Overtemp During Filter Cycle
In order to prevent excessive water temperatures due to long Filter cycles during warm weather, the
system has a special safeguard.
If the water temperature exceeds the set point by more then 2
Filter cycle and the Filter cycle icon will blink for the remainder of the filter cycle. The Filter cycle
icon blink pattern will be: ON for 1/2 second, OFF for 1/2 second, ON for 1/2 second, then fi-
nally OFF for 1 1/2 seconds. This sequence will then repeat. The filtration cycle will automatically
reset itself once the water temperature falls below the set point.
F 01
F 01
FF04
18
18
Press on the Filter Cycle key. The display will
show Fd XX where XX represents the
number of hours Pump 1 will be operating
at low speed.
Use the Up & Down arrow keys to change
the number of hours.
00 = no filtration
01 = 1 hour/cycle
02 = 2 hour/cycle
Press the Filter Cycle Key again, enter the
duration. The display now shows the num-
ber of cycles (FFxx) where "xx" is the num-
ber of cycles in a 24 hour period. You can
select from 1 cycle to 4 cycles per day using
the arrow keys. When the desired setting is
displayed, press the Filter key to accept it. A
filter cycle will start immediately.
The Filter Cycle triangular icon will appear
on the display when a filter cycle is on.
F (1
C), the system will cancel the
o
o