Fg3Aaa060; F(A,B)4An(F,B)060; Fb4Anb070 - Carrier 38YRA Product Data

60hz heat pump outdoor sections
Table of Contents

Advertisement

Combination ratings* continued
UNIT SIZE-
SERIES
AND
SOUND
RATING
INDOOR
(dBA)
UNIT
FK4CNB006†

F(A,B)4AN(F,B)060

FB4ANB070

FC4BN(F,B)060
FC4BNB070

FG3AAA060

FK4BNB006
CC5A/CD5A/CD5BA060
CC5A/CD5A/CD5BW060
CD3(A,B)A060
CE3AA060
CJ5A/CK5A/CK5BA060
CJ5A/CK5A/CK5BN060
CJ5A/CK5A/CK5BX060
CK3BA060
060-30
CC5A/CD5A/CD5BA060
CD3(A,B)A060
CC5A/CD5A/CD5BW060
75
CC5A/CD5A/CD5BA060
CD3(A,B)A060
CC5A/CD5A/CD5BW060
CE3AA060
CJ5A/CK5A/CK5BA060
CJ5A/CK5A/CK5BX060
CK3BA060
CC5A/CD5A/CD5BA060
CD3(A,B)A060
CC5A/CD5A/CD5BW060
CE3AA060
CJ5A/CK5A/CK5BA060
CJ5A/CK5A/CK5BX060
CK3BA060
* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard: 80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.
High-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.
Low-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 17°F (-9°C) db 15°F (–10°C) wb air entering outdoor unit.
† Outdoor section/indoor section combination tested in accordance with DOE test procedures for heat pumps. Ratings for other combinations are determined
under DOE computer simulation procedures.
‡ Requires hard shutoff TXV; based on computer simulation.
** TDR is on all furnaces, except 58GFA.
SEER — Seasonal Energy Efficiency Ratio
COP — Coefficient of Performance
HSPF — Heating Seasonal Performance Factor
TC — Total Capacity (Btuh)
16
Cooling
Seasonal Efficiency SEER
Factory-
Supplied
Enhance-
Standard
TC
ment
Rating
59,000
TDR & TXV
12.50
57,500
TDR
58,500
TDR
57,500
TDR & TXV
11.50
58,500
TDR & TXV
12.00
56,500
None
59,000
TDR & TXV
12.50
55,500
None
56,500
None
55,500
None
57,500
None
57,500
None
57,500
None
58,000
None
57,500
None
COILS + 58MVP100-20 VARIABLE-SPEED FURNACE
55,000
TDR
55,000
TDR
56,500
TDR
COILS + 58U(H,X)V100-20 VARIABLE-SPEED FURNACE
55,500
TDR
55,500
TDR
57,000
TDR
57,500
TDR
57,500
TDR
58,500
TDR
57,500
TDR
COILS + 58U(H,X)V120-20 VARIABLE-SPEED FURNACE
55,000
TDR
55,000
TDR
56,500
TDR
57,500
TDR
57,500
TDR
58,000
TDR
57,500
TDR
LSV — Liquid Solenoid Valve
TDR — Time-Delay Relay
TXV — Thermostatic Expansion Valve
ARI STANDARD RATINGS*
Field-Supplied
High-Temp
Accessory‡
TC
TXV
TXV&TDR**
61,000
11.50
61,000
12.00
61,000
61,000
61,000
11.50
61,000
61,000
11.50
61,000
11.50
61,000
11.50
61,000
12.00
61,000
11.50
61,000
11.50
61,000
12.00
61,000
11.50
61,000
11.20
61,000
11.20
61,000
11.50
61,000
11.50
61,000
11.50
61,000
12.00
61,000
12.00
61,000
12.00
61,000
12.20
61,000
12.00
61,000
11.50
61,000
11.50
61,000
12.00
61,000
12.00
61,000
11.80
61,000
12.00
61,000
11.80
61,000
Heating
Low-Temp
Seasonal
Efficiency
HSPF/HSPF
COP
TC
COP
3.32
39,000
2.58
3.06
39,500
2.40
3.22
39,500
2.48
3.06
39,500
2.40
3.22
39,500
2.48
2.94
39,000
2.36
3.30
39,000
2.54
2.82
38,500
2.30
3.00
39,000
2.40
2.82
38,500
2.30
3.00
39,000
2.40
2.94
39,000
2.38
2.94
39,000
2.38
3.08
39,000
2.44
2.94
39,000
2.38
2.80
39,500
2.30
2.80
39,500
2.30
3.00
39,500
2.40
2.84
38,500
2.32
2.84
38,500
2.32
3.04
39,000
2.44
3.02
39,000
2.42
2.94
38,500
2.40
3.12
38,500
2.48
2.94
38,500
2.40
2.80
39,000
2.30
2.80
39,000
2.30
3.02
39,000
2.42
3.00
39,000
2.42
2.96
38,500
2.38
3.10
38,500
2.46
2.96
38,500
2.38
with LSV
8.30/8.50
7.80/8.20
8.00/8.20
7.80/8.00
8.00/8.20
7.50/7.70
8.30/8.50
7.30/7.50
7.70/7.90
7.30/7.50
7.70/7.90
7.50
7.50
7.80
7.50
7.20/7.40
7.20/7.40
7.50/7.70
7.20/7.40
7.20/7.40
7.80/8.00
7.80/8.00
7.50
7.80
7.50
7.20/7.40
7.20/7.40
7.50/7.70
7.50/7.70
7.50
7.80
7.50

Hide quick links: