Ins Talling Chimney Components; Chimney Connector - Quadra-Fire Isle Royale 823-0170-MBK Owner's Manual

Non-catalytic, top-load, wood heater installation and operation
Hide thumbs Also See for Isle Royale 823-0170-MBK:
Table of Contents

Advertisement

Mas onry Chimney Liner ( Cont' d)
Wo o d Stu d 2 in.
( 5 1 mm)
Cl earance f ro m
chimney w al l
H ead er
F irecl ay l iner 5 / 8 in.
( 1 6 mm) M inimu m
o r E q u iv al ent.
Sil l su ppo rt
T himb l e A ssemb l y :
1 2 in. ( 3 0 5 mm) o f
b rick separatio n
b etw een cl ay l iner
and co mb u stib l es.
F igure 1 7 . 1
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer
to the owner' s information manual provided with this appli-
ance. F or assistance or additional information consult a
qualified installer, service agency or your dealer.
M arch 2 1 , 2 0 1 3
Is le Royale Wood Stov e
C. Ins talling Chimney Components

Chimney Connector

Single wall connector or stove pipe.
T his must be at least 2 4 gauge mild steel or 2 6 gauge blue
steel. T he sections must be attached to the appliance and
F irecl ay l iner 5 / 8 in.
to each other with the crimped ( male) end pointing toward
( 1 6 mm) M inimu m
o r E q u iv al ent.
the stove. All joints, including the connection at the flue
collar, should be secured with 3 sheet metal screws. M ak e
sure to follow the minimum clearances to combustibles.
W here passage through the wall, or partition of combustible
construction is desired in C anada, the installation shall
conform to CAN/CSA-B365.
F actory- built listed chimney connector ( vented) .
A listed connector (vented) must be used when installing
this unit in a mobile home. T he listed connectors must
conform to each other to ensure a proper fit and seal.
2 5 0 - 5 7 6 3 F
Crimped
End
Toward
Stove
Secure pipe sections with a
minimum of 3 screws
F igure 1 7 . 2
Chimney Connector ( Stov e P ipe)
WARNING
F ire Ris k .
F ollow C himney C onnector M anufacturer' s
Instructions for P roper Installation.
ONLY use connector:
Within the room, between appliance and ceiling or wall.
C onnector shall NO T pass through:
Attic or roof space
Closet or similar concealed space
Floor or ceiling
M aintain minimum clearances to combustibles
R
Flue Gas
Direction
P age 1 7