When 2P is selected:
1
Press s to select 2P White Balance �
2
Press s or r to select Red-Offset , Green-Offset ,
Blue-Offset , Red-Gain , Green-Gain or Blue-
Gain
3
Press v or w to adjust the settings as desired�
When 10P is selected:
1
Press s to select 10P White Balance �
2
Press s or r to select IRE (white level), Red ,
Green or Blue �
3
Press v or w to adjust the settings as desired�
Colour Calibration
The aim of Colour Calibration is to measure and/or adjust
the colour response(White Balance) of your LCD panel�
Colour Calibration is used by various fields, such as
gaming, photography, engineering, medical and more� In
order to calibrate a display correctly, you need a colour
analyzer TPA-1 (not supplied)�
Apply Calibration
1
From the Expert Picture Settings menu, press s
or r to select Colour Calibration and press OK �
2
Press s or r to select Apply Calibration and press
v or w to select Enable or Disable �
Manual Colour Calibration
1
From the Colour Calibration menu, press s or r
to select Manual Colour Calibration and press OK �
Manual Colour Calibration
Please input the value measured with the colour analyser.
x
y
Red
0.640
0.330
Green
0.300
0.600
Blue
0.150
0.060
Start
Reset
2
Place the prove of the colour analyzer over the square
on screen to measure�
3
Input the value measured with the colour analyzer
using the Number buttons (0-9)�
Red
Green
Blue
Using the TV's features (General)
x
y
0.640
0.330
0.300
0.600
0.150
0.060
4
Press s , r , v or w and input the values to fill all
RGBxy matrix table�
5
Highlight Start and press OK � Please wait until you
see "Manual Colour Calibration has been completed"
on screen�
To return to factory setting
Select Reset and press OK �
Auto Colour Calibration
1
From the Colour Calibration menu, press s or r
to select Auto Colour Calibration and press OK �
2
Place the prove of the USB colour analyzer over the
square on screen and connect USB colour analyzer for
the USB1 or USB2 port, and press OK � Auto Colour
Calibration will start� Please wait until you see " Auto
Colour Calibration has been completed"�
Gamma Calibration
1
In the Expert Picture Settings menu , press s or
r to select Gamma Calibration and press OK �
2
Press s or r to select Apply Calibration and press
v or w to select Enable or Disable �
3
Press s or r to select Auto Gamma Calibration
and press OK �
4
Input the target value and place the USB colour
analyzer over the square on screen and, connect USB
colour analyzer for theUSB1 or USB2 port�
Auto Gamma Calibration
Please input the target value and place the USB colour analyser over the square.
Target Colour Temperature
0.313
Target Gamma
Start
5
Select Start and press OK � Auto Gamma Calibration
will start� Please wait until you see "Auto Gamma
Calibration has been completed" on screen�
To return to factory setting
Select Reset and press OK �
Resetting the Expert Picture Settings
This feature resets your Expert Picture Settings to the
factory settings�
x
y
0.329
(D65)
2.4
Reset
27