Braeburn 2000 User Manual

Braeburn 2000 User Manual

Builder series 5-2 day programmable single stage heat/cool digital thermostat
Hide thumbs Also See for 2000:

Advertisement

MODEL
2000
USER MANUAL
Compatible with low voltage single stage gas,
oil or electric heating or cooling systems,
including single stage heat pumps. This
thermostat can also be used on 250mv to
750mv millivolt heating only systems. Do not
use this thermostat on applications with
voltages above 30 Volts AC.
READ ALL INSTRUCTIONS BEFORE PROCEEDING
CONTENTS
1

SPECIFICATIONS

2

INSTALLATION

3
TESTING YOUR NEW THERMOSTAT
4
PROGRAMMING
5
ADDITIONAL OPERATION FEATURES
6
TROUBLESHOOTING
7
WIRING DIAGRAMS
© 2005 Braeburn Systems LLC • Patents Pending • All Rights Reserved.
Builder Series
5-2 Day Programmable
Single Stage Heat/Cool
Digital Thermostat
Pub. No. 2000-100-005
WARNING!
Important Safety Information
• Always turn off power to the air conditioning or heating system prior to installing,
removing, cleaning or servicing thermostat.
• Read this manual thoroughly prior to installing, programming or operating
this thermostat.
• This thermostat is designed for use with a 24 Volt-AC low voltage single stage
gas, oil or electric heating or cooling systems.
• Do not use this thermostat on applications with voltages above 30 Volts AC.
• This thermostat requires two (2) properly installed "AA" alkaline batteries to
provide power for the thermostat to properly control the system operation.
• Wiring must conform to all building codes and ordinances as required by local and
national code authorities having jurisdiction.
• Do not short (or jumper) across terminals on the gas valve or at the heating or
cooling system control board to test the thermostat installation. This could
damage the thermostat and void the warranty.
• Do not select COOL mode of operation if the outside temperature is below 50˚ F
(10˚ C). This could possibly damage the controlled cooling system and may cause
personal injury.
• This thermostat should only be used as described in this manual. Any other use is
not recommended and will void the warranty.
1
SPECIFICATIONS
• Electrical Rating: 24 Volt AC (18-30 Volt AC)
1 amp maximum load per terminal
2 amp total maximum load (all terminals)
• Control Range: 45˚ - 90˚ F (7˚ - 32˚ C)
• Accuracy: +/- 1˚ F (+/- .5˚ C)
• DC Power: 3.0 Volt DC (2 AA Alkaline batteries included)
• Compatibility: Compatible with low voltage single stage gas, oil or electric
heating or cooling systems, including single stage heat pumps. This thermostat
can also be used on 250mv to 750mv millivolt heating only systems.
• Terminations: Rc, Rh, G, W, Y, B, O
2
INSTALLATION
Replacing Existing Thermostat
2.1
1. Always turn off power to the air conditioning or heating system prior to removing
existing thermostat.
2. Remove the cover of your old thermostat and locate the wire terminals. Do not
remove wires from terminals yet.
3. Using small pieces of masking tape, label wires prior to removal from terminals. Use
the chart below to determine the new terminal designations for your new thermostat.
Old Terminal from
New Terminal for
Existing Thermostat
New Thermostat
V or Rc
Rc
M, 4, Rh, or R
Rh
G or F
G
H, W or 4
W
Y
Y
B
B
O
O
C
None-Cap the wire
Terminal Description
Cooling Transformer
Heating Transformer
Fan Control
Heating Control
Cooling Control
Reversing Valve (Heating)
Reversing Valve (Cooling)
24 Volt AC, Transformer Common
1

Advertisement

Table of Contents
loading

Summary of Contents for Braeburn 2000

  • Page 1: Installation

    G or F Fan Control H, W or 4 Heating Control Cooling Control Reversing Valve (Heating) Reversing Valve (Cooling) None-Cap the wire 24 Volt AC, Transformer Common © 2005 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 2000-100-005...
  • Page 2: Testing Your New Thermostat

    INSTALLATION INSTALLATION cont. Replacing Existing Thermostat cont. 19. Using your finger, gently flip the switch towards the NORM NON-HP or HP selection which indicates the low voltage heating system the thermostat will control. 4. After labeling and removing all wires from terminals, unscrew the existing thermostat 20.
  • Page 3: Programming

    PROGRAMMING PROGRAMMING cont. NOTE: Default Thermostat Settings Once you have finished setting the temperature differential, you can wait 15 seconds and the thermostat will automatically return to the normal operation mode. Function Status After Reset Otherwise, you can press the RETURN button to set the extended hold time. Operation Mode Normal Operating Mode Temperature Hold...
  • Page 4: Programming Overview

    ADDITIONAL PROGRAMMING OPERATION FEATURES cont. Setting Your Energy Saving Programs cont. Review Set Temperature 1. Press and hold the button. The current setpoint temperature will be displayed in 4.4.1 Programming Overview the place of the current room temperature, and the indicator SET TEMP will be displayed. Your thermostat contains separate Weekday and Weekend Program Groups that allow you to 2.
  • Page 5 ADDITIONAL ADDITIONAL OPERATION FEATURES OPERATION FEATURES cont. cont. Low Temperature "Freeze" Protection Adaptive Recovery Mode (ARM™) In order to maximize comfort and energy efficiency, this thermostat is equipped with an While the thermostat is in the HEAT mode of operation, on standard heating (non-heat pump) applications, the thermostat will mechanically initiate a call for heat if the room temperature Adaptive Recovery Mode (ARM™).
  • Page 6: Troubleshooting

    TROUBLESHOOTING TROUBLESHOOTING cont. SYMPTOM POTENTIAL SOLUTION SYMPTOM POTENTIAL SOLUTION Thermostat does not Check to see if OFF is shown in display. This indicates that the Low battery indicator Replace batteries immediately to maintain proper system system is turned off at the thermostat. Move the system selector turn on heating or operation.
  • Page 7: Wiring Diagrams

    TROUBLESHOOTING WIRING DIAGRAMS cont. Typical 2-Wire 24 Volt AC or 250mV - 750mV Millivolt Heating Systems SYMPTOM POTENTIAL SOLUTION Thermostat will not This is above the normal thermostat temperature setting range of 45˚ to 90˚ F (7˚ to 32˚ C). allow me to program Factory Installed Jumper...
  • Page 8 Montgomery, IL 60538 Braeburn Systems LLC 2215 Cornell Avenue • Montgomery, IL 60538 Technical Assistance: www.braeburnonline.com Call us toll-free: 866-268-5599 (U.S. Only) 630-844-1968 (Outside the U.S.) © 2005 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 2000-100-005...