Table of Contents

Advertisement

Detailed cooling capacities* continued
EVAPORATOR
AIR
Capacity
MBtuh†
CFM
EWB
Total
72
53.2
67
48.9
1260
63††
45.8
62
45.0
57
42.9
72
54.1
67
49.8
1400
63††
46.4
62
45.8
57
44.5
72
54.8
67
50.6
1610
63††
47.2
62
46.8
57
46.3
Indoor
Section
Size
F(A,B)4AN(F,B,C)
048
060
FB4ANB
070
FC4BN(F,B)
048
060
FC4BNB
054
070
FG3AAA
048
060
FK4BNB
006
FK4CNB
006
FK4CNF
005
CC5A/CD5A/CD5BA
060
CC5A/CD5A/CD5BC
048
CC5A/CD5A/CD5BW
048
060
CD3(A,B)A
048
060
CD5A/CD5BA
048
CE3AA
048
060
CF5AA
048
CJ5A/CK5A/CK5BA
048
060
CJ5A/CK5A/CK5BN
060
CJ5A/CK5A/CK5BW
048
CJ5A/CK5A/CK5BX
060
CK3BA
048
060
COILS + 58MVP040-14 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
060
CC5A/CD5A/CD5BW
060
CD3(A,B)A
060
COILS + 58MVP060-14 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
060
CC5A/CD5A/CD5BW
060
CD3(A,B)A
060
See notes on pg. 28.
26
CONDENSER ENTERING AIR TEMPERATURES °F
85
Capacity
Total
MBtuh†
System
Sens‡
Total
Kw**
38YRA048-30 Outdoor Section With FK4CNF005 Indoor Section
26.3
4.00
51.1
32.9
3.96
46.7
32.2
3.93
43.7
39.5
3.93
43.0
42.9
3.90
41.5
27.3
4.05
51.7
34.6
4.01
47.5
33.7
3.97
44.4
41.7
3.97
43.7
44.5
3.96
42.8
28.6
4.11
52.4
36.9
4.06
48.4
35.8
4.03
45.3
44.8
4.03
44.9
46.3
4.03
44.4
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Capacity
Power
0.96
1.05
0.99
1.07
1.00
1.06
0.96
1.05
0.99
1.07
1.01
1.04
1.00
1.06
0.95
1.04
0.97
1.04
1.01
1.00
1.01
0.98
1.00
1.00
0.95
1.04
0.94
1.04
0.95
1.04
0.98
1.04
0.95
1.04
0.95
1.04
0.95
1.04
0.96
1.04
0.98
1.04
0.96
1.04
0.94
1.04
0.96
1.04
0.96
1.04
0.94
1.04
0.98
1.04
0.94
1.04
0.96
1.04
0.95
1.03
0.97
1.03
0.95
1.03
0.95
1.02
0.97
1.02
0.95
1.02
95
Capacity
Total
MBtuh†
System
Sens‡
Total
Kw**
25.5
4.51
48.6
32.0
4.45
44.4
31.3
4.42
41.5
38.5
4.41
40.9
41.5
4.40
39.8
26.4
4.55
49.0
33.7
4.50
45.1
32.8
4.47
42.2
40.7
4.45
41.5
42.8
4.44
41.0
27.7
4.61
49.7
36.0
4.57
45.9
35.0
4.54
43.0
43.8
4.53
42.7
44.4
4.52
42.7
Indoor
Section
COILS + 58MVP080-14 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CC5A/CD5A/CD5BW
CD3(A,B)A
COILS + 58MVP100-20 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CC5A/CD5A/CD5BW
CD3(A,B)A
CJ5A/CK5A/CK5BA
CJ5A/CK5A/CK5BN
CJ5A/CK5A/CK5BX
CK3BA
COILS + 58MVP120-20 VARIABLE-SPEED FURNACE
CJ5A/CK5A/CK5BA
CJ5A/CK5A/CK5BW
CJ5A/CK5A/CK5BX
CK3BA
COILS + 58U(H,X)V080-16 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CC5A/CD5A/CD5BW
CD3(A,B)A
CE3AA
CJ5A/CK5A/CK5BA
CK3BA
COILS + 58U(H,X)V100-20 VARIABLE-SPEED FURNACE
CC5A/CD5A/CD5BA
CC5A/CD5A/CD5BW
CD3(A,B)A
CE3AA
CJ5A/CK5A/CK5BA
CJ5A/CK5A/CK5BW
CJ5A/CK5A/CK5BX
CK3BA
105
Capacity
Total
MBtuh†
System
Sens‡
Total
Kw**
24.6
5.0
46.0
31.1
4.9
42.0
30.3
4.9
39.5
37.5
4.9
38.7
39.8
4.9
38.0
25.4
5.0
46.3
32.7
5.0
42.6
31.8
5.0
40.1
39.6
4.9
39.6
41.0
4.9
39.1
26.8
5.1
46.6
35.1
5.1
43.4
34.0
5.0
40.6
42.5
5.0
40.7
42.7
5.0
40.7
Cooling
Size
Capacity
060
0.95
060
0.97
060
0.95
060
0.95
060
0.98
060
0.95
060
0.98
060
0.98
060
1.00
060
0.98
060
0.98
048
0.96
060
0.99
048
0.96
060
0.98
060
0.95
060
0.98
060
0.95
060
0.98
048
0.95
048
0.95
060
0.96
060
0.96
060
0.98
060
0.96
060
0.99
060
0.97
048
0.96
060
0.99
048
0.96
060
0.97
115
Total
System
Sens‡
Kw**
23.6
5.65
30.1
5.56
29.4
5.53
36.5
5.50
38.0
5.49
24.5
5.68
31.7
5.62
30.9
5.58
38.6
5.57
39.1
5.55
25.7
5.73
34.1
5.69
33.0
5.64
40.7
5.65
40.7
5.64
Power
1.01
1.01
1.01
1.00
1.00
1.00
1.06
1.06
1.00
1.06
1.05
1.05
1.04
1.05
1.05
1.00
1.00
1.00
1.01
1.02
1.02
1.02
0.98
0.98
0.98
0.99
0.99
0.99
0.99
0.99
0.99

Hide quick links: