Filter Cycle Suspension

During a Filter cycle, if an accessory (a pump, the blower, or the light) is used manually, the Filter cycle is
suspended the time the accessories are used. Once all accessories are turned off (whether manually or by
built-in timer), the Filtration cycle remains suspended for an extra 40 minutes. When a Filtration cycle is
suspended the Filtration cycle icon will blink.

Panel Lock

It is possible to lock out all the keys. This feature is helpful when young children could have
access to the keypad. To lock/unlock the keypad, simply press on the Pump #1 key for at
least 5 seconds.
There are 2 keypad lock modes: the full lock, or the partial lock. The full lock, as the name
implies, locks ALL keypad functions. The partial lock locks only the programming functions;
the Pump, Blower, and Light keys remain useable.
To lock, press on the Pump 1 key for 5 seconds. At that point, "LocP" will be displayed. If
the key is released at this time, keypad will be in partial lock. However, if lock key is kept
pressed for another 5 seconds, "LocF" will appear and the keypad will be fully locked.
When the keypad is locked, all automatic functions of the system run as usual. However, when
a locked key is pressed, a "LocP" or "LocF" message is displayed for 1 second. Also note that
a power-up unlocks the keypad.
Invert Display
It is possible to set the display so that it is readable from either inside or outside the spa. To do
this, just press and hold the Filter Cycle button for 5 sec to toggle between the inverted and
normal modes.
Temperature displayed in Fahrenheit or Celsius
The temperature can be displayed in Fahrenheit or Celsius. To toggle between those choices,
press on light key for five seconds. Note that after a power-up the system always return to
default Fahrenheit display.
Boost Filtration mode
This mode is used to speed-up filtration after intensive use of the spas or to help mix chemical
just added in the spa. Press the Pump 2 key for 5 seconds to enable the Boost Filtration mode.
Filtration mode. In this mode, the Pump1 high speed and the ozonator will operate for 45
minutes. When Boost is enabled, a 'boo' message is displayed.