected Surface / horizontal
23" (584 mm)
corner in-
parallel installation
stallation
corner
Side
c
d
21"
12"
(533 mm)
(305 mm)
j
i
12"
21"
(305 mm)
(533 mm)
p
12"
o
18"
(305 mm)
(457 mm)
u
v
18"
12"
(457 mm)
(305 mm)
aa
12"
N/a
(305 mm)
ee
12"
N/a
(305 mm)
protected Surface / vertical
protected Surface / horizontal
all iNStallatioNS
48" (1220 mm)
protected SurfaceS
corner in-
stallation
rear
corner
e
f
14"
10"
(356 mm)
(250 mm)
k
l
14"
10"
(356 mm)
(250 mm)
q
r
14"
8"
(356 mm)
(203 mm)
w
X
11"
8"
(279 mm)
(203 mm)
bb
15"
N/a
(381 mm)
ff
12"
N/a
(305 mm)
13" (330 mm)
23" (584 mm)
30005102