Maintenance
38
Wiring Diagram
Caution:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper operation after servicing.
Comfort Control
CONTINUOUS
GREENSMART
Replacement Parts List
Caution:
Use only Travis Industries replacement parts. Do not use substitute materials.
Warning:
Do not operate appliance with the glass front removed, cracked, or broken. Replacement of
the glass should be done by a licensed or qualified service person.
Contact your local Travis Industries Dealer for a Replacement Parts List
© Travis Industries
Spark Rod
Valve
Pilot
Ground
Orange
Green
Yellow / Green
White
PILOT
PILOT
Accent
Light
Rheostat
(for authorized service personnel only)
Pilot
Sensor
IPI / CPI
Black/
Black
White
Red
Grey
Purple
(not used)
Thermodisk
Optional
Blower(s)
4121109
CN4
PILOT
DIGITAL
SENSOR
FIREPLACE
CN0
BURNER
CONTROL
SPARK ROD
DIAGNOSTIC
VALVE
COMMAND
POWER
GROUND
CN1
CN3
CN2
BURNER CONTROL
RECEIVER
Remote
Receiver
(4) AA Batteries
AC
ADAPTER
Rheostat
100-01329.docx