Carrier 38YRA Product Data page 33

60hz heat pump outdoor sections
Table of Contents

Advertisement

Heat pump heating performance continued
INDOOR
AIR
–3
Capacity
Total
(MBtuh)
Power
EDB
CFM
Total
Int*
Kw† Total
1100 16.0
14.7
2.43
1200 16.2
14.9
2.46
65
1300 16.4
15.1
2.48
1100 15.7
14.5
2.52
1200 15.9
14.6
2.55
70
1300 16.1
14.8
2.57
1100 15.4
14.1
2.62
1200 15.6
14.3
2.64
75
1300 15.7
14.5
2.67
Indoor
Section
Size
FC4BN(F,B)
042
FC4BNF
033
036
F(A,B)4ANF
036
F(A,B)4AN(F,B)
042
FG3AAA
036
FK4BNF
001
002
003
004
FK4CNF
001
002
003
CD5A/CD5BW
036
CC5A/CD5A/CD5BA
036
042
043
CC5A/CD5A/CD5BW
042
043
CD3(A,B)A
036
042
CE3AA
036
042
CF5AA
036
CJ5A/CK5A/CK5BA
036
042
CJ5A/CK5A/CK5BN
042
CJ5A/CK5A/CK5BW
036
CK3BA
036
042
COILS + 58MVP040-14 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
042
CD3(A,B)A
042
CJ5A/CK5A/CK5BA
042
CJ5A/CK5A/CK5BW
036
CK3BA
036
042
COILS + 58MVP060-14 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
042
CD3(A,B)A
042
CJ5A/CK5A/CK5BA
036
See notes on pg. 37.
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
7
17
Capacity
Total
Capacity
(MBtuh)
Power
(MBtuh)
Int*
Kw† Total
Int*
38YRA036-31 Outdoor Section With FC4BN(F,B)042 Indoor Section
19.3
17.7
2.53
22.8
20.8
19.4
17.9
2.55
23.0
21.0
19.7
18.1
2.58
23.2
21.1
19.1
17.5
2.64
22.6
20.6
19.2
17.7
2.66
22.8
20.8
19.4
17.8
2.68
23.0
20.9
18.9
17.3
2.74
22.4
20.4
19.0
17.5
2.76
22.6
20.6
19.2
17.6
2.78
22.7
20.7
Multipliers for Determining the Performance With Other Indoor Sections
Heating
Capacity
Power
1.00
1.00
1.00
1.00
1.00
1.03
1.00
1.03
1.00
1.00
1.00
1.03
1.00
1.00
1.00
0.97
0.99
0.94
1.00
0.92
0.98
0.99
0.99
0.97
0.98
0.94
1.00
1.01
1.00
1.01
1.00
1.01
1.00
1.01
1.00
1.02
1.00
1.01
1.00
1.01
1.00
1.01
1.00
1.02
1.00
0.99
1.00
1.01
1.00
1.01
1.00
0.99
1.00
0.99
1.00
1.01
1.00
1.01
1.00
0.99
1.00
0.98
1.00
0.98
1.00
0.97
1.00
0.98
1.00
0.98
1.00
0.97
1.00
0.98
1.00
0.98
1.00
0.98
27
Total
Capacity
Total
Capacity
Power
(MBtuh)
Power
(MBtuh)
Kw† Total
Int*
Kw† Total
2.64
26.7
23.7
2.74
31.2
2.65
26.9
23.9
2.75
31.4
2.66
27.1
24.1
2.76
31.6
2.75
26.5
23.5
2.87
30.9
2.76
26.7
23.7
2.87
31.1
2.78
26.9
23.9
2.88
31.3
2.87
26.2
23.3
2.99
30.6
2.88
26.4
23.5
3.00
30.8
2.89
26.6
23.6
3.01
31.0
Indoor
Section
CJ5A/CK5A/CK5BN
CK3BA
COILS + 58MVP080-14 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CD3(A,B)A
CJ5A/CK5A/CK5BA
CJ5A/CK5A/CK5BW
CK3BA
COILS + 58MVP100-20 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CD3(A,B)A
CJ5A/CK5A/CK5BA
CJ5A/CK5A/CK5BW
CK3BA
COILS + 58MVP120-20 VARIABLE-SPEED FURNACE
CJ5A/CK5A/CK5BA
CJ5A/CK5A/CK5BW
CK3BA
COILS + 58U(H,X)V060-12 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CC5A/CD5A/CD5BW
CD3(A,B)A
CC5A/CD5A/CD5BC
CE3AA
CJ5A/CK5A/CK5BA
CK3BA
COILS + 58U(H,X)V080-16 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CC5A/CD5A/CD5BW
CD3(A,B)A
CC5A/CD5A/CD5BC
CE3AA
CJ5A/CK5A/CK5BA
CJ5A/CK5A/CK5BW
CK3BA
37
47
Total
Capacity
Total
Power
(MBtuh)
Power
Int*
Kw† Total
Int*
Kw† Total
28.4
2.87
36.1
36.1
3.03
28.6
2.87
36.4
36.4
3.03
28.7
2.88
36.6
36.6
3.03
28.1
3.00
35.7
35.7
3.17
28.3
3.00
36.0
36.0
3.16
28.5
3.01
36.2
36.2
3.16
27.8
3.14
35.4
35.4
3.31
28.0
3.14
35.6
35.6
3.30
28.2
3.14
35.9
35.9
3.30
Heating
Size
Capacity
042
1.00
036
1.00
042
1.00
042
0.99
042
0.99
042
1.00
036
1.00
036
1.00
042
1.00
042
0.99
042
0.99
042
0.99
036
1.00
036
1.00
042
0.99
042
0.99
036
0.99
036
0.99
042
0.99
042
0.98
042
0.98
042
0.98
048
0.98
042
0.99
036
0.99
036
0.99
042
0.98
042
0.98
042
0.98
048
0.97
042
0.98
042
1.00
036
0.98
036
0.98
042
1.00
57
Capacity
Total
(MBtuh)
Power
Int*
Kw†
41.8
41.8
3.23
42.1
42.1
3.22
42.4
42.4
3.22
41.3
41.3
3.37
41.6
41.6
3.36
41.9
41.9
3.35
40.9
40.9
3.52
41.2
41.2
3.50
41.5
41.5
3.50
Power
0.97
0.98
0.97
0.97
0.97
0.97
0.98
0.98
0.97
0.97
0.97
0.95
0.96
0.96
0.95
0.95
0.95
0.95
0.95
0.98
0.98
0.98
1.00
0.97
0.97
0.97
0.96
0.96
0.96
0.98
0.95
0.96
0.95
0.95
0.96
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents