and work with approved safety equipment, such as those dust masks that are spe-
cially designed to filter out microscopic particles. (California Health & Safety Code
§ 25249.5, et seq.)
When unpacking, check to make sure that the item is intact and undamaged. If any
parts are missing or broken, please call Harbor Freight Tools at the number shown on the
cover of this manual as soon as possible.
1.
For best results, a regulator and in-line filters should be connected to the Brad
Nailer. (See Figure 1)
2.
Wrap the 1/4" air connector (not included) with at least four turns of pipe thread seal
tape before connecting to a 3/8" ID Air Source Hose (not included).
3.
Set the air pressure on the compressor between 50 to 120 PSI. The recommended
setting is 90 PSI. Do not exceed the maximum air pressure of 120 PSI. The amount
of air pressure used effects how deep the Brads will be driven.
4.
Check the air connection for air leaks. Disconnect the Brad Nailer, if any air leaks
are detected.
1.
Push the Release Latch (67) and slide the Magazine Assembly (73) back.
2.
Place a full clip of the appropriate length (5/8" to 2") 18-gauge Brads in the Magazine
Assembly. Up to 110 Brads can be loaded in the Magazine Assembly.