Builder series 5-2 day programmable multi-stage 2 heat/1 cool heat pump digital thermostat
Hide thumbs Also See for Builder 2200:

Advertisement

MODEL
2200
USER MANUAL
Compatible with low voltage multi stage
heat/cool systems with up to two stages of
heating and one stage of cooling. Do not use
this thermostat on applications with voltages
above 30 Volts AC.
READ ALL INSTRUCTIONS BEFORE PROCEEDING
CONTENTS
1

SPECIFICATIONS

2
INSTALLATION
3
TESTING YOUR NEW THERMOSTAT
4
PROGRAMMING
5
ADDITIONAL OPERATION FEATURES
6
TROUBLESHOOTING

WIRING DIAGRAMS

7
© 2005 Braeburn Systems LLC • Patents Pending • All Rights Reserved.
Builder Series
5-2 Day Programmable
Multi-Stage 2 Heat/1 Cool
Heat Pump Digital Thermostat
Pub. No. 2200-100-004
WARNING!
Important Safety Information
• Always turn off power to the air conditioning or heating system prior to installing,
removing, cleaning or servicing thermostat.
• Read this manual thoroughly prior to installing, programming or operating
this thermostat.
• This thermostat is designed for use with 24 Volt-AC low voltage multi-stage
heat pump systems.
• Do not use this thermostat on applications with voltages above 30 Volts AC.
• This thermostat requires two (2) properly installed "AA" alkaline batteries to
maintain system clock during power outages.
• The system must have 24 Volt AC power present for proper system operation
and control.
• Wiring must conform to all building codes and ordinances as required by local and
national code authorities having jurisdiction.
• Do not short (or jumper) across terminals at the heating or cooling system control
board to test the thermostat installation. This could damage the thermostat and
void the warranty.
• Do not select COOL mode of operation if the outside temperature is below 50˚ F
(10˚ C). This could possibly damage the controlled cooling system and may cause
personal injury.
• This thermostat should only be used as described in this manual. Any other use is
not recommended and will void the warranty.
1
SPECIFICATIONS
• Electrical Rating: 24 Volt AC (18-30 Volt AC)
1 amp maximum load per terminal
3 amp total maximum load (all terminals)
• Control Range: 45˚ - 90˚ F (7˚ - 32˚ C)
• Accuracy: +/- 1˚ F (+/- .5˚ C)
• AC Power: 18-30 Volts AC
• DC Back-Up Power: 3.0 Volts DC (2 AA alkaline batteries included)
• Compatibility: Multi-stage heat pump systems with up to two stages of heating
and one stage of cooling.
• Terminations: R, O, B, C, Y, E, G, W2
2
INSTALLATION
Replacing Existing Thermostat
2.1
1. Always turn off power to the air conditioning or heating system prior to removing
existing thermostat.
2. Remove the cover of your old thermostat and locate the wire terminals. Do not remove
wires from terminals yet.
3. Using small pieces of masking tape, label wires prior to removal from terminals. Use
the chart below to determine the new terminal designations for your new thermostat.
Old Terminal from
New Terminal for
Existing Thermostat
New Thermostat
R, V-VR or VR-R
R
B
O
O
B
C
C
Y, Y1 or M
Y
W, E or W1
E
G or F
G
W1, W2 or W-U
W2
Terminal Description
24 VAC
Reversing Valve (Cooling)
Reversing Valve (Heating)
24 VAC common
1st Stage Heat / Cool
Emergency Heat
Fan Control
2nd Stage Heating
1

Advertisement

loading

Summary of Contents for Braeburn Builder 2200

  • Page 1: Specifications

    Y, Y1 or M 1st Stage Heat / Cool W, E or W1 Emergency Heat G or F Fan Control W1, W2 or W-U 2nd Stage Heating © 2005 Braeburn Systems LLC • Patents Pending • All Rights Reserved. Pub. No. 2200-100-004...
  • Page 2: Installation

    TESTING YOUR INSTALLATION NEW THERMOSTAT cont. Replacing Existing Thermostat cont. WARNING! Read BEFORE Testing 4. After labeling and removing all wires from terminals, unscrew the existing thermostat • Do not short (or jumper) across terminals on the heating or cooling system sub-base from wall.
  • Page 3 PROGRAMMING PROGRAMMING cont. cont. Setting Current Time of Day and Day of Week Setting Thermostat User Options cont. NOTE: It is important for you to set the current time of day (note AM/PM indicator in Setting the Extended Hold Time (see also section 5.3) 4.3.2 display), and the current day of week correctly to avoid problems with program execution.
  • Page 4: Additional Operation Features

    ADDITIONAL PROGRAMMING OPERATION FEATURES cont. Review Set Temperature Setting Your Energy Saving Programs cont. 1. Press and hold the button. The current setpoint temperature will be displayed in the 4.4.1 Programming Overview place of the current room temperature, and the indicator SET TEMP will be displayed. Your thermostat contains separate Weekday and Weekend Program Groups that allow you to 2.
  • Page 5: Troubleshooting

    ADDITIONAL ADDITIONAL OPERATION FEATURES OPERATION FEATURES cont. cont. Compressor Protection Filter Check Monitor (see section 4.3.3 for setting) This thermostat includes an automatic compressor protection feature to avoid potential damage The Filter Check Monitor displays a reminder for required filter replacement or cleaning, by to the compressor from short cycling.
  • Page 6 TROUBLESHOOTING TROUBLESHOOTING cont. cont. SYMPTOM POTENTIAL SOLUTION SYMPTOM POTENTIAL SOLUTION Thermostat display It is possible that AC power is not present at the thermostat and Thermostat will not Check current time of day, day of week program settings. Make the back-up batteries are fully discharged. Check fuse, circuit is blank.
  • Page 7: Wiring Diagram

    Braeburn installation and operating instructions. Emergency Heat on units without separate Emergency Heat and Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat Auxiliary Heat terminals. under warranty provided it is returned postage prepaid to our warranty facility in a padded 2.